DAF CF65, CF75, CF85 Series . Manual — part 61
©
2-1
Explanatory notes to ALS-S fault codes
ALS-S
DAVIE XD diagnostics manual
16
2. EXPLANATORY NOTES TO ALS-S FAULT CODES
2.1 EXPLANATORY NOTES TO ALS-S FAULT CODES
Fault code
Fault code description with possible cause
Symptom
17-19
Internal fault in VIC unit due to:
-
short circuit to supply on pin B16 of the
ALS-S unit
-
Incorrect or no actuation of hazard warning
lights
-
Alarm system cannot be activated
17-20
No signal to siren due to:
-
short circuit to earth on pin B3 of the ALS-S
unit
-
Alarm system cannot be activated
17-98
Interruption of power supply to ALS-S unit due to:
-
faulty fuse E023
-
short circuit to earth on pin A2 of the ALS-S
unit
-
Alarm system cannot be activated
-
Alarm signal after closing doors with remote
control
-
Interior detection cannot be deactivated
-
Loadspace detection cannot be deactivated
-
No read-out on LED unit
-
No alarm signal when tilting the cab
33-81
Siren backup battery discharged due to:
-
internal fault
-
No siren signal
33-97
Interruption of power supply to siren due to:
-
interruption on pin 2 (B338) of siren
-
Alarm signal when closing doors with
remote control
33-113
No siren signal due to:
-
internal fault in siren unit B388
-
No siren signal
49-65
No interior detection due to:
-
internal fault in ultrasonic unit D909
-
internal fault in ultrasonic sensor D604
(receiver)
-
internal fault in ultrasonic sensor D605
(transmitter)
-
No alarm signal by interior detection
65-49
No loadspace detection due to:
-
short circuit to earth on pin B4 of the ALS-S
unit
-
short circuit to supply on pin B4 of the ALS-S
unit
-
interruption on pin B4 of the ALS-S unit
-
No alarm signal by loadspace detection
97-49
No alarm signal from cab locking sensor due to:
-
interruption on pin B5 of the ALS-S unit
-
short circuit to supply on pin B5 of the ALS-S
unit
-
No alarm signal by cab locking sensor
99-49
No loadspace detection due to:
-
short circuit to supply on pin B6 of the ALS-S
unit
-
interruption on pin B6 of the ALS-S unit
-
No alarm signal by loadspace detection
100-49
No alarm signal by driver's side door switch:
-
short circuit to supply on pin B10 of the
ALS-S unit
-
short circuit to supply on pin B11 of the
ALS-S unit
-
No alarm signal when opening doors
-
Interruption on pin A6 of the ALS-S unit
-
Alarm signal when closing doors with
remote control
ALS-S
2-2
©
Explanatory notes to ALS-S fault codes
16
DAVIE XD diagnostics manual
100-65
No alarm signal by driver's side door switch due
to:
-
interruption on pin B16 of the ALS-S unit
-
short circuit to earth on pin B16 of the ALS-S
unit
-
Alarm system cannot be activated
-
Short circuit to supply on pin B16 of the
ALS-S unit
-
Alarm system active when the ignition is on
-
Interruption on pin A2 of the ALS-S unit
-
Alarm system cannot be activated
-
Alarm signal when closing doors with
remote control
-
Interruption on pin B10 of the ALS-S unit
-
Alarm signal when opening co-driver's door
while driver's door is open
101-49
No alarm signal by co-driver's side door switch
due to:
-
short circuit to supply on pin B11 of the
ALS-S unit
-
short circuit to supply on pin B10 of the
ALS-S unit
-
No alarm signal when opening co-driver's
side door
-
No alarm signal when opening driver's side
door
113-49
No interior detection due to:
-
short circuit to supply on pin B13 of the
ALS-S unit
-
No alarm signal by radar sensor
-
No alarm signal by ultrasonic sensors
113-50
No loadspace detection due to:
-
short circuit to supply on pin B2 of the ALS-S
unit
-
No alarm signal by loadspace detection
Fault code
Fault code description with possible cause
Symptom
©
3-1
System inspection with DAVIE XD
ALS-S
DAVIE XD diagnostics manual
16
3. SYSTEM INSPECTION WITH DAVIE XD
3.1 INSPECTION OF RADAR SENSOR
To test the radar sensor, the DAVIE XD
connection transmitter (VCI) must be hung out of
the window.
ALS-S
3-2
©
System inspection with DAVIE XD
16
DAVIE XD diagnostics manual