Mitsubishi 380. Manual — part 901
COMBINATION METER ASSEMBLY
CHASSIS ELECTRICAL
54A-138
STEP 11. Check the wiring harness and terminals between
combination meter connector C-101 (terminal 17) and the
mode switch connector C-32 (terminal 2)
Q: Is the wiring harness between combination meter
connector C-101 (terminal 17) and the mode switch
connector C-32 (terminal 2) in good condition?
YES : Go to Step 12.
NO : Repair the wiring harness. Check that the mode
switch functions normally.
COMBINATION METER ASSEMBLY
CHASSIS ELECTRICAL
54A-139
STEP 12. Measure the resistance between the combination
meter connector C-101 (terminal 17) and the mode switch
connector C-32 (terminal 2).
(1) Disconnect the combination meter connector C-101 and the
mode switch connector C-32.
(2) Measure resistance between combination meter C-101
(terminal 17) and mode switch connector C-32 (terminal 2).
• The measured value should be 2 ohm or less.
Q: Is the measured resistance 2 ohms or less?
YES : Go to Step 13.
NO : Repair the wiring circuit and check the mode switch
16DB587A
CONNECTOR: C-32
54DB019A
CONNECTOR: C-101
HARNESS SIDE
16DB591A
CONNECTOR: C-101, C-32
C-101
C-32
COMBINATION METER ASSEMBLY
CHASSIS ELECTRICAL
54A-140
STEP 13. Check the wiring harness and terminals between
combination meter connector C-101 (terminal 18) and the
mode switch connector C-32 (terminal 5)
Q: Is the wiring harness between combination meter
connector C-101 (terminal 18) and the mode switch
connector C-32 (terminal 5) in good condition?
YES : Go to Step 14.
NO : Repair the wiring harness. Check that the mode
switch functions normally.
COMBINATION METER ASSEMBLY
CHASSIS ELECTRICAL
54A-141
STEP 14. Measure the resistance between the combination
meter connector C-101 (terminal 18) and the mode switch
connector C-32 (terminal 5).
(1) Disconnect the combination meter connector C-101 and the
mode switch connector C-32.
(2) Measure resistance between combination meter C-101
(terminal 18) and mode switch connector C-32 (terminal 5).
• The measured value should be 2 ohm or less.
Q: Is the measured resistance 2 ohms or less?
YES : Replace combination meter and retest mode switch
function.
NO : Repair the wiring circuit and check the mode switch
16DB587A
CONNECTOR: C-32
54DB019A
CONNECTOR: C-101
HARNESS SIDE
16DB592A
CONNECTOR: C-101, C-32
C-101
C-32
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.