Mitsubishi Grandis. Manual — part 15
DIAGNOSTIC TROUBLE CODE PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-57
TROUBLE JUDGMENT
The ETACS-ECU communicates with the power
window main switch through the SWS
communication lines. If there is any trouble in that
communication, diagnosis code No.05 will be set.
COMMENTS ON TROUBLE SYMPTOM
If the power window main switch, the ETACS-ECU or
the CAN bus line fails, this diagnosis code will be set.
POSSIBLE CAUSES
• Malfunction of the power window main switch
• Malfunction of the ETACS-ECU switch
Power Window Main Switch and SWS Communication Circuit <RHD>
POWER
WINDOW RELAY
ETACS-ECU
DIAGNOSIS
CONNECTOR
POWER WINDOW
MAIN SWITCH
FUSIBLE
LINK
5
CPU
Wire colour code
B : Black LG : Light green G : Green L : Blue
W : White Y : Yellow SB : Sky blue BR : Brown
O : Orange GR : Gray R : Red P : Pink V : Violet
FRONT
SIDE
DIAGNOSTIC TROUBLE CODE PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-58
• Malfunction of the CAN bus
DIAGNOSIS PROCEDURE
Step 1. MUT-III CAN bus diagnostics
Use the MUT-III to diagnose the CAN bus lines.
Q: Is the check result normal?
YES :
Go to Step 2.
NO :
Repair the CAN bus line (Refer to GROUP
54D
− Diagnosis
Step 2. Check whether the diagnosis code is
reset.
Check again if the diagnosis code is set.
(1) Erase the diagnosis code.
(2) Ignition switch: LOCK (OFF) position to ON
(3) On completion, check that the diagnosis code is
not reset.
Q: Is the diagnosis code set?
YES :
Go to Step 3.
NO :
Intermittent malfunction (Refer to GROUP
00
− How to Use
Troubleshooting/Inspection Service Points
).
Step 3. Pulse check
Check the input signal from the ignition switch.
OK: The MUT-III sounds or the voltmeter
needle fluctuates.
Q: Is the check result normal?
YES :
Go to Step 4.
NO :
Refer to inspection procedure A-2 "When
the ignition switch is at the LOCK (OFF)
position, the functions do not work normally.
Check the battery power supply circuit to
the ETACS-ECU
Step 4. Connector check: F-05 power window
main switch connector
Q: Is the check result normal?
YES :
Go to Step 5.
NO :
Repair the defective connector.
Step 5. Voltage measurement at the F-05 power
window main switch connector.
(1) Disconnect the connector, and measure at the
wiring harness side.
System switch
Check condition
Ignition switch (IG1) When turned from ACC to
ON
AC311150
AB
Connector: F-05
Harness side
<LHD>
10
1
6
14
5
12
13
4
11
7
2
3
8
9
F-05(B)
AC310213
Connector: F-05
Harness side
<RHD>
10
1
6
14
5
12
13
4
11
7
2
3
8
9
F-05(B)
AB
AC311150
AB
Connector: F-05
Harness side
<LHD>
10
1
6
14
5
12
13
4
11
7
2
3
8
9
F-05(B)
AC310213
Connector: F-05
Harness side
<RHD>
10
1
6
14
5
12
13
4
11
7
2
3
8
9
F-05(B)
AB
DIAGNOSTIC TROUBLE CODE PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-59
(2) Ignition switch: ON
(3) Voltage between F-05 power window main switch
connector terminal No.6 and body earth
OK: System voltage
Q: Is the check result normal?
YES :
Go to Step 14.
NO :
Go to Step 6.
Step 6. Connector check: C-217 power window
relay connector
Q: Is the check result normal?
YES :
Go to Step 7.
NO :
Repair the defective connector.
Step 7. Check the power window relay.
Refer to GROUP 42
− Door
.
Q: Is the check result normal?
YES :
Go to Step 8.
NO :
Replace the power window relay.
Step 8. Voltage measurement at C-217 power
window relay connector.
(1) Remove the power window relay, and measure at
the junction block side.
(2) Voltage between C-217 power window relay
connector terminal No.5 and body earth
OK: System voltage
Q: Is the check result normal?
YES :
Go to Step 10.
NO :
Go to Step 9.
AC310507BQ
Connector F-05
(Harness side)
10
1
6
14
5
12
13
4
11
7
2
3
8
9
AC310623
Connector: C-217
AB
3
4
5
1
2
Junction block side
<LHD>
Junction block (Front view)
AC310618
Connector: C-217
3
4
5
1
2
Junction block side
<RHD>
Junction block (Front view)
AB
AC310623
Connector: C-217
AB
3
4
5
1
2
Junction block side
<LHD>
Junction block (Front view)
AC310618
Connector: C-217
3
4
5
1
2
Junction block side
<RHD>
Junction block (Front view)
AB
AC310507BR
Connector C-217
(Junction block side)
3
4
5
1
2
DIAGNOSTIC TROUBLE CODE PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-60
Step 9. Check the wiring harness between C-217
power window relay connector terminal No.5 and
fusible link (5).
NOTE:
Prior to the wiring harness inspection, check
intermediate connectors C-125 and junction block
connector C-202, and repair if necessary.
• Check the power supply line for open circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
− How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
AC310623
Connector: C-217
AB
3
4
5
1
2
Junction block side
<LHD>
Junction block (Front view)
AC310618
Connector: C-217
3
4
5
1
2
Junction block side
<RHD>
Junction block (Front view)
AB
AC310613
AD
Connector: C-125 <LHD>
AC310628AB
Connector: C-125 <RHD>
AC310623
Connector: C-202
AC
<LHD>
Junction block (Front view)
Harness side
AC310618
Connector: C-202 <RHD>
Junction block (Front view)
C-202
AC
Harness side
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст