Mitsubishi Outlander (2003+). Manual — part 562
TROUBLESHOOTING
AUTOMATIC AIR CONDITIONER
55B-63
Step 12. Check the wiring harness between C-207
blower relay connector terminal No.3 and body
earth.
NOTE: Prior to the wiring harness inspection, check
junction block connector C-205, and repair if
necessary.
•
Check the blower relay earth wires for open
circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
Step 13. Connector check: C-207 blower relay
connector and C-32 blower linear controller
connector
Q: Is the check result normal?
YES :
Go to Step 14.
NO :
Repair the connector.
AC210475
Connectors: C-205, C-207 <LHD>
BG
Junction block (Front view)
C-207
C-205
Harness side
C-205
3
4
5
1
2
Junction block side
C-207
21
7
16 15
17
18
20 19
1
2
3
4
5
6
23 22
24
25
28
26
27
9
8
10
11
14
12
13
AC308773
Connectors: C-205, C-207 <RHD>
AY
Junction block (Front view)
C-207
C-205
Harness side
C-205
3
4
5
1
2
Junction block side
C-207
21
7
16 15
17
18
20 19
1
2
3
4
5
6
23 22
24
25
28
26
27
9
8
10
11
14
12
13
AC210474
Connector: C-207 <LHD>
AN
Junction block (Front view)
3
4
5
1
2
Junction block side
AC308772
Connector: C-207 <RHD>
AO
Junction block (Front view)
3
4
5
1
2
Junction block side
AC301397
Connector: C-32
<LHD>
BE
Harness side
4
6 5
3
2
1
AC308735
Connector: C-32 <RHD>
BF
Harness side
4
6 5
3
2
1
TROUBLESHOOTING
AUTOMATIC AIR CONDITIONER
55B-64
Step 14. Check the wiring harness between C-207
blower relay connector terminal No.4 and C-32
blower linear controller connector terminal No.6.
NOTE: Prior to the wiring harness inspection, check
junction block connector C-203, and repair if
necessary.
•
Check the blower linear controller power supply
line for open circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
AC210475
Connectors: C-203, C-207 <LHD>
BE
Junction block (Front view)
C-207
C-203
Harness side
C-203
4
6 5
3
2
1
3
4
5
1
2
Junction block side
C-207
AC308773
Connectors: C-203, C-207 <RHD>
AW
Junction block (Front view)
C-207
C-203
Harness side
C-203
4
6 5
3
2
1
3
4
5
1
2
Junction block side
C-207
AC301397
Connector: C-32
<LHD>
BE
Harness side
4
6 5
3
2
1
AC308735
Connector: C-32 <RHD>
BF
Harness side
4
6 5
3
2
1
TROUBLESHOOTING
AUTOMATIC AIR CONDITIONER
55B-65
Step 15. Measure the resistance at the C-32
blower linear controller connector.
(1) Disconnect the connector, and measure at the
wiring harness side.
(2) Continuity between terminal 3 and body earth
OK: 2
Ω
or less
Q: Is the check result normal?
YES :
Go to Step 18.
NO :
Go to Step 16.
Step 16. Connector check: C-32 blower liner
controller
Q: Is the check result normal?
YES :
Go to Step 17.
NO :
Repair the connector.
AC301397
Connector: C-32
<LHD>
BE
Harness side
4
6 5
3
2
1
AC308735
Connector: C-32 <RHD>
BF
Harness side
4
6 5
3
2
1
AC301541CJ
Connector C-32
(Harness side)
4
6 5
3
2
1
AC301397
Connector: C-32
<LHD>
BE
Harness side
4
6 5
3
2
1
AC308735
Connector: C-32 <RHD>
BF
Harness side
4
6 5
3
2
1
TROUBLESHOOTING
AUTOMATIC AIR CONDITIONER
55B-66
Step 17. Check the wiring harness between C-32
blower linear controller connector terminal No.3
and body earth.
•
Check the blower linear controller earth line for
open circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
Step 18. Connector check: C-27 A/C-ECU
connector and C-32 blower linear controller
connector
Q: Is the check result normal?
YES :
Go to Step 19.
NO :
Repair the connector.
AC301397
Connector: C-32
<LHD>
BE
Harness side
4
6 5
3
2
1
AC308735
Connector: C-32 <RHD>
BF
Harness side
4
6 5
3
2
1
AC301398
Connectors: C-27, C-32 <LHD>
C-32
BP
C-32
Harness side
C-27
C-27(B)
4
6 5
3
2
1
8
2
10 9
1
5
3
4
6
7
20191817161514131211
Harness side
AC308736
Connectors: C-27, C-32 <RHD>
AO
C-32
Harness side
Harness side
C-27
C-32
C-27(B)
4
6 5
3
2
1
8
2
10 9
1
5
3
4
6
7
20191817161514131211
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст