DAF CF65, CF75, CF85 Series . Manual — part 546
10
A
V
OL
TA
GE
BEFORE
AND
AFTER
C
ONT
ACT
VOL
TA
GE
BEFORE
CONT
ACT
A
constant
voltage
is
supplied
to
pin
1
of
connector
416
through
wire
1008,
point
30
on
the
starter
motor
,fuse
E286,
the
+
bolt
in
the
dashboard
connector
lead-through
and
the
voltage
distribution
block.
Power
is
also
supplied
(via
w
ire
1008)
from
point
30
of
the
starter
motor
to
the
B+
connection
of
the
alternator
and
to
relay
G
014
(glow-plug
relay).
Power
is
supplied
to
the
“S”
(sens)
connection
of
the
alternator
from
point
30
of
the
starter
motor
via
fuse
E279
and
wire
3084.
Only
wire
1008
to
the
+
bolt
in
the
dashboard
connector
lead-through
is
fuse-protected
by
fuse
E286
(125A).
The
other
wires
are
NOT
fuse-protected
and
they
can
only
be
m
ade
dead
by
disconnecting
the
battery
leads..
VOL
TA
GE
AFTER
C
ONT
ACT
A
voltage
is
supplied
to
contact
relay
G015
(connection
point
30)
via
the
starter
m
otor
(connection
point
30).
T
his
connection
point
may
be
connected
to
w
ire
1010
over
contact
relay
G
015.
This
wire
is
only
fuse-protected
w
ith
fuse
E286
(125A).
OPERA
T
ION
When
the
accessories/ignition/starter
switch
(C539)
is
set
to
the
“accessories”
position
(connection
between
points
1
and
6),
a
voltage
is
supplied
to
connection
point
1
of
relay
G
377
via
w
ire
1000,
fuse
E037,
accessories/ignition/starter
switch
(C539)
(contact
points
1
-
6)
and
wire
1130.
When
the
accessories/ignition/starter
switch
(C539)
is
set
to
the
“contact”
position
(connection
between
points
1
and
4),
relay
G015
is
energised
via
wire
1000,
fuse
E037,
accessories/ignition/starter
switch
(C539)
(contact
points
1
-
4)
and
wire
4001,
relay
G015. This
then
connects
wire
1000
(voltage
before
contact)
to
wire
1010
(voltage
after
contact).
At
the
same
m
oment
this
voltage
is
also
applied
to
connection
point
85
of
relay
G
426.
This
relay
is
also
activated
and
connects
contacts
30
and
87.
A
voltage
is
now
applied
both
to
fuse
E
350
and
to
fuse
E351
via
fuse
E037,
contacts
30
-
87
and
wire
1234.
The
voltage
goes
to
connection
point
15
of
the
alternator
via
fuse
E
350.
When
the
accessories/ignition/starter
switch
(C539)
is
turned
against
the
pressure
of
the
spring
(connection
between
points
1
and
2),
relay
G
015
and
relay
G
426
remain
energised
and
a
volt
age
is
supplied
to
the
alarm
syst
em
(D91
1)
(if
present)
or
directly
to
connector
403,
connection
point
2,
via
w
ire
1000,
fuse
E037,
accessories/ignition/starter
switch
(C539),
contacts
1
-
2
and
wire
4004.
When
the
ignition/starter
key
is
released,
the
ignition/starter
switch
automatically
springs
back
and
remains
in
the
“contact”
position.
200404
2-24
5
ELECTRICAL SYSTEM
Electrical system
CF65/75/85 series ≥0E621376
10
A
1358030/26
EL001292
123456789
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
3
8
3
9
4
0
4
1
4
2
4
3
4
4
4
5
4
6
4
7
4
8
4
9
5
0
5
1
5
2
5
3
1008
1010
4001
4001
4001
9050
1000
1008
1008
3084
1100
1100
1100
1020
1008
1000
4002
4002
1008
1008
3084
1380
1000
1000
1380
1234
1234
9050
9999
9050
9050
1380
4004
1130
4001
1380
1010
1000
1020
1234
1381
A500
G014
1
5
G377
1
36
D911
A3
46
G203
87
2
30
87
86
85
G015
50
B010
M
31
30
G
3
B
B+
L /2
15 /3
S /4
A513
1
913
20
913
DVB
1/416
1/417
6/403
7/403
10/403
8/403
15/402
4/403
G525
G525
E286
125A
2
1
E279
5A
12
C539
1/222
2/222
4/222
6/222
12/403
20
914
D29/
595
D900
G516
D929
1010
1000
E037
15A
1000
1010
4001
1100
1234
E350
10A
30
86
85
87A
87
G426
8/401
25/400
1234
E351
10A
200404
2-25
Electrical system
5
ELECTRICAL SYSTEM
CF65/75/85 series ≥0E621376
10
B
O
VER
VIEW
OF
EARTHING
POINTS
This
section
diagram
gives
an
overview
of
all
the
earth
connections,
w
ith
w
ire
m
arkings
and
connector
points.
VARIANTS
Location 10
connector
580:
superstructure
connection,
accessories
18
connector
482:
cab
heater
ACH-H
connector
582:
cab
heater
ACH-E
59
connector
644:
only
for
AGC
67
connector
869:
only
for
AS
Tr
onic
69
connector
403:
only
for
AS
Tr
onic
71
connector
868:
only
for
AS
Tr
onic
76
connector
860:
loop-through
to
ECAS
200404
2-26
5
ELECTRICAL SYSTEM
Electrical system
CF65/75/85 series ≥0E621376
10
B
1358030/26
EL001293
1
23456789
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
3
8
3
9
4
0
4
1
4
2
4
3
4
4
4
5
4
6
4
7
4
8
4
9
5
0
5
1
5
2
5
3
M50
M50
M60
M18
M17
M75
M72
M87
M88
M86
M73
M76
M77
M81
M85
M85
M83
M52
M51
M63
M55
M41
M54
M59
M61
M71
M53
M62
M70
M96
M84
M74
M1
M1
M1
M4
M4
M2
M3
M3
M2
M5
M7
M1
M8
M9
M6
M3
M4
M2
M6
M5
M4
M3
M2
M13
M12
M11
M20
M21
M11
M6
M5
M1
M1
M1
M4
M3
M7
M8
M6
M5
M2
M5
M4
M2
M1
M3
M2
M3
M6
M1
M82
M105
M5
M25
M10
M11
M11
M10
M17
M14
M18
M1
M7
M8
M9
M1
M1
M1
M95
M6
M5
M4
M3
M2
M4
M6
M2
M101
M1
M2
M1
M3
M1
M3
M4
M5
M2
M2
M1
M3
M4
M1
M2
M1
M1
M3
M2
M5
M7
M8
M4
M3
M3
M2
M102
M111
M112
M114
M110
M113
M100
M100
M107
M4
M2
M106
M3
M6
M2
M1
M5
M2
M8
M7
M1
M3
M4
M1
M2
M3
M5
M4
M5
M1
M1
M2
M3
M16
M1
!
!
9
560
10
582
21
572
6
602
12
288
B000
3
C063
2
D912
2
C751
B
B001
2
C007
2
B042
2
C001
2
C003
2
B130
1
C015
2
B028
2
12
397
C736
B
C736
7
C837
B
C837
6
C837
4
C832 A10
A076
3
B030
31
C840
6
C750
B
A007
2
C696
4
B032
2
E511
2
B365
8
F656
2
D895
A3
B015
8
D895
A1
F619
4
C760
1
C802
1
C739
B
C740
B
C741
B
C742
B
C749
B
C748
B
570
21
911
3
626
1
491
4
564
9
646
2
571
9
B017
2
B199
4
E575
6
F628
B2
F628
A2
12
284
18
559
6
565
21
568
B129
1
C014
2
C000
2
C002
2
C006
2
F048
2
C062
2
9
556
1
640
1
619
C067
2
C016
2
C695
2
C010
2
20
554
B175
4
C129
2
C191
2
C011
2
C858
10
C115
2
B026
2
D905
8
G516
D911
A7
D910
4
6
601
8
546
F616
4
F120
2
E592
2
E594
2
F118
2
B293
2
B246
2
B245
2
B079
2
C835
B
C836
B
C727
B
C725
B
C764
3
C764
B
C763
B
21
554
C716
10
C145
2
12
597
12
623
3
606
C144
2
C813
10
G299
86
C162
2
C164
2
C166
2
C168
2
F047
2
9
573
1
618
B358
2
B033
2
C017
2
9
883
D969
3
5
580
6
580
18
574
C774
B
C765
B
C853
B
C735
B
C072
2
C774
3
C778
B
C778
4
C737
B
C737
1
200404
2-27
Electrical system
5
ELECTRICAL SYSTEM
CF65/75/85 series ≥0E621376
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст