DAF CF65, CF75, CF85 Series . Manual — part 1123
©
200518
3-1
Inspection and adjustment
EXPLANATORY NOTES ON THE MAINTENANCE ACTIVITIES
ΧΦ65/65 (II) series
5
3. INSPECTION AND ADJUSTMENT
3.1 CHECKING PEDAL RUBBERS
1.
Check that the pedal rubbers are still
securely mounted on the pedal.
2.
Check that the pedal rubbers are not worn
out and there is still sufficient tread.
EXPLANATORY NOTES ON THE MAINTENANCE ACTIVITIES
3-2
©
200518
Inspection and adjustment
5
ΧΦ65/65 (II) series
3.2 CHECKING THE BATTERY FLUID LEVEL
Avoid sparks and open flames in the
vicinity of batteries.
Battery acid is an aggressive fluid.
In the event of contact with the skin:
rinse the skin with plenty of water for
a sustained period. If redness or
pain persists, consult a doctor.
Remove any clothing affected and
rinse with water.
In the event of contact with the eyes:
rinse with plenty of water for at least
15 minutes and consult a doctor.
If swallowed: do NOT induce
vomiting. Rinse the mouth, drink two
glasses of water and consult a
doctor.
In the event of inhalation: get fresh
air, rest and consult a doctor.
1.
Check the electrolyte level. The electrolyte
level must be approx. 10 mm above the
plates or up to the level indicator if available.
2.
If necessary, top up the batteries, see
chapter "Draining and filling".
3.3 CHECKING THE BATTERY TERMINALS
1.
Visually check the battery terminals for
corrosion. Clean the battery terminals if
necessary, see chapter on "Cleaning".
2.
Check the attachment of the battery
terminals.
}
G000380-2
CF65
CF65 (II)
©
200518
3-3
Inspection and adjustment
EXPLANATORY NOTES ON THE MAINTENANCE ACTIVITIES
ΧΦ65/65 (II) series
5
3.4 CHECKING THE FLUID LEVEL OF THE CAB TILTING PUMP
1.
The fluid level must be checked when the
cab is in the driving position.
2.
The cock (2) should be in the "tilting back"
position (anti-clockwise).
3.
Unscrew the filler plug (1) 3 to 4 turns. Wait
until the overpressure, if any, has left the
reservoir. Remove filler plug (1).
4.
Start pumping (maximum 5 pump strokes).
Ensure that the pump lever is in the lowest
position.
5.
Check the fluid level. This level should be no
more than 2 cm below the top of the filling
opening. Top up if necessary.
6.
Fit the filler plug (1) and hand tighten it.
3.5 CHECK CAB FASTENING
1.
Check that all attachment bolts are in place.
2.
Visually inspect the attachment of the cab to
the tilting mechanism.
3.
Visually inspect the seals and condition of
the tilting mechanism.
Engine, cooling system and fuel system
M201062
N
!
1
2
K1 01 660
EXPLANATORY NOTES ON THE MAINTENANCE ACTIVITIES
3-4
©
200518
Inspection and adjustment
5
ΧΦ65/65 (II) series
3.6 BLEEDING THE FUEL SYSTEM
When venting the fuel system, a
quantity of fuel will escape. Collect
the fuel and avoid the risk of fire.
Stop pumping as soon as a
resistance is felt. If you continue
pumping, the fuel system may
become internally damaged.
Note:
When the hand pump is used, the fuel system will
be automatically bled. Air will be fed back to the
tank through the return pipe.
Racor fuel prefilter/water separator
1.
Open the vent plug (2) a couple of turns.
2.
Pump the primer pump (1) until fuel comes
out of the vent plug (2).
3.
Close the vent plug (2).
4.
Use the primer pump until a clearly higher
resistance is felt.
}
}
1
2
3
4
5
7
6
8
i400356