Mitsubishi Colt Ralliart. Manual — part 419
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-184
INSPECTION PROCEDURE L-4: The turn-signal indicator lamp does not illuminate.
CAUTION
Whenever the ECU is replaced, ensure that the
input and output signal circuits are normal.
COMMENTS ON TROUBLE SYMPTOM
If the turn-signal indicator lamp does not illuminate
normally, connector(s), wiring harness in the CAN
bus lines, the ETACS-ECU or the combination meter
may be defective.
POSSIBLE CAUSES
• Malfunction of the ETACS-ECU
• Malfunction of the combination meter
• Damaged harness wires and connectors
DIAGNOSIS PROCEDURE
Step 1. Check that the hazard warning lamps
operate.
Check that the hazard warning lamps illuminate nor-
mally.
Q: Is the check result normal?
YES :
Go to Step2.
NO :
Refer to Inspection Procedure L-2 "The
hazard warning lamps do not illuminate
normally
."
Step 2. M.U.T.-III CAN bus diagnostics
Use the M.U.T.-III to diagnose the CAN bus lines.
Q: Is the check result normal?
YES :
Go to Step3.
NO :
Repair the CAN bus line (Refer to GROUP
54D, Diagnosis
).
Step 3. M.U.T.-III other system diagnosis code.
Check whether the combination meter-related diag-
nosis code is set.
Q: Is the diagnosis code set?
YES :
Diagnose the combination meter (Refer to
GROUP 54A
− Troubleshooting
NO :
Go to Step 4.
Step 4. ECU check by using the SWS monitor
Check that the power supply and earth lines to the
ETACS-ECU and the SWS communication lines are
normal.
• Ignition switch: OFF
ECU TO BE CHECKED
• ETACS ECU
OK: "OK" is displayed on the "ETACS ECU"
menu.
Q: Is the check result normal?
YES :
Go to Step 5.
NO :
Refer to Inspection Procedure A-3
"Communication with ETACS-ECU is
impossible
INPUT SIGNAL
ETACS-ECU
COMBINATION
METER
CAN COMMUNICATION LINE
(CAN_L LINE)
CAN COMMUNICATION LINE
(CAN_H LINE)
· TURN-SIGNAL LAMP SWITCH
· HAZARD WARNING LAMP SWITCH
Turn-Signal Indicator Lamp Circuit
Main
Index
Group
TOC
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-185
Step 5. M.U.T.-III actuator test
Perform the actuator test for the combination meter,
and check that the turn-signal indicator lamps illumi-
nate (Refer to GROUP 54A
− Combination Meter
).
Q: Is the check result normal?
YES :
Replace the ETACS-ECU.
NO :
Replace the combination meter.
INSPECTION PROCEDURE L-5: The turn-signal lamps do not illuminate when the ignition switch is at
the ACC position.
CAUTION
Whenever the ECU is replaced, ensure that the
input and output signal circuits are normal.
COMMENTS ON TROUBLE SYMPTOM
If the turn-signal lamps do not illuminate with the igni-
tion switch at ACC, the input signal circuit from the
ignition switch (ACC) may be defective or the SWS
monitor customisation function has set "TURN-SIG-
NAL" to "IG-ON".
POSSIBLE CAUSES
• Malfunction of the column switch
• Malfunction of the ETACS-ECU
• Damaged harness wires and connectors
DIAGNOSIS PROCEDURE
Step 1. Customize function by using the SWS
monitor
Use the SWS monitor customisation function to con-
firm that "TURN-SIGNAL" is set to "IG-ACC."
Q: Is the check result normal?
YES :
Go to Step 2.
NO :
Use the SWS monitor customisation
function to set "TURN-SIGNAL" to
"IG-ACC." Refer to
.
Step 2. Check that the turn-signal lamps operate.
Check that the turn-signal lamps illuminate normally
when the ignition switch is turned to the ON position.
Q: Is the check result normal?
YES :
Go to Step 3.
NO :
Refer to Inspection Procedure L-1 "The
turn-signal lamps do not illuminate normally
."
Step 3. SWS monitor data list
Check the ETACS-ECU signals which are related to
the turn-signal lamp illumination when the ignition
switch is at the ACC position.
<Selected item> ETACS-ECU
• Ignition switch: ACC position
OK: Normal condition is displayed.
Q: Is the check result normal?
YES :
Go to Step 4.
NO :
Refer to inspection procedure N-1 "The
Ignition switch (ACC) signal is not received
."
Step 4. Retest the system.
Check whether the turn-signal lights illuminate.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
− How to
use Troubleshooting/inspection Service
Points
− How to Cope with Intermittent
).
NO :
Replace the ETACS-ECU.
Item No.
Item name
Normal
condition
Item 31
IG SW (ACC)
ON
Main
Index
Group
TOC
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-186
INTERIOR LAMP
INSPECTION PROCEDURE M-1: The interior lamps (room ramp, luggage compartment lamp) does not
illuminate or extinguish normally.
CAUTION
Whenever the ECU is replaced, ensure that the
input and output signal circuits are normal.
COMMENTS ON TROUBLE SYMPTOM
The ETACS-ECU operates the interior lamps (room
lamp, luggage compartment lamp) in accordance
with the input signals below.
• Ignition switch (IG1)
• Key reminder switch
• All of the door switches
• Driver's door lock actuator
If this function does not work normally, these input
signal circuit(s) or the ETACS-ECU may be defec-
tive. Alternatively, it is possible that "RM LMP TN
OFF" was set to "W/O FUNCTION" by using the
SWS monitor customisation function.
POSSIBLE CAUSES
• Malfunction of the key reminder switch
• Malfunction of the door switches
• Malfunction of the driver's door lock actuator
• Malfunction of the ETACS-ECU
• Damaged harness wires and connectors
DIAGNOSIS PROCEDURE
Step 1. Customize function by using the SWS
monitor
Use the SWS monitor customisation function to con-
firm that "RM LMP TN OFF" is set to "7.5s", "15s",
"30s" or "60s".
Q: Is the check result normal?
YES :
Go to Step 2.
NO :
Use the SWS monitor customisation
function to set "RM LMP TN OFF" to "7.5s",
"15s", "30s" or "60s". Refer to
· KEY CYLINDER
· ROOM LAMP
· LUGGAGE
COMPARTMENT
LAMP
ILLUMINATION
LAMP
J/B SIDE
ETACS-ECU
POWER SOURCE
FUSIBLE
LINK
1
Interior Lamp Circuit
Wire colour code
B : Black LG : Light green G : Green L : Blue W : White Y : Yellow SB : Sky blue
BR : Brown O : Orange GR : Gray R : Red P : Pink V : Violet
IGNITION
SWITCH (IG1)
Main
Index
Group
TOC
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-187
Step 2. ECU check by using the SWS monitor
Check that the power supply and earth lines to the
ETACS-ECU and the SWS communication lines are
normal.
• Ignition switch: OFF
ECU TO BE CHECKED
• ETACS ECU
OK: "OK" is displayed on the "ETACS ECU"
menu.
Q: Is the check result normal?
YES :
Go to Step 3.
NO :
Refer to Inspection Procedure A-3
"Communication with the ETACS-ECU is
not possible
Step 3. SWS monitor data list
Check the SWS communication line signals related
to the room lamp and the luggage compartment lamp
illuminations.
<Selected item> ETACS
• Ignition switch: OFF
• Driver's door: open
OK: Normal conditions are displayed for all
the items.
Q: Is the check result normal?
Normal conditions are displayed for all the items. :
Go to Step 4.
Normal condition is not displayed for item No.30 :
Refer to inspection procedure N-2 "The
ignition switch (IG1) signal is not received
."
Normal condition is not displayed for item No.32 :
Refer to inspection procedure N-3 "The
driver's door switch signal is not received
."
Step 4. ETACS switch data by using the SWS
monitor
Check the ETACS-ECU signals related to the illumi-
nation of the room lamp and the luggage compart-
ment lamp.
• Ignition switch: OFF (key inserted)
• Doors other than the driver's door: Closed to
open
• Driver's door lock actuator switch: UNLOCK →
LOCK
OK: Normal conditions are displayed for all
the items.
Q: Is the check result normal?
Normal conditions are displayed for all the items. :
Go to Step 5.
Normal condition is not displayed for item No.03 :
Refer to inspection procedure N-7 "The key
reminder switch signal is not received
."
Normal condition is not displayed for item No.40 :
Refer to inspection procedure N-10 "All the
door switch signals are not received
."
Normal condition is not displayed for item No.21 or
22 :
Refer to inspection procedure N-11 "The
driver's door lock actuator switch signal is
not received
Step 5. Check of the troubles
When the room lamp and the luggage compartment
lamp switches are set to the DOOR or ON position,
the room lamp and the luggage compartment lamp
should illuminate normally.
Q: Is the check result normal?
The lamp illuminates at neither the ON nor DOOR
position. :
Go to Step 6.
The lamp does not illuminate at the DOOR position.
:
Go to Step 8.
The lamp does not illuminate at the ON position. :
Go to Step 10.
Item No.
Item name
Normal
condition
Item 30
IG SW(IG1)
OFF
Item 32
DR DOOR SW
ON
Item No.
Item name
Normal
condition
Item 03
KEY REMIN SW
OFF
Item 40
ALL DOOR SW
from ON
to OFF
Item No.
Item name
Normal
condition
Item 21
DR DOR LCK SW
from OFF
to ON
Item 22
DR DOR ULK SW
from ON
to OFF
Main
Index
Group
TOC