1.2 EXPLANATORY NOTES TO EMAS FAULT CODES
Fault code
Fault code description with possible cause
Symptom
600-00
Centring pressure above 175 bar due to:
-
defective accumulator
-
non-switching accumulator valve (SP071)
-
Trailing axle in centre position and does not
steer anymore
600-01
Centring pressure too low due to:
-
leak in centring circuit
-
non-switching accumulator relief valve
(SP041)
-
Trailing axle in centre position and does not
steer anymore
600-03
Internal fault in centring circuit pressure sensor
(PSY)
-
Trailing axle in centre position and does not
steer anymore
Short circuit to earth in angle sensors (F687 and
F688) on pin C3 of the ECU
Interruption or short circuit to earth in pressure
sensors (PSX and PSY) on pin D4 of the ECU
Short circuit to earth in centring circuit pressure
sensor (PSY) on pin C9 of the ECU
600-04
Internal fault in centring circuit pressure sensor
(PSY)
-
Trailing axle in centre position and does not
steer anymore
Short circuit to supply in front axle angle sensor
(F687) on pin C14 of the ECU
Short circuit to earth or to supply in angle sensors
(F687 and F688) on pin C3 of the ECU
Short circuit to supply in trailing axle angle sensor
(F688) on pin C12 of the ECU
Short circuit to earth or to supply in pressure
sensors (PSX and PSY) on pin D4 of the ECU
Interruption or short circuit to supply in centring
circuit pressure sensor (PSY) on pin C9 of the
ECU
Short circuit in centring circuit pressure sensor
(PSY) between pins C9 and D4 of the ECU
Short circuit to supply in steering circuit pressure
sensor (PSX) on pin C10 of the ECU
Interruption in pressure sensors (PSX and PSY)
on pin D3 of the ECU
600-15
Centring pressure above 100 bar due to:
-
defective accumulator
-
Trailing axle in centre position and does not
steer anymore
600-16
Centring pressure above 60 bar due to:
-
defective accumulator
-
Trailing axle in centre position and does not
steer anymore
600-17
Centring pressure too low due to:
-
leak in centring circuit