Mitsubishi 380. Manual — part 31
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)
54B-121
If the passenger's door or driver's door are locked
while the passenger's door is open and when the key
is still in the ignition key cylinder, approximately 0.3
second later the ETACS-ECU activates the unlock
relay output for 0.25 second to prevent the door from
being locked with the key inside the vehicle.
In addition, if locking the door was not prevented, a
re-try current is sent (an unlock relay output ON is
sent for 0.25 second up to 5 times including the first
attempt).
NOTE: The dotted line indicates that the system is
trying to turn on the unlock relay if the door cannot be
unlocked.
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)
54B-122
INSPECTION PROCEDURE C-1: Central Door Locking System: The Central Door Locking System
does not Work at all.
NOTE: This troubleshooting procedure requires the
use of diagnostic tool MB991958 and SWS monitor
kit MB991813. For details on how to use the SWS
monitor, refer to "How to connect SWS monitor
."
.
CIRCUIT OPERATION
• The ETACS-ECU controls the central door lock
system, locking or unlocking all the doors by acti-
vating the central door lock relay (built into the
ETACS-ECU). The ETACS-ECU uses inputs from
the following components:
• Front door lock actuator
• Front door lock key cylinder switch
• Door lock switch, which is incorporated in the
power window main switch or front power win-
dow sub switch
.
TROUBLESHOOTING HINTS
• Refer to circuit diagrams GROUP-
• Refer to configuration diagrams GROUP-
• The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
• The ETACS-ECU may be defective
AC305015AD
FUSIBLE LINK (1)
16DB305A
C-219
C-217
CONNECTORS: C-217, C-219
JUNCTION BLOCK
(REAR VIEW)
16DB309A
E-05 (B)
CONNECTOR: E-05
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)
54B-123
DIAGNOSIS
Required Special Tools:
• MB991223: Harness Set
• MB991958: diagnostic tool (MUT-III Sub Assembly)
• MB991824: Vehicle Communication Interface (V.C.I.)
• MB991827: MUT-III USB Cable
• MB991910: MUT-III Main Harness A
• MB991813: SWS Monitor Kit
• MB991806: SWS Monitor Cartridge
• MB991812: SWS Monitor Harness (For Column-ECU)
• MB991822: Test Probe Harness
STEP 1. Use diagnostic tool MB991958 to select "ECU
COMM Check" on the SWS monitor display.
Check the ETACS-ECU.
CAUTION
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958. Connect special tool MB991910 before con-
necting special tool MB991812. Be sure to connect special
tool MB991806 after turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
monitor
."
(2) Turn the ignition switch to the "LOCK" (OFF) position.
(3) Operate diagnostic tool MB991958 according to the
procedure below to display "ECU COMM Check."
a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "ECU COMM Check."
(4) MUT-III should show "OK" on the "ECU COMM Check"
menu for the "ETACS ECU" menu.
Q: Is "OK" displayed for the "ETACS ECU" menu?
YES : Go to Step 2.
NO : Refer to Inspection Procedure A-3 "Communication
with the ETACS-ECU is not possible
."
00DB076A
MB991910
DATA LINK
CONNECTOR
MB991824
MB991827
COLUMN SWITCH
CONNECTOR
COLUMN SWITCH
CONNECTOR AT
HARNESS SIDE
MB991812
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)
54B-124
STEP 2. Check ETACS-ECU connector C-219 for loose,
corroded or damaged terminals, or terminals pushed back
in the connector.
Q: Is ETACS-ECU connector C-219 in good condition?
YES : Go to Step 3.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
. Verify that the central door locking system
works normally.
STEP 3. Check the battery power supply circuit to the
ETACS-ECU. Measure the voltage at ETACS-ECU
connector C-219.
(1) Disconnect ETACS-ECU connector C-219 and measure the
voltage available at the junction block side of the connector.
(2) Measure the voltage between terminal 2 and ground.
• The voltage should measure approximately 12 volts
(battery positive voltage)
Q: Is the measured voltage approximately 12 volts (battery
positive voltage)?
YES : Go to Step 5.
NO : Go to Step 4.
54DB014A
CONNECTOR: C-219
JUNCTION BLOCK SIDE
JUNCTION BLOCK
(REAR VIEW)
54DB014A
CONNECTOR: C-219
JUNCTION BLOCK SIDE
JUNCTION BLOCK
(REAR VIEW)
AC209365EO
(JUNCTION BLOCK SIDE)
CONNECTOR C-219