Mitsubishi Grandis. Manual — part 577
DIAGNOSIS
CONTROLLER AREA NETWORK (CAN)
54D-406
connector terminal Nos.26 and 27
OK: 120
± 20 Ω
Q: Is the check result normal?
YES :
<Within 120
± 20 Ω> Go to Step 8 .
NO :
<Not within 120
± 20 Ω> Go to Step 3 .
STEP 3. Connector check: C-09 joint connector
(CAN2) and C-02 combination meter connector
CAUTION
The strand end of the twist wire should be within
10 cm from the connector. For details refer to
When checking the joint connector, ensure that its
wiring harness side is not damaged.
Q: Are the check result normal?
YES :
Go to Step 4.
NO :
Repair the connector, or replace the joint
connector. Then go to Step 2.
STEP 4. Resistance measurement at C-09 joint
connector (CAN2).
CAUTION
A digital multimeter should be used. For details
refer to
.
CAUTION
The test wiring harness should be used. For
details refer to
(1) Disconnect the connector, and measure at the
wiring harness side.
(2) Ignition switch: OFF (LOCK)
CAUTION
When measuring the resistance, disconnect the
negative battery terminal. For details refer to
(3) Ensure that the negative battery terminal is
disconnected.
(4) Resistance between C-09 joint connector (CAN2)
AC310613
BB
Connector: C-02 <LHD>
Harness side
AC310615
AU
Harness side
Connector: C-09 <LHD>
C-09 (GR)
AC209350
1
12
2
13
3
14
4
15
5
16
6
17
7
18
8
19
9
20
10
21
11
22
AC
Short pin
AC310615
AU
Harness side
Connector: C-09 <LHD>
C-09 (GR)
AC204740DD
Harness side: C-09
Test
harness
Test
harness
DIAGNOSIS
CONTROLLER AREA NETWORK (CAN)
54D-407
terminal Nos. 7 and 18
OK: 120
± 20 Ω
Q: Is the check result normal?
YES :
<Within 120
± 20 Ω> Go to Step 7 .
NO :
<Not within 120
± 20 Ω> Go to Step 5 .
STEP 5. Resistance measurement at C-09 joint
connector (CAN2) and C-02 combination meter
connector.
CAUTION
A digital multimeter should be used. For details
refer to
CAUTION
The test wiring harness should be used. For
details refer to
(1) Disconnect the joint connector (CAN2) and the
combination meter connector, and measure at
the wiring harness side.
(2) Ignition switch: OFF (LOCK)
CAUTION
When measuring the resistance, disconnect the
negative battery terminal. For details refer to
(3) Ensure that the negative battery terminal is
disconnected.
(4) Continuity between C-09 joint connector (CAN2)
terminal No.7 and C-02 combination meter
connector terminal No.24
OK: 2
Ω or less
(5) Continuity between C-09 joint connector (CAN2)
terminal No.18 and C-02 combination meter
AC310613
BB
Connector: C-02 <LHD>
Harness side
AC310615
AU
Harness side
Connector: C-09 <LHD>
C-09 (GR)
AC312553 AI
Harness side: C-09
Test
harness
Harness side: C-02
Test
harness
AC312553 AK
Harness side: C-09
Harness side: C-02
Test
harness
Test
harness
DIAGNOSIS
CONTROLLER AREA NETWORK (CAN)
54D-408
connector terminal No.23
OK: 2
Ω or less
CAUTION
Strictly observe the specified wiring harness
repair procedure. For details refer to
Q: Are the check result normal?
YES :
<All the voltages measure 2
Ω or less> Go
to Step 6 .
NO :
<Either or all of the voltages measure more
than 2
Ω> Repair the wiring harness
between joint connector (CAN2) and the
combination meter connector, and then go
to Step 2.
STEP 6. Resistance measurement at C-02
combination meter connector.
CAUTION
A digital multimeter should be used. For details
refer to
(1) Remove the combination meter, and measure at
the equipment side.
(2) Resistance between C-02 combination meter
connector terminal Nos. 23 and 24
OK: 120
± 20 Ω
Q: Is the check result normal?
YES :
<Within 120
± 20 Ω> Go to Step 2 .
NO :
<Not within 120
± 20 Ω> Replace the
combination meter, and then go to Step 2.
AC310613
BB
Connector: C-02 <LHD>
Harness side
AC204740
AC204740
AC204740
AC204740DS
Equipment side: C-02
Test
harness
DIAGNOSIS
CONTROLLER AREA NETWORK (CAN)
54D-409
STEP 7. Resistance measurement at C-125
intermediate connector and C-09 joint connector
(CAN2).
CAUTION
A digital multimeter should be used. For details
refer to
CAUTION
The test wiring harness should be used. For
details refer to
(1) Disconnect the joint connector (CAN2) and the
intermediate connector, and measure at the
wiring harness side.
(2) Ignition switch: OFF (LOCK)
CAUTION
When measuring the resistance, disconnect the
negative battery terminal. For details refer to
(3) Ensure that the negative battery terminal is
disconnected.
(4) Continuity between C-125 intermediate
connector terminal No.26 and C-09 joint
connector (CAN2) terminal No.4
OK: 2
Ω or less
(5) Continuity between C-125 intermediate
connector terminal No.27 and C-09 joint
AC310615
AU
Harness side
Connector: C-09 <LHD>
C-09 (GR)
AC310613
AD
Connector: C-125 <LHD>
AC312553
AC312553 AM
Harness side: C-09
Test
harness
Female side: C-125
Test harness
AC312553
AC312553 AO
Harness side: C-09
Test
harness
Female side: C-125
Test harness