Acura RSX Honda Integra. Manual — part 191
−
*03
01
11-470
EVAP System
Fuel Tank Vapor Control Valve Test (cont’d)
A
A
B
7. Connect another vacuum pump/gauge, 0
30 in.Hg,
to the fuel tank vapor signal tube (A).
8. Apply vacuum (1 pump) to the fuel tank vapor
signal tube (A), then check the vacuum on the
pump in step 6.
• If the vacuum holds, replace the fuel tank vapor
control valve (see page 11-471).
• If the vacuum is released, go to step 9.
9. Fill the fuel tank with fuel, then check for fuel in the
EVAP two way valve (A), and fuel tank vapor
recirculation hose (B).
NOTE: At either location, tiny droplets of fuel are
normal.
• If fuel runs out of the hoses at either location,
replace the fuel tank vapor control valve.
• If the fuel does not run out of the hoses at either
location, the fuel tank vapor system is OK.
10. Disconnect the fuel tank vapor vent tube from the
EVAP canister, then plug the port on the canister.
Reapply vacuum (80 pumps).
• If the vacuum holds, replace the fuel tank vapor
control valve (see page 11-471).
• If the vacuum does not hold, inspect the EVAP
canister vent shut valve O-ring. If the O-ring is OK,
replace the EVAP canister and repeat step 4.
Check for fuel running out.
Check for fuel running out.
05/06/27 17:44:55 61S6M040_110_0470
01
S6M6AZFA20323428531KBAT00
2002-2004 models
11-471
Fuel Tank Vapor Control Valve Replacement
A
B
1. Remove the fuel tank (see page 11-377).
2. Remove the fuel tank vapor control valve (A) from
the fuel tank (B).
3. Install the fuel tank vapor control valve.
4. Install the fuel tank (see page 11-377).
05/06/27 17:44:55 61S6M040_110_0471
01
S6M6AZFA20323425211KBAT00
02
*01
S6M6AZHA20323425211KBAT00
2002-2004 models
2005-2006 models
11-472
11-472
EVAP System
EVAP Canister Replacement
A
B
C
22 N·m
(2.2 kgf·m, 16 lbf·ft)
D
A
A
9.8 N·m
(1.0 kgf·m, 7.2 lbf·ft)
D
B
C
D
E
22 N·m
(2.2 kgf·m,
16 lbf·ft)
F
A
1. Remove the hoses (A) and the EVAP canister vent
shut valve 2P connector (B).
2. Remove the bolt (C).
3. Remove the EVAP canister assembly (D).
4. Install the canister in the reverse order of removal.
1. Remove the EVAP canister cover (A).
2. Remove the hoses (A), the FTP sensor 3P connector
(B), the EVAP canister vent shut valve 2P connector
(C) and the quick-connect fittings (D).
3. Remove the nuts (E).
4. Remove the EVAP canister assembly (F).
5. Install the canister in the reverse order of removal.
05/06/27 17:44:56 61S6M040_110_0472
01
02
S6M6AZFA20323428511KBAT00
03
S6M6AZHA20323428511KBAT00
2002-2004 models
2005-2006 models
11-473
11-473
FTP Sensor Replacement
22 N·m
(2.2 kgf·m, 16 lbf·ft)
A
A
A
B
C
1. Remove the EVAP canister (see page 11-472).
2. Remove the clips, hoses, connectors and bolts,
then remove FTP sensor assembly (A).
3. Remove the FTP sensor (A).
4. Install the sensor in the reverse order of removal.
1. Remove the EVAP canister (see page 11-472).
2. Remove the retaining clip (A).
3. Remove the FTP sensor (B).
4. Install the sensor in the reverse order of removal
with a new O-ring (C).