Mazda MX-5 Miata / Grand Touring. Manual — part 138
Specifications)
Courtesy of MAZDA MOTORS CORP.
Removal Order Of Variable Intake Air Solenoid Valve
VARIABLE INTAKE AIR SOLENOID VALVE INSPECTION [LF]
AIRFLOW INSPECTION
1. Remove the battery cover
2. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [LF] .)
3. Remove the variable intake air solenoid valve. (See VARIABLE INTAKE AIR SOLENOID VALVE
REMOVAL/INSTALLATION [LF] .)
4. Inspect airflow between the ports under the following conditions.
If not as specified, replace the variable intake air solenoid valve.
If as specified, carry out the Circuit Open/Short Inspection .
Fig. 17: Variable Intake Air Solenoid Valve Continuity Check Table
Courtesy of MAZDA MOTORS CORP.
1
Connector
2
Vacuum hose
3
Variable Intake air solenoid valve
NOTE:
Perform the following inspection only when directed.
2008 Mazda MX-5 Miata Grand Touring
2008 ENGINE PERFORMANCE Intake Air System - MX-5 Miata
Fig. 18: Identifying Variable Intake Air Solenoid Valve Ports
Courtesy of MAZDA MOTORS CORP.
CIRCUIT OPEN/SHORT INSPECTION
1. Disconnect the PCM connector. (See PCM REMOVAL/INSTALLATION [LF] .)
2. Inspect the following wiring harness for open or short (continuity check).
2008 Mazda MX-5 Miata Grand Touring
2008 ENGINE PERFORMANCE Intake Air System - MX-5 Miata
Fig. 19: Identifying Variable Intake Air Solenoid Valve, Main Relay & PCM Connector Terminals
Courtesy of MAZDA MOTORS CORP.
Open Circuit
If there is no continuity, the circuit is open. Repair or replace the wiring harness.
Variable intake air solenoid valve terminal B and PCM terminal 2J
Variable intake air solenoid valve terminal A and main relay
Short Circuit
2008 Mazda MX-5 Miata Grand Touring
2008 ENGINE PERFORMANCE Intake Air System - MX-5 Miata
If there is continuity, the circuit is shorted. Repair or replace the wiring harness.
Variable tumble solenoid valve terminal B and power supply
Variable tumble solenoid valve terminal B and body ground
Variable tumble solenoid valve terminal A and body ground
VARIABLE TUMBLE SHUTTER VALVE ACTUATOR INSPECTION [LF]
1. Remove the service hole cover. (See EGR VALVE REMOVAL/INSTALLATION [LF] .)
2. Disconnect the vacuum hose from the variable tumble solenoid valve.
3. Connect a vacuum pump to the vacuum hose.
4. Apply vacuum and verify that the rod moves.
If the rod does not move, replace the variable tumble shutter valve actuator. (See VARIABLE
TUMBLE SHUTTER VALVE ACTUATOR REMOVAL/INSTALLATION [LF] .)
NOTE:
Verify that the variable tumble shutter valve actuator rod moves
using a mirror.
2008 Mazda MX-5 Miata Grand Touring
2008 ENGINE PERFORMANCE Intake Air System - MX-5 Miata