Acura TSX / Honda Accord CL. Manual — part 49

1. Before replacing the gauge control module, connect the HDS to the data link connector.

2. Select GAUGES AND INDICATORS from the HDS menu display.

3. Select "ODO REWRITE" from the ADJUSTMENTS menu display, and follow the instructions on the

menu display to retrieve the ODO value.

4. Replace the gauge control module.

5. Follow the instructions on the menu display to write the new ODO value to the new gauge control

module.

OUTSIDE AIR TEMPERATURE INDICATOR TEST

Troubleshooting

If the indicator displays "- - -" for more than two seconds after selecting the outside air temperature display
mode, Check the climate control system for DTCs (see GENERAL TROUBLESHOOTING
INFORMATION
), or an open in the LT BLU wire between the under-dash fuse/relay box and the climate
control unit.

value on the ODO/TRIP display will appear as "-", making the ODO
function unusable, and the HDS will be unable to retrieve additional ODO
values.

z

Rewriting is not possible on a gauge control module that does not
communicate.

z

Obtain a new gauge control module before starting the rewriting process.

NOTE:

To test the outside air temperature sensor (see OUTSIDE AIR TEMPERATURE
SENSOR TEST ).

2004 Acura TSX

2004 ACCESSORIES & EQUIPMENT Gauges & Indicators - TSX

Fig. 15: Indicator Displaying "- - -"

Calibration

The outside air temperature indicator's displayed temperature can be recalibrated +/-3° to meet the customer's
expectations.

1. Turn the ignition switch ON (II).

2. Press and hold the reset select button for 10 seconds. While you continue to hold the button, the display

will scroll through temperature settings from +3° to -3° as shown.

Fig. 16: Calibration Display

3. When the desired correction value appears on the display, release the button, and the recalibrated outside

2004 Acura TSX

2004 ACCESSORIES & EQUIPMENT Gauges & Indicators - TSX

air temperature will be displayed. Each time a desired correction value is entered, it replaces the previous
value.

Fig. 17: Correction Table

NOTE:

To recalibrate the display to the true temperature, remove the outside air
temperature sensor (A), but leave it connected. Submerge the sensor and a
thermometer (B) in a container of ice water (C). Select the calibration mode as
described above, then recalibrate the display to the true temperature.

2004 Acura TSX

2004 ACCESSORIES & EQUIPMENT Gauges & Indicators - TSX

Fig. 18: Submerging The Sensor & A Thermometer In A Container Of Ice Water

MAINTENANCE REQUIRED INDICATOR RESET PROCEDURE

Fig. 19: Maintenance Required Indicator Blinking Pattern Table

How to Reset

2004 Acura TSX

2004 ACCESSORIES & EQUIPMENT Gauges & Indicators - TSX

Была ли эта страница вам полезна?
Да!Нет
1 посетитель считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности