Mitsubishi Grandis. Manual — part 155
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-82
Step 8. Check the wiring harness between C-217
power window relay connector terminal No.5 and
fusible link (5).
NOTE:
Prior to the wiring harness inspection, check
intermediate connectors C-125 and junction block
connector C-202, and repair if necessary.
• Check the power supply line for open circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
− How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
AC310623
Connector: C-217
AB
3
4
5
1
2
Junction block side
<LHD>
Junction block (Front view)
AC310618
Connector: C-217
3
4
5
1
2
Junction block side
<RHD>
Junction block (Front view)
AB
AC310613
AD
Connector: C-125 <LHD>
AC310628AB
Connector: C-125 <RHD>
AC310623
Connector: C-202
AC
<LHD>
Junction block (Front view)
Harness side
AC310618
Connector: C-202 <RHD>
Junction block (Front view)
C-202
AC
Harness side
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-83
Step 9. Resistance measurement at C-217 power
window relay connector.
(1) Remove the power window relay, and measure at
the junction block side.
(2) Resistance between C-217 power window relay
connector terminal No.3 and body earth.
OK: 2
Ω or less
Q: Is the check result normal?
YES :
Go to Step 11.
NO :
Go to Step 10.
Step 10. Check the wiring harness between C-217
power window relay connector terminal No.3 and
body earth.
NOTE: Prior to the wiring harness inspection, check
junction block connector C-205, and repair if
necessary.
• Check the earth wires for open circuit.
Q: Is the check result normal?
AC310623
Connector: C-217
AB
3
4
5
1
2
Junction block side
<LHD>
Junction block (Front view)
AC310618
Connector: C-217
3
4
5
1
2
Junction block side
<RHD>
Junction block (Front view)
AB
AC310506 BF
Connector C-217
(Junction block side)
3
4
5
1
2
AC310624
Connector: C-205, C-217
C-205
AK
C-217
C-217
C-205
3
4
5
1
2
Junction block side
<LHD>
Harness side
AC310619
Connector: C-205, C-217
C-205
AI
C-217
C-217
C-205
3
4
5
1
2
Junction block side
Harness side
<RHD>
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-84
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
− How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
Step 11. Connector check: C-219 ETACS-ECU
connector.
Q: Is the check result normal?
YES :
Go to Step 12.
NO :
Repair the defective connector.
AC310626
Connector: C-219
Junction block (Rear view)
<LHD>
AB
Junction block side
AC310620
Connector: C-219
Junction block
(Rear view)
<RHD>
AB
Junction block side
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-85
Step 12. Check the wiring harness between C-217
power window relay connector terminal No.4 and
F-05 power window main switch connector
terminal No.6.
NOTE:
Prior to the wiring harness inspection, check
intermediate connectors C-14 <RH drive vehicles>,
C-27 <LH drive vehicles> and junction block
connector C-202, and repair if necessary.
• Check the power supply line for open circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
− How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
AC310623
Connector: C-217
AB
3
4
5
1
2
Junction block side
<LHD>
Junction block (Front view)
AC310618
Connector: C-217
3
4
5
1
2
Junction block side
<RHD>
Junction block (Front view)
AB
AC311150
AB
Connector: F-05
Harness side
<LHD>
10
1
6
14
5
12
13
4
11
7
2
3
8
9
F-05(B)
AC310213
Connector: F-05
Harness side
<RHD>
10
1
6
14
5
12
13
4
11
7
2
3
8
9
F-05(B)
AB
AC310631
Connector: C-14 <RHD>
AG
AC310613
Connector: C-27 <LHD>
AJ
AC310623
Connector: C-202
AC
<LHD>
Junction block (Front view)
Harness side
AC310618
Connector: C-202 <RHD>
Junction block (Front view)
C-202
AC
Harness side
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.