DAF CF65, CF75, CF85 Series . Manual — part 785
11
200332
ᓻ
2-31
Changes in the electrical system from chassis number 0E570448
5
CHANGES IN THE ELECTRICAL SYSTEM
CF65/75/85 series
11
2.
AL
TERNA
TO
R/IGNITION/ST
ARTER
SWITCH/CHARGING
C
IRCUIT
CONT
ACT
CIRCUIT
If
ignition/starter
s
witch
C
539
is
turned
(contact
1
is
connected
to
p
in
6),
the
‘radio
accessories
power
supply
’
relay
(G377)
will
be
energised.
V
o
ltage
is
now
applied
to
c
ontact
1
of
relay
G377
through
fuse
E037,
wire
1
100,
contacts
1-6o
fs
w
it
c
hC
539,
wire
1
130.
When
G377
is
energised,
a
c
onnection
is
made
between
contacts
3
and
5
o
f
G
377
and
a
v
oltage
is
switched
from
the
c
onverter
to
the
radio.
ST
ARTING
C
IRCUIT
If
the
ignition
switch
C539
is
turned
(contact
1
is
connected
to
4
),
both
c
ontact
relay
G015
and
G426
will
be
activated
v
ia
wire
4001.
If
the
ignition
switch
is
turned
to
the
“start
”
position,
a
c
ontact
is
m
ade
in
this
switch
between
points
1
and
2.
The
power
is
now
supplied
from
the
batteries
through
fuse
E037,
the
c
onnection
1-2
from
the
ignition/starter
switch
and
wire
4004
on
connection
point
A3
of
the
a
larm
system.
When
the
a
larm
system
has
been
switched
of
f
using
the
remote
control,
or
by
activating
the
contact
(the
immobiliser
switches
the
a
larm
of
f
via
C
AN),
wire
4004,
connection
point
A3,
is
connected
to
w
ire
4004,
connection
point
A1.
The
c
oil
o
f
relay
G203
will
be
activated.
This
closes
connection
30
-
87.
A
v
oltage
is
now
applied
to
c
onnection
point
50
of
the
s
tarter
motor
,
through
fuse
E037,
wire
1
100,
relay
contacts
30
-
87,
wire
4002,
causing
the
starter
m
otor
to
turn.
When
the
a
larm
has
been
switched
of
f
and
the
door
has
opened,
the
s
tart
interrupter
will
be
deactivated
for
60
seconds.
If
the
engine
is
not
started
w
ithin
this
time,
the
s
tart
interrupter
is
reactivated.
If
the
a
larm
is
switched
of
f
and
the
doors
a
re
not
opened,
the
s
tart
interrupter
remains
deactivated
for
9
minutes.
If
the
vehicle
has
a
n
A
S
T
ronic
g
earbox
If
the
v
ehicle
has
an
AS
T
ronic
gearbox,
relay
G185
is
also
fitted.
When
the
c
ontact
is
switched
on
and
the
gearbox
is
in
neutral,
relay
G
185
will
be
energised.
The
v
oltage
is
now
applied
to
the
coil
of
relay
of
G203
through
wire
4004,
contacts
30
-
8
7
of
relay
G
185,
wire
4186,
contacts
3
-
4
,
w
ire
4009.
This
relay
is
energised.
A
v
oltage
is
now
applied
to
c
onnection
point
50
of
the
starter
m
otor
,
through
E037,
wire
1
100,
contacts
30
-
8
7
and
wire
4002,
causing
the
starter
m
otor
to
turn.
As
soon
as
the
m
otor
turns,
the
V
IC
applies
a
voltage
to
connection
point
C42.
The
v
oltage
is
then
applied
to
c
onnection
point
1
o
f
relay
G372
via
w
ire
3157.
This
relay
is
energised,
breaking
the
starting
circuit.
Note:
When
the
immobiliser
applies
a
voltage
to
wire
4009,
the
c
ab
heater
is
also
switched
of
f
if
the
v
ehicle
m
ust
m
eet
requirements
for
the
transportation
of
hazardous
substances.
CHARGING
C
IRCUIT
If
the
c
ontact
is
a
ctivated,
there
is
v
oltage
on
connection
point
85
of
relay
G
426.
This
relay
is
activated.
V
o
ltage
is
now
applied
to
connection
point
15
of
the
a
lternator
through
fuse
E037,
contacts
30
-
8
7
o
f
relay
G426,
fuse
E350
and
wire
1380.
An
internal
resistor
in
the
a
lternator
is
energised
b
y
a
n
IC
in
the
carbon
brush
holder
.
This
resistor
ensures
that
a
low
level
o
f
current
passes
through
the
energising
resistor
.
This
excites
a
magnetic
field
in
the
alternator
.
After
s
tarting,
the
v
oltage
on
terminals
B
+
and
15
will
rise
to
about
28.5
V
.
O
nce
this
v
oltage
is
reached,
the
IC
in
the
regulator
interrupts
the
pre-exciter
c
oil
to
enable
the
voltage
to
be
regulated.
The
m
agnetic
field
w
ill
now
disappear
,
s
o
that
the
generator
will
not
be
energised
for
a
s
hort
period
o
f
time.
As
a
result,
the
v
oltage
on
outputs
B
+
and
15
will
drop.
200332
ᓻ
2-32
5
CHANGES IN THE ELECTRICAL SYSTEM
Changes in the electrical system from chassis number 0E570448
CF65/75/85 series
11
The
regulator
reactivates
w
hen
the
v
oltage
drops
below
27.6V
.
T
his
m
eans
that
the
voltage
supplied
b
y
the
generator
remains
relatively
constant.
T
he
batteries
are
s
upplied
through
the
B
+
generator
output.
The
a
lternator
charging
current
warning
lamp
is
activated
v
ia
wire
1020,
which
is
c
onnected
to
the
V
IC
(D900).
T
he
VIC
c
ontrols
the
D
IP
via
the
CAN
network.
T
he
voltage
on
wire
1020
is
switched
by
the
c
ontrol
IC.
The
a
lternator
is
also
equipped
with
a
‘sens
’line.
This
connection
continuously
measures
the
v
oltage
on
connection
point
30
of
the
s
tarter
motor
.
If
the
v
oltage
on
connection
point
30
drops,
the
voltage
is
immediately
c
orrected
by
the
c
ontrol
IC.
The
alternator
will
increase
the
voltage
until
a
value
o
f
28.5V
is
reached
again.
V
ARIANTS
Location
42
If
no
alarm
system
is
fitted,
wires
4004
and
4004A
are
c
onnected
through
in
connector
603.
200332
ᓻ
2-33
Changes in the electrical system from chassis number 0E570448
5
CHANGES IN THE ELECTRICAL SYSTEM
CF65/75/85 series
11
2
1358030/16-24
EL001055
123456789
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
3
8
3
9
4
0
4
1
4
2
4
3
4
4
4
5
4
6
4
7
4
8
4
9
5
0
5
1
5
2
5
3
1008
1010
1000
1008
1008
3084
4002
4001
4004
1020
1020
1130
1100
1100
1100
1100
1008
1000
4002
1008
1008
3084
1380
1000
1000
1000
1380
1108
1130
1234
1234
4004
1380
1380
3157
4009
3157
1020
3157
1100
4002
4009
4004
4690
1010
4186
1363
1211
4690
4690
4004
4004
4001
4001
4001
9050
9050
9050
9050
9050
A500
G014
1
5
50
B010
M
31
30
G
3
B
B+
L /2
15 /3
S /4
A513
10
575
20
575
8
390
1/416
1/417
6/403
7/403
10/403
8/403
15/402
3/403
19/403
21/403
14/400
16/400
15/400
4/403
G525
E286
125A
2
1
E279
5A
12
C539
1/222
2/222
4/222
6/222
12/403
87
86
85
87A
30
G185
A3/
603
A1/
603
D911
C42/
594
D900
D29/
595
14
574
1
577
7
575
B365
A7
36
D895
A4
36
1/403
16/401
12/400
!
!
!
2
869
6
390
16
574
E599
2
1
30
87
86
85
G015
DVB
87
30
86
85
G203
D929
1010
1000
E037
15A
1000
1010
4001
1100
1234
E350
10A
30
86
85
87A
8
7
G426
3
2
1
45
G377
1130
1108
3
2
1
45
G372
E035
10A
4186
3157
200332
ᓻ
2-34
5
CHANGES IN THE ELECTRICAL SYSTEM
Changes in the electrical system from chassis number 0E570448
CF65/75/85 series
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.