Mitsubishi Outlander (2003+). Manual — part 534
TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION
55A-31
Q: Is the check result normal?
YES :
Go to Step 21.
NO :
Go to Step 6.
STEP 6. Check the blower relay continuity.
Refer to
Q: Is the blower relay continuity in good condition?
YES :
Go to Step 7.
NO :
Replace the blower relay.
STEP 7. Measure the voltage at C-207 blower
relay connector.
(1) Remove the relay, and measure at the junction
block side.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between terminal 1 and
earth.
OK: System voltage
Q: Is the check result normal?
YES :
Go to Step 10.
NO :
Go to Step 8.
STEP 8. Connector check: C-207 blower relay
connector
Q: Is the check result normal?
YES :
Go to Step 9.
NO :
Repair the connector.
STEP 9. Check the wiring harness between C-207
blower relay connector terminal No.1 and the
ignition switch (IG2).
NOTE: Prior to the wiring harness inspection, check
junction block connector C-203, and repair if
necessary.
•
Check the blower relay power supply line for
open circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
AC210474
Connector: C-207
AJ
Junction block (Front view)
3
4
5
1
2
Junction block side
AC301541CB
Connector C-207
(Junction block side)
3
4
5
1
2
AC210474
Connector: C-207
AJ
Junction block (Front view)
3
4
5
1
2
Junction block side
AC210475
Connectors: C-203, C-207
AS
Junction block (Front view)
C-207
C-203
Harness side
C-203
4
6 5
3
2
1
3
4
5
1
2
Junction block side
C-207
TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION
55A-32
STEP 10. Measure the resistance at C-207 blower
relay connector.
(1) Remove the relay, and measure at the junction
block side.
(2) Measure the resistance Continuity between
terminal 3 and body earth.
OK: 2 ohm or less
Q: Is the check result normal?
YES :
Go to Step 13.
NO :
Go to Step 11.
STEP 11. Connector check: C-207 blower relay
connector.
Q: Is the check result normal?
YES :
Go to Step 12.
NO :
Repair the connector.
STEP 12. Check the wiring harness between
C-207 blower relay connector terminal No.3 and
earth.
NOTE: Prior to the wiring harness inspection, check
junction block connectors C-205, and repair if neces-
sary.
•
Check the blower relay earth wires for open cir-
cuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
AC210474
Connector: C-207
AJ
Junction block (Front view)
3
4
5
1
2
Junction block side
AC301541CC
Connector C-207
(Junction block side)
3
4
5
1
2
AC210474
Connector: C-207
AJ
Junction block (Front view)
3
4
5
1
2
Junction block side
AC210475
Connectors: C-205, C-207
AT
Junction block (Front view)
C-207
C-205
Harness side
C-205
3
4
5
1
2
Junction block side
C-207
21
7
16 15
17
18
20 19
1
2
3
4
5
6
23 22
24
25
28
26
27
9
8
10
11
14
12
13
TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION
55A-33
STEP 13. Measure the voltage at C-207 blower
relay connector.
(1) Remove the relay, and measure at the junction
block side.
(2) Measure the voltage between terminal 5 and
body earth.
OK: System voltage
Q: Is the check result normal?
YES :
Go to Step 16.
NO :
Go to Step 14.
STEP 14. Connector check: C-207 blower relay
connector
Q: Is the check result normal?
YES :
Go to Step 15.
NO :
Repair the connector.
STEP 15. Check the wiring harness between
C-207 blower relay connector terminal No.5 and
fusible link (1).
NOTE:
Prior to the wiring harness inspection, check interme-
diate connectors C-116 and junction block connector
C-204, and repair if necessary.
•
Check the blower relay power supply line for
open circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
STEP 16. Check the blower switch continuity.
.
Q: Is the blower switch continuity in good condition?
YES :
Go to Step 17.
NO :
Replace the blower switch.
AC210474
Connector: C-207
AJ
Junction block (Front view)
3
4
5
1
2
Junction block side
AC301541CD
Connector C-207
(Junction block side)
3
4
5
1
2
AC210474
Connector: C-207
AJ
Junction block (Front view)
3
4
5
1
2
Junction block side
AC210475
Connectors: C-204, C-207
AU
Junction block (Front view)
C-207
C-204(B)
Harness side
C-204
3
4
5
1
2
Junction block side
C-207
1
AC301395AG
9
21
33
35
24
12
3 4
7
8
5 6
39
28
41
30
18
4243
31
1920
32
40
29
1617
38
27
15
37
36
26
14
13
25
2
1
34
23
11
10
22
Connector: C-116
TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION
55A-34
STEP 17. Connector check: C-08 blower switch
connector and C-207 blower relay connector
Q: Is the check result normal?
YES :
Go to Step 18.
NO :
Repair the connector.
STEP 18. Check the wiring harness between C-08
blower switch connector terminal No.2 and C-207
blower relay connector terminal No.4.
NOTE: Prior to the wiring harness inspection, check
junction block connectors C-203, and repair if
necessary.
•
Check the blower relay output line for open
circuit.
Q: Is the check result normal?
YES :
Go to Step 19.
NO :
Repair the wiring harness.
AC301397
Connector: C-08
AR
Harness side
2
5
6
3
4
1
AC210474
Connector: C-207
AJ
Junction block (Front view)
3
4
5
1
2
Junction block side
AC301397
Connector: C-08
AR
Harness side
2
5
6
3
4
1
AC210475
Connectors: C-203, C-207
AS
Junction block (Front view)
C-207
C-203
Harness side
C-203
4
6 5
3
2
1
3
4
5
1
2
Junction block side
C-207
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.