Honda Element. Manual — part 567
run the self-diagnostic function, do the following:
1. Turn the ignition switch OFF.
2. Press the recirculation control switch and the rear window defogger switch.
3. While holding the both switches down, turn the ignition switch ON (II).
4. The self-diagnosis will begin, and run for about 15 seconds.
If there is any problem in the system after self-diagnosis is finished, the recirculation indicator will
blink the Diagnostic Trouble Code (DTC) 7 through 15.
If no DTCs are found, the indicator will not blink.
Fig. 7: Identifying HVAC Control Panel Indicator
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Example of DTC indication Pattern (DTC 7)
Fig. 8: DTC Indication Pattern
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Resetting the self-diagnostic Function
Turn the ignition switch OFF to cancel the self-diagnostic function. After completing repair work, run the self-
diagnostic function again to make sure that there are no other malfunctions.
Max Cool Position Function
When the mode control dial is in the MAX A/C position, the heater control panel will automatically select the
Recirculation mode and turn the A/C on. The recirculation switch and A/C switch are disabled and cannot be
2007 Honda Element EX
2007-2008 HVAC HVAC - Element
turned off in this mode. If the control panel fails to function as described, replace it.
DTC TROUBLESHOOTING INDEX
DTC TROUBLESHOOTING INDEX
In case of multiple problems, the recirculation indicator will indicate only the DTC with the least number of
blinks.
SYMPTOM TROUBLESHOOTING INDEX
SYMPTOM TROUBLESHOOTING INDEX
DTC (Recirculation Indicator Blinks)
Detection Item
7
An open in the air mix control motor circuit
8
A short in the air mix control motor circuit
9
A problem in the air mix control linkage, door, or
motor
10
A short or open in the mode control motor circuit
11
A problem in the mode control linkage, doors, or
motor
12
A problem in the blower motor circuit
13
A problem in the EEPROM in the heater control
panel; the control panel must be replaced
14
An open in the evaporator temperature sensor
circuit
15
A short in the evaporator temperature sensor circuit
Symptom
Diagnostic procedure
Also check for
Recirculation control
doors do not change
between Fresh and
Recirculate
Recirculation control motor circuit
troubleshooting (see RECIRCULATION
CONTROL MOTOR CIRCUIT
TROUBLESHOOTING )
Blown fuse No. 14 (10 A)
in the under-dash
fuse/relay box
Cleanliness and tightness
of all connectors
Blower, heater controls,
and A/C do not work
Heater control power and ground circuit
troubleshooting (see HEATER CONTROL
POWER AND GROUND CIRCUIT
TROUBLESHOOTING )
Blown fuse No. 14(10 A)
in the under-dash
fuse/relay box
Poor ground at G501
Cleanliness and tightness
of all connectors
The A/C condenser fan
does not run at all (but
A/C condenser fan circuit troubleshooting (see
A/C CONDENSER FAN CIRCUIT
Blown fuse No. 1 (30 A) in
the under-hood fuse/relay
box, and No. 14(10 A) in
the under-dash fuse/relay
box
2007 Honda Element EX
2007-2008 HVAC HVAC - Element
SYSTEM DESCRIPTION
HEATING/AIR CONDITIONING DOOR POSITIONS
radiator fan runs with
the A/C on)
TROUBLESHOOTING )
Poor ground at G201
Cleanliness and tightness
of all connectors
Both fans do not run
with the A/C on (but
the A/C compressor
runs with the A/Con)
Radiator and A/C condenser fans common
circuit troubleshooting (see RADIATOR
AND A/C CONDENSER FAN COMMON
CIRCUIT TROUBLESHOOTING )
Blown fuse No. 1 (30 A)
and No. 4 (20 A) in the
under-hood fuse/relay box,
and No. 14(10 A) in the
under-dash fuse/relay box
Poor ground at G201
Cleanliness and tightness
of all connectors
The A/C compressor
clutch does not engage
(but both fans run with
the A/C on)
A/C compressor clutch circuit troubleshooting
(see A/C COMPRESSOR CLUTCH
CIRCUIT TROUBLESHOOTING )
Blown fuse No. 1 (30 A) in
the under-hood fuse/relay
box, and No. 14 (10 A) in
the under-dash fuse/relay
box
Cleanliness and tightness
of all connectors
Blower motor operation
A/C system does not
come on (both fans and
the A/C compressor do
not work); heater is OK
A/C pressure switch circuit troubleshooting
(see A/C PRESSURE SWITCH CIRCUIT
TROUBLESHOOTING )
Cleanliness and tightness
of all connectors
Faulty evaporator
temperature sensor
2007 Honda Element EX
2007-2008 HVAC HVAC - Element
Fig. 9: Identifying Heating/Air Conditioning Door Positions (1 Of 2)
Courtesy of AMERICAN HONDA MOTOR CO., INC.
2007 Honda Element EX
2007-2008 HVAC HVAC - Element