Mitsubishi Colt Ralliart. Manual — part 363

SYMPTOM PROCEDURES

SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR

54B-196

Step 8. Check the wiring harness from B-134
ETACS-ECU connector terminal No.18 to C-11
luggage compartment lamp connector terminal
No.1

NOTE:

Prior to the wiring harness inspection, check interme-
diate connector C-02 and junction block connector
B-113 repair if necessary.

• Check the input and output lines for open circuit.

Q: Is the check result normal?

YES :

The trouble can be an intermittent

malfunction (Refer to GROUP 00

− How to

use Troubleshooting/inspection Service
Points

− How to Cope with Intermittent

Malfunction

P.00-13

).

NO :

Repair the wiring harness.

AC313826

Connector: B-134

AG

Junction block side

Junction block (Rear view)

AC401059

Connector: C-11

Harness side

AD

3

1

2

AC401057

Connector: C-02

AD

AC313824

Harness side

AB

Connector: B-113

Junction block (Front view)

Main

Index

Group

TOC

SYMPTOM PROCEDURES

SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR

54B-197

Step 9. Check the wiring harness from C-11
luggage compartment lamp connector terminal
No.2 to body earth.

NOTE:

Prior to the wiring harness inspection, check interme-
diate connector C-02 and junction block connector
B-113 and B-130 repair if necessary.

• Check the earth wires for open circuit.

Q: Is the check result normal?

YES :

The trouble can be an intermittent

malfunction (Refer to GROUP 00

− How to

use Troubleshooting/inspection Service
Points

− How to Cope with Intermittent

Malfunction

P.00-13

).

NO :

Repair the wiring harness.

AC401059

Connector: C-11

Harness side

AD

3

1

2

AC401057

Connector: C-02

AD

AC313824

Harness side

AB

Connector: B-113

Junction block (Front view)

AC313826

Harness side

AE

Connector: B-130

Junction block (Rear view)

Main

Index

Group

TOC

SYMPTOM PROCEDURES

SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR

54B-198

INSPECTION PROCEDURE M-4: The door-ajar warning lamp does not illuminate/extinguish normally.

CAUTION

Whenever the ECU is replaced, ensure that the
input and output signal circuits are normal.

COMMENTS ON TROUBLE SYMPTOM

If the door-ajar warning lamp does not work normally,
the input signal circuit or the ETACS-ECU may be
defective.

POSSIBLE CAUSES

• Malfunction of the all door switches

• Malfunction of the combination meter

• Malfunction of the CAN bus line

• Malfunction of the ETACS-ECU

• Damaged harness wires and connectors

DIAGNOSIS PROCEDURE

Step 1. Check the power supply circuit.
When the ignition switch is turned to the LOCK
(OFF) position, check if the hazard warning lamps
illuminate.

Q: Is the check result normal?

YES :

Go to Step 2.

NO :

Refer to Inspection Procedure A-2 "When
the ignition switch is at the LOCK (OFF)
position, the functions do not work normally.
Check the battery power supply circuit to
the ETACS-ECU

P.54B-43

."

Step 2. Pulse check
Check the input signals below which are related to
the door-ajar warning lamp.

OK: The M.U.T.-III sounds or the voltmeter
needle fluctuates.

Q: Is the check result normal?

All the signals are received normally. :

Go to Step

3.

The ignition switch (IG1) signal is not received. :

Refer to Inspection Procedure N-2 "The
ignition switch (IG1) signal is not received

P.54B-202

."

All the door switch signals are not received. :

Refer to Inspection Procedure N-10 "All the
door switch signals are not received

P.54B-219

."

Step 3. M.U.T.-III CAN bus diagnostics
Use the M.U.T.-III to diagnose the CAN bus lines.

Q: Is the check result normal?

YES :

Go to Step 4.

NO :

Repair the CAN bus line (Refer to GROUP
54D, Diagnosis

P.54D-13

).

ETACS-
ECU

SPEED SIGNAL

COMBINATION
METER

CAN COMMUNICATION LINE
(CAN_L LINE)

CAN COMMUNICATION LINE
(CAN_H LINE)

INPUT SIGNAL

INPUT SIGNAL

· IGNITION SWITCH (IG1)
· ALL DOOR SWITCH
· TAILGATE SWITCH

Door-Ajar Warning Lamp Function

System switch

Check condition

Ignition switch (IG1)

When turned from ACC
to ON

All of the door switches

A door is opened when
all the doors are closed

Main

Index

Group

TOC

SYMPTOM PROCEDURES

SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR

54B-199

Step 4. M.U.T.-III other system diagnosis code
Check whether the combination meter-related diag-
nosis code is set.

Q: Is the diagnosis code set?

YES :

Diagnose the combination meter (Refer to

GROUP 54A

− Troubleshooting

P.54A-31

).

NO :

Go to Step 5.

Step 5. M.U.T.-III actuator test
Perform the actuator test for the combination meter,
and check that the door-ajar warning lamp illumi-
nates (Refer to GROUP 54A

− Combination Meter

P.54A-62

).

Q: Is the check result normal?

YES :

Replace the ETACS-ECU.

NO :

Replace the combination meter.

Main