DAF CF65, CF75, CF85 Series . Manual — part 732
A
P
OWER
BEFORE
AND
AFTER
IGNITION
POWER
B
EFORE
IGNITION
A
c
onstant
voltage
is
supplied
to
p
in
1
o
f
connector
416
through
wire
1000,
point
30
on
the
s
tarter
motor
,
fuse
E286,
the
+
bolt
in
the
dashboard
c
onnector
lead-through
and
the
voltage
distributor
block.
Power
is
a
lso
s
upplied
(via
w
ire
1000)
from
point
30
on
the
s
tarter
motor
to
the
B+
connection
of
the
a
lternator
and
to
relay
G
014
(glow
p
lug
relay).
Only
wire
1000
to
the
+
bolt
in
the
dashboard
connector
lead-through
is
fuse-protected
by
a
125
A
fuse.
The
o
ther
wires
a
re
NOT
fuse-protected
and
they
can
only
b
e
m
ade
dead
by
disconnecting
the
battery
leads.
There
is
a
voltage
on
the
“S”(sens)-connection
of
the
a
lternator
from
point
30
of
the
s
tarter
motor
v
ia
fuse
E279
and
wire
3084.
POWER
A
FTER
IGNITION
Power
is
s
upplied
to
c
ontact
relay
G015
(point
30)
via
the
starter
m
otor
(connection
point
30).
This
connection
point
may
b
e
c
onnected
to
wire
1010
over
contact
relay
G015.
This
wire
is
NOT
fuse-protected.
OPERA
T
ION
When
the
ignition/starter
switch
(C539)
is
set
to
the
“accessories”
position
(connection
between
points
1
and
6),
power
is
supplied
to
relay
G
178
via
w
ire
1000,
fuse
E037,
ignition/starter
s
witch
(C539)
(contact
points
1
-
3
)
and
wire
1
130.
When
the
ignition/starter
switch
(C539)
is
set
to
the
“contact”
position
(connection
between
points
1
and
4),
relay
G015
is
energised
v
ia
wire
1000,
fuse
E037,
ignition/starter
s
witch
(C539)
(contact
points
1
-
4
)
and
wire
4001.
This
then
connects
wire
1000
(power
before
ignition)
to
wire
1010
(power
after
ignition).
When
the
ignition/starter
switch
(C539)
is
turned
against
the
pressure
of
the
s
pring
(connection
between
points
1
and
2),
relay
G015
remains
energised
and
power
is
supplied
to
the
alarm
system
(D91
1)
(if
present)
o
r
d
irectly
to
c
onnector
403
connection
point
2
v
ia
wire
1000,
fuse
E037,
ignition/starter
s
witch
(C539)
(contact
points
1
-
2
)
and
wire
4004.
The
c
oil
o
f
relay
G372
is
energised
v
ia
the
c
entral
PCB.
When
the
ignition/starter
k
ey
is
released,
the
ignition/starter
s
witch
automatically
springs
back
and
remains
in
the
“contact”
position.
0202
ᓻ
2-24
5
ELECTRICAL SYSTEM
Electrical system
series
65/75/85
CF
A
1358030/15
EL000483
1
23456789
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
3
8
3
9
4
0
4
1
4
2
4
3
4
4
4
5
4
6
4
7
4
8
4
9
5
0
5
1
5
2
5
3
1000
1010
1000
1000
1000
1100
1100
3084
1234
1100
1100
1020
1000
1000
4002
4002
1000
1000
3084
1234
1234
1000
1000
1234
1234
1130
1234
1010
4001
4001
4004
1000
1020
A500
G014
1
5
G178
30
2
G203
30
2
G178
85
2
D911
A3
46
G203
87
2
30
87
86
85
G015
50
B010
M
31
30
G
3
B
B+
L
15
S
A513
10
575
20
575
DVB
1/416
1/417
23/400
15/402
G525
G525
E286
125A
2
1
E279
5A
12
C539
1/222
2/222
4/222
6/222
D929
1010
1000
E037
15A
1000
1010
E143
10A
7
575
29/
595
D900
G516
0202
ᓻ
2-25
5
ELECTRICAL SYSTEM
Electrical system
series
65/75/85
CF
B
O
VER
VIEW
OF
EARTH
C
ONNECTIONS
This
section
d
iagram
gives
a
n
o
verview
o
f
a
ll
the
earth
connections,
w
ith
w
ire
m
arkings
and
connector
points.
V
ARIANTS
Location
9
=
1
=
accessories
superstructure
connection
61
=
2
=
for
ABS/ASR-D
(D850)
connector
585,
pin
21.
for
EBS
(D880)
connector
584,
pin
2
1
59
=
3
=
4
0
A
accessories
connector
.
0202
ᓻ
2-26
5
ELECTRICAL SYSTEM
Electrical system
series
65/75/85
CF
B
1358030/15
EL000484
1
23456789
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
3
8
3
9
4
0
4
1
4
2
4
3
4
4
4
5
4
6
4
7
4
8
4
9
5
0
5
1
5
2
5
3
M100
M100
M107
M102
M106
M101
M105
M50
M50
M60
M75
M74
M72
M87
M85
M88
M73
M76
M77
M81
M90
M83
M52
M51
M63
M54
M55
M18
M17
M59
M61
M71
M53
M62
M70
M84
M86
M1
M1
M5
M1
M1
M4
M4
M2
M3
M3
M2
M3
M5
M7
M1
M8
M9
M6
M3
M2
M6
M2
M1
M3
M4
M2
M3
M2
M5
M3
M4
M2
M6
M5
M4
M1
M1
M1
M3
M2
M13
M12
M11
M13
M20
M21
M12
M11
M2
M6
M5
M1
M1
M1
M4
M6
M5
M1
M3
M5
M4
M1
M2
M2
M1
M6
M3
M82
M96
M25
M11
M10
M17
M14
M18
M1
M4
M5
M1
M1
M3
M95
M1
M1
M6
M2
M1
M3
M4
M1
M5
M3
M2
M6
M5
M4
M3
M2
M4
M5
M6
M7
M8
M9
M1
M2
M2
M4
M2
M3
M5
M4
M2
M3
M4
M1
M1
M1
M3
M2
M3
M4
M5
M3
M2
M2
M3
M2
!
21
568
18
558
21
554
9
573
6
602
21
572
1
618
12
288
B358
2
B033
2
C716
10
C010
2
B000
3
C063
2
D912
2
C144
2
B001
2
C017
2
C007
2
B042
2
C001
2
C003
2
B130
1
C015
2
C727
B
C725
B
C764
3
C764
B
C763
B
B017
2
B199
4
C695
2
C696
4
B028
2
9
571
12
284
9
560
18
559
20
554
12
597
12
623
3
606
9
556
1
619
12
397
C736
B
C774
B
C765
B
C853
B
C735
B
C072
2
C778
B
C736
7
C837
B
C837
6
C837
4
C832 A10
A076
3
B030
31
C840
6
C751
B
C750
B
A007
2
E511
2
B365
8
F656
6
D895
A3
B015
8
D895
A1
C774
3
F619
4
C778
4
C760
1
C802
1
C899
2
C739
B
C740
B
C741
B
C742
B
C749
B
C737
B
C737
1
C748
B
580
5
570
21
670
3
574
18
564
6
640
1
580
6
E575
6
C067
2
C016
2
F628
B2
F628
A2
C014
2
B129
1
C000
2
B175
4
C129
2
C191
2
C002
2
C006
2
C011
2
C145
2
C858
10
C115
2
B026
2
D905
8
F047
2
F048
2
C062
2
B032
2
C813
10
G299
86
C162
2
C164
2
C166
2
C168
2
1
G516
D911
A7
D910
4
1
626
6
601
12
637
4
491
F616
4
E569
2
B293
2
B079
2
B246
2
B245
2
B245
2
C835
B
C836
B
0202
ᓻ
2-27
5
ELECTRICAL SYSTEM
Electrical system
series
65/75/85
CF
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст