Mitsubishi Grandis. Manual — part 272
INPUT SIGNAL PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-550
DIAGNOSIS PROCEDURE
Step 1. Connector check: C-129 remote
controlled mirror switch connector
Q: Is the check result normal?
YES :
Go to Step 2.
NO :
Repair the connector.
Step 2. Check the remote controlled mirror
switch.
Refer to GROUP 51
− Door mirror
.
Q: Is the check result normal?
YES :
Go to Step 3.
NO :
Replace the remote controlled mirror switch.
Step 3. Resistance measurement at the C-129
remote controlled mirror switch connector.
(1) Disconnect the connector, and measure at the
wiring harness side.
(2) Continuity between C-129 remote controlled
mirror switch connector terminal No.1 and body
earth
OK: 2
Ω or less
Q: Is the check result normal?
YES :
Go to Step 5.
NO :
Go to Step 4.
AC312031
AB
Connector: C-129
Harness side
<LHD>
AC312043AB
Connector: C-129 <RHD>
Harness side
AC312031
AB
Connector: C-129
Harness side
<LHD>
AC312043AB
Connector: C-129 <RHD>
Harness side
AC312730AC
Connector C-129
(Harness side)
INPUT SIGNAL PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-551
Step 4. Check the wiring harness between C-129
remote controlled mirror switch connector
terminal No.1 and body earth.
NOTE:
Prior to the wiring harness inspection, check joint
connector C-01 <RH drive vehicles>, and repair if
necessary.
• Check the earth wires for open circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
− How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
Step 5. Connector check: C-220 ETACS-ECU
connector
Q: Is the check result normal?
YES :
Go to Step 6.
NO :
Repair the connector.
AC312031
AB
Connector: C-129
Harness side
<LHD>
AC312043AB
Connector: C-129 <RHD>
Harness side
AC312043AC
Connector: C-01<RHD>
AC312037
Connector: C-220
Junction block (Rear view)
AC
<LHD>
Harness side
AC312047
Connector: C-220
Junction block (Rear view)
AC
<RHD>
Harness side
INPUT SIGNAL PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-552
Step 6. Check the wiring harness between C-129
remote controlled mirror switch connector
terminal No.4 and C-220 ETACS-ECU connector
terminal No.24.
• Check the input line for open circuit.
Q: Is the check result normal?
YES :
Go to Step 7.
NO :
Repair the wiring harness.
Step 7. ETACS switch data by using the SWS
monitor
Check the input signal from the remote controlled
mirror switch.
• Ignition switch: ON
• Remote controlled mirror (folding/unfolding)
switch: from OFF to ON
OK: Normal condition is displayed.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
− How to
Cope with Intermittent Malfunction
NO :
Replace the ETACS-ECU.
AC312031
AB
Connector: C-129
Harness side
<LHD>
AC312043AB
Connector: C-129 <RHD>
Harness side
AC312037
Connector: C-220
Junction block (Rear view)
AC
<LHD>
Harness side
AC312047
Connector: C-220
Junction block (Rear view)
AC
<RHD>
Harness side
Item No. Item name
Normal conditions
Item 14
EL RET MIR SW OFF to ON (only
when switch is
operated)
INPUT SIGNAL PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-553
Inspection Procedure Q-22: The interior lamp "all on" or "all off" switch signal is not sent to the
ETACS-ECU.
CAUTION
Whenever the ECU is replaced, ensure that the
input signal circuit is normal.
COMMENTS ON TROUBLE SYMPTOM
Input signals from the interior lamp switches are
used to operate the interior lamps. If the signals are
abnormal, the interior lamps will not illuminate and
extinguish normally.
POSSIBLE CAUSES
• Malfunction of the interior lamp
• Malfunction of the ETACS-ECU
• Damaged harness wires and connectors
ETACS-ECU
ROOM LAMP
NOTE
Wire colour code
B : Black LG : Light green G : Green L : Blue W : White Y : Yellow SB : Sky blue
BR : Brown O : Orange GR : Gray R : Red P : Pink V : Violet
RHD
LHD
Interior Lamp Input Circuit
INTERIOR
LAMP
SWITCH
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.