Honda Element. Manual — part 586
Fig. 109: Inspection Data Chart
Courtesy of AMERICAN HONDA MOTOR CO., INC.
PRESSURE TEST
PRESSURE TEST REFERENCE
Test results
Related symptoms
Probable cause
Remedy
Discharge
(high) pressure
abnormally high
After stopping A/C
compressor, pressure drops
about 196 kPa (2.0 kgf/cm
2
,
28 psi) quickly, and then falls
gradually.
Air in system
Recover, evacuate (see SYSTEM
EVACUATION ), and recharge
with specified amount (see
SYSTEM CHARGING ).
Reduced or no airflow
Clogged A/C
condenser or
radiator fins
Clean.
2007 Honda Element EX
2007-2008 HVAC HVAC - Element
through A/C condenser.
A/C condenser
or radiator fan
not working
properly
Check voltage and fan rpm.
Check fan direction.
Line to A/C condenser is
excessively hot.
Restricted flow of
refrigerant in system
Restricted lines.
Discharge
pressure
abnormally low
High and low-pressures are
balanced soon after stopping
A/C compressor. Low side is
higher than normal.
Faulty A/C
compressor
discharge valve
Faulty A/C
compressor seal
Replace the A/C compressor.
Outlet of expansion valve is
not frosted, low-pressure
gauge indicates vacuum.
Faulty expansion
valve
Moisture in
system
Replace.
Recover, evacuate, and
recharge with specified
amount.
Suction (low)
pressure
abnormally low
Expansion valve is not
frosted, and low-pressure line
is not cold. Low-pressure
gauge indicates vacuum.
Frozen
expansion valve
(Moisture in
system)
Faulty expansion
valve
Recover, evacuate, and
recharge with specified
amount.
Replace the expansion
valve.
Discharge temperature is low,
and the airflow from vents is
restricted.
Frozen evaporator
Run the fan with A/C compressor
off, then check evaporator
temperature sensor.
Expansion valve is frosted.
Clogged expansion
valve
Clean or replace.
Suction pressure
abnormally high
Low-pressure hose and check
joint are cooler than the
temperature around
evaporator.
Expansion valve open
too long
Repair or replace.
Suction pressure is lowered
when A/C condenser is
cooled by water.
Excessive refrigerant
in system
Recover, evacuate, and recharge
with specified amount.
High and low-pressures are
equalized as soon as the A/C
compressor is stopped, and
both gauges fluctuate while
running.
Faulty gasket
Faulty high-
pressure valve
Foreign particle
stuck in high-
pressure valve
Replace the A/C compressor.
Suction and
discharge
Reduced airflow through A/C
Clogged A/C
condenser or
radiator fins
Clean.
2007 Honda Element EX
2007-2008 HVAC HVAC - Element
pressures
abnormally high
condenser.
A/C condenser
or radiator fan
not working
properly
Check voltage and fan rpm.
Check fan direction.
Suction and
discharge
pressures
abnormally low
Low-pressure hose and metal
end areas are cooler than
evaporator.
Clogged or kinked
low-pressure hose
parts
Repair or replace.
Temperature around
expansion valve is too low
compared with that around
receiver/dryer.
Clogged high-pressure
line
Repair or replace.
Refrigerant
leaks
A/C compressor clutch is
dirty.
A/C compressor shaft
seal leaking
Replace the A/C compressor.
A/C compressor bolt(s) are
dirty.
Leaking around bolt(s)
Tighten bolt(s) or replace the A/C
compressor.
A/C compressor gasket is wet
with oil.
Gasket leaking
Replace the A/C compressor.
A/C fitting is dirty.
Leaking O-ring
Clean A/C fitting and replace O-
ring.
2007 Honda Element EX
2007-2008 HVAC HVAC - Element
2007-08 ENGINE PERFORMANCE
Idle Control System - Element
COMPONENT LOCATION INDEX
Fig. 1: Identifying Idle Control System Component Location
Courtesy of AMERICAN HONDA MOTOR CO., INC.
DTC TROUBLESHOOTING
2007 Honda Element EX
2007-08 ENGINE PERFORMANCE Idle Control System - Element
2007 Honda Element EX
2007-08 ENGINE PERFORMANCE Idle Control System - Element