Mitsubishi Montero (1998+). Manual — part 18

of hardware.

Binding . . . . . 2 .. Suggest repair or replacement.

Coolant leak . . . A .. Require repair or replacement.

Disconnected . . . A .. Require repair or replacement.

Malfunctioning . . .. A . . ... ( 1) Require repair or

replacement.

Missing . . . . . C . . . Require replacement.

Restricted . . . .. A .. Require repair or replacement.

Seized . . . . .. A .. Require repair or replacement.

Vacuum leak . . . . A .. Require repair or replacement.

(1) - Includes inoperative, intermittent operation, or

failure to perform all functions.

HEATER CORES

HEATER CORE INSPECTION

Condition Code Procedure

Air flow obstruction . A .. Require repair or replacement.

Attaching hardware

broken . . . . . A ... Require repair or replacement

of hardware.

Attaching hardware

missing . . . . C . . .. Require replacement of

hardware.

Attaching hardware not

functioning . . . A .. Require repair or replacement

of hardware.

Connection leaking . .. A .. Require repair or replacement.

Corroded . . . . 1 .. Suggest repair or replacement.

Disconnected . . . A .. Require repair or replacement.

Fins damaged, affecting

performance . . . A .. Require repair or replacement.

Fins damaged, not

affecting performance .. .. . . No service suggested or

required.

Internal restrictions,

affecting performance .. A .. Require repair or replacement.

Leaking . . . . . A .. Require repair or replacement.

Missing . . . . . C . . . Require replacement.

HEATER HOSES

HEATER HOSE INSPECTION

Condition Code Procedure

Application incorrect ... B . . . Require replacement.

Connected incorrectly ... A . . . . . Require repair.

Corroded, not reusable .. 1 . . . Suggest replacement.

Cracked . . . . . A .. Require repair or replacement.

Hard (brittle) . . .. 1 .. Suggest repair or replacement.

Inner fabric (webbing)

damaged . . . . A . . . Require replacement.

Insufficient clamping

force, allowing hose to

leak . . . . ... A .. Require repair or replacement.

Leaking . . . . . A .. Require repair or replacement.

Maintenance intervals ... 3 . . . Suggest replacement.

Melted . . . . .. 1 .. Suggest repair or replacement.

Missing . . . . . C . . . Require replacement.

Outer covering damaged .. 1 . . . Suggest replacement.

Outer covering damaged to

the extent that the inner

fabric is visible . .. A . . . Require replacement.

Protective sleeves

damaged . . . . 2 . Suggest replacement of sleeves.

Protective sleeves

missing . . . . 2 . Suggest replacement of sleeves.

Restricted, affecting

performance . . . A .. Require repair or replacement.

Restricted, not affecting

performance . . . 2 .. Suggest repair or replacement.

Routed incorrectly . .. 2 . . . . . Suggest repair.

Safety clip missing . . C . . . Require replacement.

Spongy . . . . .. 1 .. Suggest repair or replacement.

Stripped . . . . A . . . Require replacement.

Surface cracks (dry-

rotted) . . . . 1 .. Suggest repair or replacement.

Swollen . . . . . B . . . Require replacement.

Threads damaged . . . A .. Require repair or replacement.

Threads stripped (threads

missing) . . . ... A . . . Require replacement.

Type incorrect . . .. 1 .. Suggest repair or replacement.

HIGH PRESSURE RELIEF VALVES (HPRV)

HIGH PRESSURE RELIEF VALVE (HPRV) INSPECTION

Condition Code Procedure

Inoperative . . . . A . . ... ( 1) Require repair or

replacement.

Leaking . . . . . A .. Require repair or replacement.

Missing . . . . . C . . . Require replacement.

Threads damaged . . . A .. Require repair or replacement.

Threads stripped (threads

missing) . . . ... A . . . Require replacement.

(1) - Inoperative includes intermittent operation or out of

OEM specification.

IDLERS

See TENSIONERS.

IN-LINE FILTERS

IN-LINE FILTER INSPECTION

Condition Code Procedure

Connection leaking . .. B .. Require repair or replacement.

Leaking . . . . . A .. Require repair or replacement.

Restricted . . . .. A . . . Require replacement.

Threads damaged . . . A .. Require repair or replacement.

Threads stripped (threads

missing) . . . ... A . . . Require replacement.

METAL FITTINGS

See

AIR CONDITIONING METAL LINES, HOSES AND FITTING ASSEMBLIES .

METAL LINES

See

AIR CONDITIONING METAL LINES, HOSES AND FITTING ASSEMBLIES .

MIX AND AIR CONTROL DOORS (BLEND DOORS)

See PLENUMS.

O-RINGS

O-RING INSPECTION

Condition Code Procedure

Leaking . . . . . A . . ... ( 1) Require repair or

replacement.

(1) - Require inspection of mating and sealing surface and

repair or replace as necessary.

ORIFICE TUBES

ORIFICE TUBE INSPECTION

Condition Code Procedure

Application incorrect ... B . . . Require replacement.

Bypassing internally . A .. Require repair or replacement.

Filter screen torn . .. A . . . Require replacement.

Installation incorrect .. B . . . . . Require repair.

Restricted . . . .. A .. Require repair or replacement.

PILOT-OPERATED ABSOLUTES (POAS)

PILOT-OPERATED ABSOLUTE (POA) INSPECTION

Condition Code Procedure

Connection damaged . .. B .. Require repair or replacement.

Fitting damaged . . . B .. Require repair or replacement.

Inoperative . . . . A . . ... ( 1) Require repair or

replacement.

Leaking . . . . . A .. Require repair or replacement.

Threads damaged . . . A .. Require repair or replacement.

Threads stripped (threads

missing) . . . ... A . . . Require replacement.

(1) - Inoperative includes intermittent operation or out of

OEM specification.

PLENUMS

PLENUM INSPECTION

Condition Code Procedure

Air control door

binding . . . . A ... Require repair or replacement

Air control door

broken . . . . . A .. Require repair or replacement.

Air control door

leaking . . . . A .. Require repair or replacement.

Air control door

seized . . . . . A .. Require repair or replacement.

Attaching hardware

broken . . . . . A ... Require repair or replacement

of hardware.

Attaching hardware

missing . . . . C . . .. Require replacement of

hardware.

Attaching hardware not

functioning . . . A ... Require repair or replacement

of hardware.

Cracked . . . . . 2 .. Suggest repair or replacement.

Drain hole restricted ... A . . . . . Require repair.

Drain plugged . . ... A . . . . . Require repair.

Duct disconnected . ... A .. Require repair or replacement.

Duct leaking . . . A .. Require repair or replacement.

Duct missing . . . C . . . Require replacement.

Duct restricted . . . A .. Require repair or replacement.

Leaking . . . . . A .. Require repair or replacement.

Noisy . . . . ... 2 . . Suggest cleaning or repair.

Odor . . . . . 2 . . Suggest cleaning or repair.

Restricted . . . .. A . Require cleaning, repair, or

replacement.

PRESSURE CONTROL VALVES

See:

* EVAPORATOR PRESSURE REGULATORS (EPRS)

* HIGH PRESSURE RELIEF VALVES (HPRV)

* PILOT-OPERATED ABSOLUTES (POAS)

* SUCTION THROTTLING VALVES (STVS)

* VALVES IN RECEIVER (VIRS)

PRESSURE SENSORS

See THERMISTORS AND PRESSURE SENSORS.

PULLEYS

PULLEY INSPECTION

Condition Code Procedure

Alignment incorrect . . B .. Require repair or replacement.

Application incorrect ... B . . . Require replacement.

Attaching hardware

broken . . . . . A ... Require repair or replacement

of hardware.

Attaching hardware

missing . . . . C . . .. Require replacement of

hardware.

Attaching hardware not

Была ли эта страница вам полезна?
Да!Нет
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности