Honda Element. Manual — part 586

Fig. 109: Inspection Data Chart
Courtesy of AMERICAN HONDA MOTOR CO., INC.

PRESSURE TEST

PRESSURE TEST REFERENCE

Test results

Related symptoms

Probable cause

Remedy

Discharge
(high) pressure
abnormally high

After stopping A/C
compressor, pressure drops
about 196 kPa (2.0 kgf/cm

2

,

28 psi) quickly, and then falls
gradually.

Air in system

Recover, evacuate (see SYSTEM
EVACUATION
), and recharge
with specified amount (see
SYSTEM CHARGING ).

Reduced or no airflow

Clogged A/C
condenser or
radiator fins

Clean.

2007 Honda Element EX

2007-2008 HVAC HVAC - Element

through A/C condenser.

A/C condenser
or radiator fan
not working
properly

Check voltage and fan rpm.

Check fan direction.

Line to A/C condenser is
excessively hot.

Restricted flow of
refrigerant in system

Restricted lines.

Discharge
pressure
abnormally low

High and low-pressures are
balanced soon after stopping
A/C compressor. Low side is
higher than normal.

Faulty A/C
compressor
discharge valve

Faulty A/C
compressor seal

Replace the A/C compressor.

Outlet of expansion valve is
not frosted, low-pressure
gauge indicates vacuum.

Faulty expansion
valve

Moisture in
system

Replace.

Recover, evacuate, and
recharge with specified
amount.

Suction (low)
pressure
abnormally low

Expansion valve is not
frosted, and low-pressure line
is not cold. Low-pressure
gauge indicates vacuum.

Frozen
expansion valve
(Moisture in
system)

Faulty expansion
valve

Recover, evacuate, and
recharge with specified
amount.

Replace the expansion
valve.

Discharge temperature is low,
and the airflow from vents is
restricted.

Frozen evaporator

Run the fan with A/C compressor
off, then check evaporator
temperature sensor.

Expansion valve is frosted.

Clogged expansion
valve

Clean or replace.

Suction pressure
abnormally high

Low-pressure hose and check
joint are cooler than the
temperature around
evaporator.

Expansion valve open
too long

Repair or replace.

Suction pressure is lowered
when A/C condenser is
cooled by water.

Excessive refrigerant
in system

Recover, evacuate, and recharge
with specified amount.

High and low-pressures are
equalized as soon as the A/C
compressor is stopped, and
both gauges fluctuate while
running.

Faulty gasket

Faulty high-
pressure valve

Foreign particle
stuck in high-
pressure valve

Replace the A/C compressor.

Suction and
discharge

Reduced airflow through A/C

Clogged A/C
condenser or
radiator fins

Clean.

2007 Honda Element EX

2007-2008 HVAC HVAC - Element

pressures
abnormally high

condenser.

A/C condenser
or radiator fan
not working
properly

Check voltage and fan rpm.

Check fan direction.

Suction and
discharge
pressures
abnormally low

Low-pressure hose and metal
end areas are cooler than
evaporator.

Clogged or kinked
low-pressure hose
parts

Repair or replace.

Temperature around
expansion valve is too low
compared with that around
receiver/dryer.

Clogged high-pressure
line

Repair or replace.

Refrigerant
leaks

A/C compressor clutch is
dirty.

A/C compressor shaft
seal leaking

Replace the A/C compressor.

A/C compressor bolt(s) are
dirty.

Leaking around bolt(s)

Tighten bolt(s) or replace the A/C
compressor.

A/C compressor gasket is wet
with oil.

Gasket leaking

Replace the A/C compressor.

A/C fitting is dirty.

Leaking O-ring

Clean A/C fitting and replace O-
ring.

2007 Honda Element EX

2007-2008 HVAC HVAC - Element

2007-08 ENGINE PERFORMANCE

Idle Control System - Element

COMPONENT LOCATION INDEX

Fig. 1: Identifying Idle Control System Component Location
Courtesy of AMERICAN HONDA MOTOR CO., INC.

DTC TROUBLESHOOTING

2007 Honda Element EX

2007-08 ENGINE PERFORMANCE Idle Control System - Element

2007 Honda Element EX

2007-08 ENGINE PERFORMANCE Idle Control System - Element

Была ли эта страница вам полезна?
Да!Нет
3 посетителя считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности