DAF LF45, LF55 Series. Manual — part 32
©
2-1
System inspection with DAVIE XD
EMAS
DAVIE XD diagnostics manual
5
2. SYSTEM INSPECTION WITH DAVIE XD
2.1 GENERAL
When changes are made to the EMAS system or
when it is opened, the system must be calibrated.
2.2 "CALIBRATION" MENU
The "Calibration" menu is divided into several
tests:
-
Air test
-
Bleeding
-
Releasing the pressure
-
Hydraulic test
-
Electric test
-
Complete calibration
Air test
This test is used to check whether there is air in
the EMAS system.
If so, the EMAS system must be bled.
Bleeding
With this test, an air test will be carried out first. If
air is found in the EMAS system, the trailing axle
will be steered back and forth and there is a
possibility of releasing air. Afterwards another air
test will be carried out to check whether there is
still air in the system.
If air is still present, the above routine is repeated.
Releasing the pressure
If centring circuit components or components
connected to the centring circuit need to be
removed, the pressure in the centring circuit must
be released. When this test is selected, the
pressure in the centring circuit will be released by
opening and closing various valves.
Hydraulic test
Checking the hydraulic system:
With this test it is checked whether the various
valves are properly steered and/or the system
lines are properly connected. Furthermore, the
central position of the steering cylinder is also
calibrated.
EMAS
2-2
©
System inspection with DAVIE XD
5
DAVIE XD diagnostics manual
Electric test
Checking the electric system:
With this test it is checked whether all sensors
and valves of the EMAS system are connected;
furthermore, the resistors of the coils are
checked.
Complete calibration
The complete calibration consists of:
-
Electric test
-
Hydraulic test
-
Air test
The sensors are calibrated in between.
This complete calibration is necessary after
virtually any work is carried out on the system.
©
1
Contents
HYDRONIC 10 (ACH-EW)
DAVIE XD diagnostics manual
6
6 Hydronic 10 (ACH-EW)
CONTENTS
Page
Date
HYDRONIC 10 (ACH-EW)
2
©
Contents
6
DAVIE XD diagnostics manual
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.