DAF LF45, LF55 Series. Manual — part 59
©
1-5
ZF intarder EST42 fault codes
ZF INTARDER EST42
DAVIE XD diagnostics manual
15
46-15
No CAN communication possible between any
vehicle systems due to problems with the V-CAN:
-
interruption on pin 49 or 22 or
-
defective CAN terminating resistance
-
Normal braking effect of the intarder if the
steering column switch is in position 1.
-
Reduced braking effect of the intarder if the
steering column switch is in position 2 or 3.
(Current through proportional valve is
restricted to 250 mA max.)
-
No speed indication on DIP if V-constant
function is activated
-
No V-constant function possible
47-19
Incorrect or missing engine speed signal via
message on CAN network due to:
-
interruption on pin 22
-
short circuit to earth on pin 49
-
short circuit to supply on pin 22 and/or 49
-
defective CAN terminating resistance
-
incorrect message from UPEC unit
-
Maximum braking effect of intarder
restricted to 350 kW
-
AS Tronic gearbox does not shift down
automatically when the intarder is activated.
48-19
Incorrect or missing vehicle speed signal via
message on CAN network due to:
-
interruption on pin 22
-
short circuit to earth on pin 49
-
short circuit to supply on pin 22 and/or 49
-
defective CAN terminating resistance
-
incorrect message from MTCO unit
-
Normal braking effect of the intarder if the
steering column switch is in position 1.
-
Reduced braking effect of the intarder if the
steering column switch is in position 2 or 3.
(Current through proportional valve is
restricted to 250 mA max.)
-
No speed indication on DIP if V-constant
function is activated
-
No V-constant function possible
-
Intarder does not function during third brake
integration braking
49-19
Incorrect or missing cruise control speed signal
via message on CAN network due to:
-
interruption on pin 22
-
short circuit to earth on pin 49
-
short circuit to supply on pin 22 and/or 49
-
defective CAN terminating resistance
-
incorrect message from UPEC unit
-
V-constant function not available
51-19
Incorrect or missing current intarder braking
torque signal via message on CAN network due
to:
-
interruption on pin 22
-
short circuit to earth on pin 49
-
short circuit to supply on pin 22 and/or 49
-
defective CAN terminating resistance
-
incorrect message from UPEC unit
-
If the engine brake is switched on by foot
while the V-constant function is activated,
the intarder will not be automatically set to
the last selected current braking torque once
the engine brake is switched off.
64-19
Incorrect or missing CAN extension box signal via
message on CAN network due to:
-
interruption on pin 22
-
short circuit to earth on pin 49
-
short circuit to supply on pin 22 and/or 49
-
defective CAN terminating resistance
-
incorrect message from CAN extension box
-
No intarder braking effect possible via CAN
extension box
71-13
No supply voltage before ignition for intarder unit
(D902) due to:
-
short circuit to earth, interruption on pin 54 or
55
-
defective fuse E199
-
No noticeable system limitation
Fault code
Fault code description with possible cause
Symptom
ZF INTARDER EST42
1-6
©
ZF intarder EST42 fault codes
15
DAVIE XD diagnostics manual
72-16
Incorrect supply voltage after ignition on pin 31 or
53 of intarder unit (D902) due to:
-
overvoltage > 36 V
-
No braking effect of intarder possible in any
position of steering column switch
-
No "intarder active" function indication on
DIP when intarder is activated
-
No speed indication on DIP if V-constant
function is activated
-
No V-constant function possible
72-17
Incorrect supply voltage after ignition on pin 31 or
53 of intarder unit (D902) due to:
-
undervoltage < 16 V
-
No braking effect of intarder possible in any
position of steering column switch
-
No "intarder active" function indication on
DIP when intarder is activated
-
No speed indication on DIP if V-constant
function is activated
-
No V-constant function possible
84-15
Internal fault in intarder unit (D902)
-
No braking effect of intarder possible in any
position of steering column switch
-
No speed indication on DIP if V-constant
function is activated
-
No V-constant function possible
Fault code
Fault code description with possible cause
Symptom
©
2-1
System inspection with DAVIE XD
ZF INTARDER EST42
DAVIE XD diagnostics manual
15
2. SYSTEM INSPECTION WITH DAVIE XD
2.1 GENERAL
If the tyre size is changed or if the vehicle is
adjusted in such a way that the configuration is
changed, the electronic unit may have to be re-
programmed.
ZF INTARDER EST42
2-2
©
System inspection with DAVIE XD
15
DAVIE XD diagnostics manual
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.