DAF 95XF. Manual — part 211
©
200438
1
Contents
ZF INTARDER EST42
DAVIE XD diagnostics manual
15
15 ZF intarder EST42
CONTENTS
Page
Date
ZF INTARDER EST42
2
©
200438
Contents
15
DAVIE XD diagnostics manual
©
200438
1-1
ZF intarder EST42 fault codes
ZF INTARDER EST42
DAVIE XD diagnostics manual
15
1. ZF INTARDER EST42 FAULT CODES
1.1 INTRODUCTION
If the electronic unit detects a system fault, this
fault is usually stored in the memory of the
electronic unit as a fault code.
Most system faults will also generate a warning.
ZF INTARDER EST42
1-2
©
200438
ZF intarder EST42 fault codes
15
DAVIE XD diagnostics manual
1.2 EXPLANATORY NOTES TO FAULT CODES FOR ZF-INTARDER EST 42
Fault code
Fault code description with possible cause
Symptom
11-11
Short circuit to earth in air supply valve (B089):
-
pin 2
-
Delayed activation of intarder
-
No noticeable system limitation
Short circuit to earth in air supply valve output:
-
pin 1 of intarder unit (D902)
Short circuit in air supply valve outputs
-
pins 1 and 34 of intarder unit (D902)
11-12
Short circuit to supply in air supply valve (B089):
-
pin 2
-
Delayed activation of intarder
-
No noticeable system limitation
Short circuit to supply in air supply valve output:
-
pin 1 of intarder unit (D902)
11-13
Interruption in air supply valve (B089):
-
pin 2
-
Delayed activation of intarder
-
No noticeable system limitation
Interruption in air supply valve output:
-
pin 1 of intarder unit (D902)
Interruption in air supply valve output:
-
pin 34 of intarder unit (D902)
13-11
Short circuit to earth in "intarder active" function
indication output:
-
pin 29 of intarder unit (D902)
-
No "intarder active" function indication on
DIP when intarder is activated
-
No noticeable system limitation
13-12
Short circuit to supply in "intarder active" function
indication output:
-
pin 29 of intarder unit (D902)
-
No "intarder active" function indication on
DIP when intarder is activated
-
No noticeable system limitation
13-13
Interruption in "intarder active" function indication
output:
-
pin 29 of intarder unit (D902)
-
No "intarder active" function indication on
DIP when intarder is activated
-
No noticeable system limitation
15-11
Short circuit to earth in brake light relay (G036)
output:
-
pin 2 of intarder unit (D902)
-
No noticeable system limitation
15-12
Short circuit to supply in brake light relay (G036)
output:
-
pin 2 of intarder unit (D902)
-
No noticeable system limitation
16-11
Short circuit to earth in "intarder warning" function
indication input:
-
pin D24 of VIC unit (D900)
-
No noticeable system limitation
Short circuit to earth in "intarder warning" function
indication output:
-
pin 52 of intarder unit (D902)
16-12
Short circuit to supply in "intarder warning"
function indication input:
-
pin D24 of VIC unit (D900)
-
Normal braking effect of the intarder if the
steering column switch is in position 1.
-
Reduced braking effect of the intarder if the
steering column switch is in position 2 or 3.
(Current through proportional valve is
restricted to 250 mA max.)
Short circuit to supply in "intarder warning"
function indication output:
-
pin 52 of intarder unit (D902)
16-13
Interruption in "intarder warning" function
indication input:
-
pin D24 of VIC unit (D900)
-
No noticeable system limitation
Interruption in "intarder warning" function
indication output:
-
pin 52 of intarder unit (D902)