Mitsubishi Grandis. Manual — part 201
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-266
Inspection Procedure J-4: Vehicle speed-dependent unfolding function does not work normally.
CAUTION
Whenever the ECU is replaced, ensure that the
input and output signal circuits are normal.
COMMENTS ON TROUBLE SYMPTOM
The ETACS-ECU operates this function in
accordance with the input signals below.
• Ignition switch (IG1)
• Vehicle speed signal
If this function does not work normally, these input
signal circuit(s) or the ETACS-ECU may be
defective. In addition, it is possible that the function
except the vehicle speed-dependent unfolding
function has been set by using the customized
function.
POSSIBLE CAUSES
• Malfunction of ETACS-ECU
• Damaged harness wires and connectors
DIAGNOSTIC PROCEDURE
Step 1. Check the SWS monitor customized
function.
Check that "WING MIRROR" is set to "SPEED SEN
FUN" by using the customized function.
Q: Is the check result normal?
YES :
Go to Step 2.
NO :
Set "WING MIRROR" to "SPEED SEN
FUN" by using the customized function.
(Refer to
).
Step 2. Check the electric folding door mirrors
operation.
Check that the door mirror is folded and unfolded
with the remote controlled mirror switch when the
ignition switch is at ACC position.
Q: Is the check result normal?
YES :
Go to Step 3.
NO :
Refer to inspection procedure J-1 "The
electric retractable remote controlled door
mirrors does not work at all
Step 3. ECU check by using the SWS monitor.
Check that the power supply and earth lines to the
ETACS-ECU and the SWS communication lines are
normal.
• Ignition switch: ON
ECUS TO BE CHECKED
• ETACS ECU
OK: "OK" is displayed on the "ETACS ECU"
menu.
Q: Is the check result normal?
YES :
Go to Step 4.
NO :
Refer to Inspection Procedure A-3
"Communication with the ETACS-ECU is
not possible
SPEED SIGNAL
COMBINATION METER
CAN COMMUNICATION LINE
(CAN_L LINE)
CAN COMMUNICATION LINE
(CAN_H LINE)
INPUT SIGNAL
ETACS-ECU
INPUT SIGNAL
IGNITION SWITCH (IG1)
Vehicle Speed-Dependent Unfolding Function
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-267
Step 4. ETACS ANALOG data by using the SWS
monitor.
Check the ETACS-ECU signal related to the vehicle
speed-dependent unfolding function.
• Set the simulated vehicle speed at approximately
10 km/h.
OK: Normal condition is displayed.
Q: Is the check result normal?
YES :
Go to Step 5.
NO :
Refer to inspection procedure Q-25 "The
vehicle speed signal is not received
STEP 5. Retest the system.
Check that the vehicle speed-dependent unfolding
function works normally.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
− How to
Cope with Intermittent Malfunction
NO :
Replace the ETACS-ECU.
IGNITION KEY CYLINDER
ILLUMINATION LAMP
Inspection Procedure K-1: The ignition key cylinder illumination lamp does not illuminate/extinguish
normally.
CAUTION
Whenever the ECU is replaced, ensure that the
input and output signal circuits are normal.
COMMENTS ON TROUBLE SYMPTOM
The ETACS-ECU operates this function in
accordance with the input signals below.
<Vehicles without keyless entry system>
• Ignition switch (IG1)
• Driver's door switch
<Vehicles with keyless entry system>
• Ignition switch (IG1)
• Key reminder switch
• Driver's door switch
Item No.
Item name
Normal condition
Item 03
SPEED SENSOR
8
− 10 km/h
Ignition Key Cylinder Illumination Lamp Circuit
KEY
REMINDER SWITCH
IGNITION
SWITCH (IG1)
ETACS-ECU
Wire colour code
B : Black LG : Light green G : Green L : Blue W : White Y : Yellow SB : Sky blue
BR : Brown O : Orange GR : Gray R : Red P : Pink V : Violet
KEY CYLINDER
ILLUMINATION LAMP
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-268
• Interior lamp loaded signal
If this function does not work normally, these input
signal circuit(s), the ignition key cylinder illumination
lamp or the ETACS-ECU may be defective.
POSSIBLE CAUSES
• Malfunction of the key reminder switch
• Malfunction of the driver's door switch
• Malfunction of the ignition key cylinder
illumination lamp
• Malfunction of the ETACS-ECU
• Damaged harness wires and connectors
DIAGNOSIS PROCEDURE
Step 1. Check the operation of the interior lamp.
Check that the interior lamps illuminate and
extinguish normally.
Q: Is the check result normal?
YES :
Go to Step 2.
NO :
Refer to inspection procedure P-1 "The
interior lamps (room ramp, rear personal
lamps, door lamps, luggage compartment
lamp, key illumination lamp) does not
illuminate or extinguish normally
Step 2. ECU check by using the SWS monitor.
Check that the power supply and earth lines to the
ETACS-ECU and the SWS communication lines are
normal.
• Ignition switch: OFF
ECU TO BE CHECKED
• ETACS ECU
OK: "OK" is displayed on the "ETACS ECU"
menu.
Q: Is the check result normal?
YES :
Go to Step 3.
NO :
Refer to Inspection Procedure A-3
"Communication with the ETACS-ECU is
not possible
Step 3. SWS monitor data list
Check the SWS communication signal, which are
related to the ignition key cylinder illumination lamp.
<Selected item> ETACS ECU
• Ignition switch: OFF
• Driver's door: open
OK: Normal conditions are displayed for all
the items
Q: Are the check result normal?
Normal conditions are displayed for all the items.
<Vehicles without keyless entry system> :
Go to
Step 4.
Normal conditions are displayed for all the items.
<Vehicles with keyless entry system> :
Go to Step
Normal condition is not displayed for item No.30. :
Refer to inspection procedure Q-2 "The
ignition switch (IG1) signal is not received
."
Normal condition is not displayed for item No.32. :
Refer to inspection procedure Q-5 "The
driver's door switch signal is not received
<LH drive vehicles> or
<RH drive vehicles>."
Step 4. ETACS switch data by using the SWS
monitor
Check the ETACS-ECU communication signal, which
is related to the ignition key cylinder illumination
lamp.
• Ignition switch: OFF (key inserted)
OK: Normal condition is displayed.
Q: Is the check result normal?
YES :
Go to Step 5.
NO :
Refer to inspection procedure Q-11 "The
key reminder switch signal is not received
."
Item No.
Item name
Normal
condition
Item 30
IG SW(IG1)
OFF
Item 32
DR DOOR SW
ON
Item No.
Item name
Normal
condition
Item 03
KEY REMIN SW
OFF
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) USING SWS MONITOR
54C-269
Step 5. Connector check: C-308 key reminder
switch connector.
Q: Is the check result normal?
YES :
Go to Step 6.
NO :
Repair the defective connector.
Step 6. Check the bulb of the ignition key
cylinder illumination lamp.
Check the bulb of the ignition key cylinder
illumination lamp.
Q: Is the check result normal?
YES :
Go to Step 7.
NO :
Replace the bulb of the ignition key cylinder
illumination lamp.
Step 7. Connector check: C-221 ETACS-ECU
connector.
Q: Is the check result normal?
YES :
Go to Step 8.
NO :
Repair the defective connector.
AC310153AD
Connector: C-308 <LHD>
Harness side
AC310183
AD
Connector: C-308 <RHD>
Harness side
AC310626
Connector: C-221
Junction block (Rear view)
<LHD>
AC
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
Harness side
C-221(GR)
AC310620
Connector: C-221
Junction block
(Rear view)
<RHD>
AC
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
Harness side
C-221(GR)
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.