Acura TSX / Honda Accord CL. Manual — part 663
Fig. 70: Checking For Continuity Between The No. 6 Terminal Of Audio-HVAC Display
Panel Connector B (16P) & Body Ground
CONDENSER FAN CIRCUIT TROUBLESHOOTING
1. Check the No. 9 (20A) fuse in the under-hood fuse/relay box, and the No. 30 (7.5A) fuse in the under-
dash fuse/relay box.
Are the fuses OK?
YES: Go to step 2.
NO: Replace the fuse(s), and recheck.
2. Remove the condenser fan relay from the under-hood fuse/relay box, and test it (see POWER RELAY
TEST ).
Is the relay OK?
YES: Go to step 3.
NO: Replace the condenser fan relay.
3. Measure the voltage between the No. 1 terminal of the condenser fan relay 4P socket and body ground.
NOTE:
Do not use this troubleshooting procedure if the radiator fan and/or the
compressor is inoperative, refer to the symptom troubleshooting index.
2004 Acura TSX
2004 AUTOMATIC A/C SYSTEMS Climate Control System - TSX
Is there battery voltage?
YES: Go to step 4.
NO: Replace the under-hood fuse/relay box.
Fig. 71: Measuring The Voltage Between The No. 1 Terminal Of The Condenser Fan Relay
4P Socket & Body Ground
4. Connect the No. 1 and No. 2 terminals of the condenser fan relay 4P socket with a jumper wire.
Does the condenser fan run?
YES: Go to step 5.
NO: Go to step 8 .
2004 Acura TSX
2004 AUTOMATIC A/C SYSTEMS Climate Control System - TSX
Fig. 72: Connecting The No. 1 & No. 2 Terminals Of The Condenser Fan Relay 4P Socket
With A Jumper Wire
5. Disconnect the jumper wire.
6. Turn the ignition switch ON (II).
7. Measure the voltage between the No. 3 terminal of the condenser fan relay 4P socket and body ground.
Is there battery voltage?
YES: Replace the under-hood fuse/relay box.
NO: Repair open in the BLK/YEL wire between the No. 30 fuse in the under-dash fuse/relay
box and the condenser fan relay.
2004 Acura TSX
2004 AUTOMATIC A/C SYSTEMS Climate Control System - TSX
Fig. 73: Measuring The Voltage Between The No. 3 Terminal Of The Condenser Fan Relay
4P Socket & Body Ground
8. Disconnect the jumper wire.
9. Disconnect the condenser fan 2P connector.
10. Check for continuity between the No. 2 terminal of the condenser fan relay 4P socket and the No. 2
terminal of the condenser fan 2P connector.
Is there continuity?
YES: Go to step 11.
NO: Repair open in the wire between the condenser fan relay and the condenser fan.
2004 Acura TSX
2004 AUTOMATIC A/C SYSTEMS Climate Control System - TSX