Mitsubishi 380. Manual — part 694
DIAGNOSIS
CONTROLLER AREA NETWORK (CAN)
54C-186
DIAGNOSIS
Required Special Tools:
• MB991223: Harness Set
• MB991219: Inspection Test Harness
• MB992045: A/T-ECU Check Harness
STEP 1. Check ENGINE- ECU connector B-21, combination
meter connector C-101 and data link connector C-125 for
loose, corroded or damaged terminals, or terminals
pushed back in the connector.
CAUTION
The strand end of the twisted wire should be within 10 cm
(4 inches) from the connector. For details refer to
Q: Are ENGINE- ECU connector B-21, combination meter
connector C-101 and data link connector C-125 in good
condition?
YES : Go to Step 2.
NO : Repair the damaged parts.
16DB400A
COVER
ENGINE
CONTROL
UNIT
AIR
CLEANER
16DB475A
CONNECTORS: C-101, C-125
C-101
C-125
C-125 (B)
C-101 HARNESS SIDE
DIAGNOSIS
CONTROLLER AREA NETWORK (CAN)
54C-187
STEP 2. Check the CAN_H-side bus line (communication
line including ECUs) for short to ground. Measure the
resistance at data link connector C-125.
CAUTION
A digital multimeter should be used. For details refer to
CAUTION
The test wiring harness should be used. For details refer to
(1) Disconnect ENGINE- ECU connector B-21 and combination
meter connector C-101, and measure the resistance at the
harness side of data link connector C-125.
(2) Turn the ignition switch to the "LOCK" (OFF) position.
CAUTION
Disconnect the negative battery terminal. For details refer
to
.
(3) Disconnect the negative battery terminal.
16DB400A
COVER
ENGINE
CONTROL
UNIT
AIR
CLEANER
16DB475A
CONNECTORS: C-101, C-125
C-101
C-125
C-125 (B)
C-101 HARNESS SIDE
DIAGNOSIS
CONTROLLER AREA NETWORK (CAN)
54C-188
(4) Measure the resistance between data link connector
terminal 6 and body ground.
OK: 1 k
Ω or more
Q: Does the resistance measure 1 k
Ω or more?
YES : If the resistance measures 1 k
Ω or more, go to Step 3
.
NO : If the resistance measures less than 1 k
Ω, go to Step
AC209364
Y
8
16
15
7
5
1314
6
12
4
2
1011
3
9
1
AC209364
AC209364
AC209364
AC209364
AC209364HT
HARNESS SIDE: C-125
TEST
HARNESS
DIAGNOSIS
CONTROLLER AREA NETWORK (CAN)
54C-189
STEP 3. Check the CAN_L-side bus line (communication
line including ECUs) for short to ground. Measure the
resistance at data link connector C-125.
CAUTION
A digital multimeter should be used. For details refer to
CAUTION
The test wiring harness should be used. For details refer to
(1) Disconnect ENGINE- ECU connector B-21 and combination
meter connector C-101, and measure the resistance at the
harness side of data link connector C-125.
(2) Turn the ignition switch to the "LOCK" (OFF) position.
CAUTION
Disconnect the negative battery terminal. For details refer
to
.
(3) Disconnect the negative battery terminal.
16DB400A
COVER
ENGINE
CONTROL
UNIT
AIR
CLEANER
16DB475A
CONNECTORS: C-101, C-125
C-101
C-125
C-125 (B)
C-101 HARNESS SIDE