Honda Element. Manual — part 368
Fig. 2: Fan Control Circuit Diagram
Courtesy of AMERICAN HONDA MOTOR CO., INC.
RADIATOR FAN CIRCUIT TROUBLESHOOTING
1. Check for the PGM-FI DTCs (see GENERAL TROUBLESHOOTING INFORMATION ).
Are DTC P2183, P2184, and/or P2185 indicated?
2007 Honda Element EX
2007-08 ENGINE Fan Controls - Element
YES - Do the appropriate troubleshooting, then recheck.
NO - Go to step 2.
2. Check the No. 4 (20 A), fuse in the under-hood fuse/relay box, and No. 14 (10 A), fuse in the under-dash
fuse/relay box.
Are the fuses OK?
YES - Go to step 3.
NO - Replace the fuse(s) and recheck.
3. Remove the radiator fan relay from the under-hood fuse/relay box, and test it (see POWER RELAY
TEST ).
Is the relay OK?
YES - Go to step 4.
NO - Replace the radiator fan relay.
4. Measure the voltage between the radiator fan relay 4P socket terminal No. 2 and body ground.
Fig. 3: Measuring Voltage Between Radiator Fan Relay 4P Socket Terminal No. 2 And Body
Ground
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there battery voltage?
YES - Go to step 5.
NO - Replace the under-hood fuse/relay box.
5. Connect the radiator fan relay 4P socket terminals No. 1 and No. 2 with a jumper wire.
2007 Honda Element EX
2007-08 ENGINE Fan Controls - Element
Fig. 4: Connecting Radiator Fan Relay 4P Socket Terminals No. 1 And 2 With Jumper Wire
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Does the radiator fan run?
YES - Go to step 9.
NO - Go to step 6.
6. Disconnect the radiator fan motor 2P connector.
7. Check for continuity between the radiator fan relay 4P socket terminal No. 1 and the radiator fan motor
2P connector terminal No. 2.
Fig. 5: Checking Continuity Between Radiator Fan Relay 4P Socket Terminal No. 1 And Radiator
Fan Motor 2P Connector Terminal No. 2
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES - Go to step 8.
NO - Repair open in the wire between the under-hood fuse/relay box and the radiator fan motor 2P
connector terminal No. 2.
8. Check for continuity between the radiator fan motor 2P connector terminal No. 1 and body ground.
2007 Honda Element EX
2007-08 ENGINE Fan Controls - Element
Fig. 6: Checking Continuity Between Radiator Fan Motor 2P Connector Terminal No. 1 And Body
Ground
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES - Replace the radiator fan motor.
NO - Repair open in the wire between radiator fan motor 2P connector terminal No. 1 and body ground.
If the wire is OK, check for a poor ground at G201.
9. Disconnect the jumper, and turn the ignition switch ON (II). Check for voltage between the radiator fan
relay 4P socket terminal No. 3 and body ground.
Fig. 7: Checking Voltage Between Radiator Fan Relay 4P Socket Terminal No. 3 And Body Ground
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there battery voltage?
YES - Go to step 10.
NO - Repair open in the wire between the under-hood fuse/relay box and under-dash fuse/relay box.
10. Check for continuity between the radiator fan relay 4P socket terminal No. 4 and the engine control
module (ECM)/powertrain control module (PCM) connector terminal E12.
2007 Honda Element EX
2007-08 ENGINE Fan Controls - Element
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст