DAF CF65, CF75, CF85 Series . Manual — part 307
3
CF65/75/85 series
General
GEARBOX - PNEUMATIC SECTION
1-11
Regardless of any pneumatic command from
the gear lever range-change switch (5), it is now
no longer possible to switch an air pressure to
connection point 26 of the engaging cylinder (2)
and hence to shift to the low range.
Note:
The air supply to the electropneumatic valve (3)
is only available when the gear lever, and hence
also the neutral valve (1), is in the neutral
position (N).
4
ᓻ 200337
3
GEARBOX - PNEUMATIC SECTION
General
CF65/75/85 series
1-12
1.3 LOCATION OF GATE PROTECTION COMPONENTS
1.
Neutral position valve
At the side of the selector shaft housing on
the gearbox.
V300140
2.
Gate protection valve
At the left-hand or right-hand side of the
gearbox (depending on the vehicle type).
V300714
4
ᓻ 200337
3
CF65/75/85 series
General
GEARBOX - PNEUMATIC SECTION
1-13
3.
Locking cylinder
With separate air distribution block:
at the rear of the selector shaft housing.
V300002
With integrated air distribution block:
at right angles to the selector shaft housing
V300861
4.
VIC electronic unit
The electronic unit (1) is under the central
box on the co-driver’s side.
V300418
1
4
ᓻ 200337
3
GEARBOX - PNEUMATIC SECTION
General
CF65/75/85 series
1-14
5.
Low-range switch
Located at the rear of the gearbox.
V300005
4
ᓻ 200337
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.