Mitsubishi 380. Manual — part 215
HEATER UNIT, HEATER CORE, BLOWER ASSEMBLY AND EVAPORATOR UNIT
HEATER, AIR CONDITIONING AND VENTILATION
55-156
BLOWER ASSEMBLY DISASSEMBLY AND ASSEMBLY
M1551005500209
25DB064A
1
2
3
5
4
DISASSEMBLY STEPS
1.
OUTSIDE/INSIDE AIR
SELECTION DAMPER CONTROL
MOTOR
2.
POWER TRANSISTOR
3.
BLOWER MOTOR
4.
BLOWER CASE UPPER
5.
BLOWER CASE LOWER
DISASSEMBLY STEPS
MOTORS AND TRANSISTOR
HEATER, AIR CONDITIONING AND VENTILATION
55-157
MOTORS AND TRANSISTOR
REMOVAL AND INSTALLATION
M1551006900028
AC209768
25DB065A
1
2
3
4
MODE SELECTION DAMPER
CONTROL MOTOR REMOVAL
STEP
1.
MODE SELECTION DAMPER
CONTROL MOTOR
POWER TRANSISTOR REMOVAL
STEP
•
GLOVE BOX ASSEMBLY,
INSTRUMENT CENTER PANEL
ASSEMBLY (REFER TO GROUP
52A, INSTRUMENT PANEL
).
2.
POWER TRANSISTOR
BLOWER MOTOR REMOVAL
STEP
3.
BLOWER MOTOR
OUTSIDE/INSIDE AIR
SELECTION DAMPER MOTOR
REMOVAL STEP
•
GLOVE BOX ASSEMBLY,
INSTRUMENT CENTER PANEL
ASSEMBLY (REFER TO GROUP
52A, INSTRUMENT PANEL
).
4.
OUTSIDE/INSIDE AIR
SELECTION DAMPER MOTOR
MOTORS AND TRANSISTOR
HEATER, AIR CONDITIONING AND VENTILATION
55-158
INSPECTION
M1551006300338
.
MODE SELECTION DAMPER CONTROL MOTOR
CHECK
CAUTION
Do not apply battery voltage when the damper is in the
FACE or DEF position.
Check the mode selection damper control motor by the follow-
ing procedures.
.
POTENTIOMETER CHECK
While checking the mode selection damper control motor, mea-
sure the resistances between terminal numbers 3 and 5 and
between terminal numbers 3 and 7. At this time, the resis-
tances should change gradually within the standard value.
Standard value: 0.8 (DEF)
− 4.8 (FACE) kΩ
.
OUTSIDE/INSIDE AIR SELECTION DAMPER
CONTROL MOTOR CHECK
CAUTION
Cut off the battery voltage when the damper is in the
inside/outside air position.
Check the outside/inside air selection damper control motor by
the following procedures.
LEVER POSITION BATTERY
CONNECTION
LEVER
OPERATION
At the FACE
position
• Connect
terminal 2 to the
positive battery
terminal
• Connect
terminal 1 to the
negative battery
terminal
The lever moves
from the FACE
position to the DEF
position
At the DEF position
• Connect
terminal 1 to the
positive battery
terminal
• Connect
terminal 2 to the
negative battery
terminal
The lever moves
from the DEF
position to the
FACE position
25DB066A
FACE POSITION
DEF POSITION
1 2
4
3
5
7
6
25DB067A
OUTSIDE POSITION
INSIDE POSITION
C-106
MOTORS AND TRANSISTOR
HEATER, AIR CONDITIONING AND VENTILATION
55-159
.
BLOWER FAN AND MOTOR CHECK
When battery voltage is applied between the terminals, check
that the motor operates. Also, check that there is no abnormal
noise.
LEVER POSITION BATTERY
CONNECTION
LEVER
OPERATION
At the inside
position
• Connect
terminal 1 to the
positive battery
terminal
• Connect
terminal 7 to the
negative battery
terminal
The lever moves
from the outside
position to the
inside position
At the outside
position
• Connect
terminal 1 to the
positive battery
terminal
• Connect
terminal 5 to the
negative battery
terminal
The lever moves
from the inside
position to the
outside position
AC209862