Mitsubishi Grandis. Manual — part 72

SYMPTOM PROCEDURES

SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR

54B-285

(1) Disconnect the connector, and measure at the

wiring harness side.

(2) Check the resistance between the lamp

AC310403

A-17 (GR)

AD

Connector: A-17 <LHD>

AC310398

A-17 (GR)

AD

Connector: A-17 <RHD>

AC310401

Connector: A-39 <LHD>

Harness side

A-39 (GR)

AB

AC310396

Connector: A-39 <RHD>

Harness side

A-39 (GR)

AB

AC310223

Connectors: G-08, G-15, G-19

AC

Harness side

G-08

G-15

G-19

G-08

Harness side

G-15

Harness side

G-19

AC310220

AD

Connector: G-20

Harness side

SYMPTOM PROCEDURES

SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR

54B-286

connector and body earth.

Resistance between A-39 position lamp (RH)

connector terminal No.1 and body earth

• Resistance between A-17 position lamp (LH)

connector terminal No.1 and body earth

Resistance between G-08 tail/stop lamp (RH)

connector terminal No.1 and body earth

• Resistance between G-20 tail/stop lamp (LH)

connector terminal No.1 and body earth

Resistance between G-15 licence plate lamp

(RH) connector terminal No.1 and body earth

• Resistance between G-19 licence plate lamp

(LH) connector terminal No.1 and body earth

OK: 2

or less

Q: Is the check result normal?

YES :

Go to Step 5.

NO :

Go to Step 4.

Step 4. Connector check: A-25 earth connector
<position lamp>

Q: Is the check result normal?

YES :

Go to Step 5.

NO :

Repair the defective connector.

AC310506AW

Connector A-17, A-39
(Harness side)

AC310506AX

Connector G-08, G-20
(Harness side)

AC301541HZ

Connector G-15, G-19
(Harness side)

AC310403

A-25 (GR)

AE

Connector: A-25 <LHD>

Harness side

AC310398

A-25 (GR)

AE

Connector: A-25 <RHD>

Harness side

SYMPTOM PROCEDURES

SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR

54B-287

Step 5. Check the wiring harness from G-08
tail/stop lamp (RH) connector terminal No.1 or
G-20 tail/stop lamp (LH) connector terminal No.1
or G-15 licence plate lamp (RH) connector
terminal No.1 or G-19 licence plate lamp (LH)
connector terminal No.1 to body earth, or A-39
position lamp (RH) connector terminal No.1 or
A-17 position lamp (LH) connector terminal
No.1to A-25 earth connector terminal No.2.

SYMPTOM PROCEDURES

SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR

54B-288

AC310404

AC310404

AE

Connectors: A-17, A-25 <LHD>

A-17

A-25

Harness side

A-25 (GR)

A-17 (GR)

AC310399

AC310399

AE

Connectors: A-17, A-25 <RHD>

A-17

A-25

Harness side

A-25 (GR)

A-17 (GR)

AC310401

Connector: A-39 <LHD>

Harness side

A-39 (GR)

AB

AC310396

Connector: A-39 <RHD>

Harness side

A-39 (GR)

AB

AC310223

Connectors: G-08, G-15, G-19

AC

Harness side

G-08

G-15

G-19

G-08

Harness side

G-15

Harness side

G-19

AC310220

AD

Connector: G-20

Harness side