Mitsubishi Montero (1998+). Manual — part 69
Fig. 4: Routing Timing/Water Pump Belt (Mirage - 1.8L)
Courtesy of Mitsubishi Motor Sales of America.
Fig. 5: Routing Accessory Drive Belts (Montero - 3.5L & Montero
Sport - 3.0L; Montero Sport - 2.4L Similar)
Courtesy of Mitsubishi Motor Sales of America.
Fig. 6: Routing Timing/Water Pump Belt (3000GT - DOHC)
Courtesy of Mitsubishi Motor Sales of America.
COOLING SYSTEM SPECIFICATIONS
COOLING SYSTEM SPECIFICATIONS
Application Specification
Coolant Replacement Interval . . . . 30,000 Miles Or 24 Months
Coolant Capacity (Includes Heater & Reserve Tank)
Diamante . . . . . . . . . . 10.0 Qts. (9.5L)
Eclipse . . . . . . . . . . .. 7.4 Qts. (7.0L)
Galant . . . . . . . . . . ... 7.4 Qts. (7.0L)
Mirage
1.5L . . . . . . . . . . ... 5.3 Qts. (5.0L)
1.8L . . . . . . . . . . ... 6.3 Qts. (6.0L)
Montero . . . . . . . . . . . 10.0 Qts. (9.5L)
Montero Sport
2.4L
With Rear Heater . . . . . . . . 9.5 Qts. (9.0L)
Without Rear Heater . . . . . . .. 8.5 Qts. (8.0L)
3.0L
With Rear Heater . . . . . . ... 10.6 Qts. (10.0L)
Without Rear Heater . . . . . . .. 9.5 Qts. (9.0L)
3000GT . . . . . . . . . . ... 8.5 Qts. (8.0L)
Pressure Cap
Except Eclipse 2.0L Non-Turbo . . . . . . .. 11-15 psi
Eclipse 2.0L Non-Turbo . . . . . . . . . 14-18 psi
Thermostat Opens
Diamante
1997
Starts To Open . . . . . . . . .. 180
F (82
C)
Fully Open . . . . . . . . . .. 203
F (95
C)
1998
Starts To Open . . . . . . . . .. 192
F (89
C)
Fully Open . . . . . . . . . .. 203
F (95
C)
Eclipse
2.0L Turbo & 2.4L
Starts To Open . . . . . . . . .. 180
F (82
C)
Fully Open . . . . . . . . . .. 203
F (95
C)
2.0L Non-Turbo
Starts To Open . . . . . . . . 195
F (90.5
C)
Fully Open . . . . . . . . . . 216
F (102
C)
Galant
Starts To Open . . . . . . . . . 180
F (82
C)
Fully Open . . . . . . . . . . 203
F (95
C)
Mirage
Starts To Open . . . . . . . 177-183
F (80.5-83.9
C)
Fully Open . . . . . . . . . . 203
F (95
C)
Montero
1997
Starts To Open . . . . . . . . .. 180
F (82
C)
Fully Open . . . . . . . . . .. 203
F (95
C)
1998
Starts To Open . . . . . . . . .. 190
F (88
C)
Fully Open . . . . . . . . . . 212
F (100
C)
Montero Sport
Starts To Open . . . . . . . 177-183
F (80.5-83.9
C)
Fully Open . . . . . . . . . . 203
F (95
C)
3000GT (SOHC)
Starts To Open . . . . . . . . . 180
F (82
C)
Fully Open . . . . . . . . . . 203
F (95
C)
3000GT (DOHC)
Starts To Open . . . . . . . . . 170
F (77
C)
Fully Open . . . . . . . . . . 194
F (90
C)
ELECTRIC COOLING FAN
COMPONENT TESTING
Radiator Fan Motor (Diamante)
1) Disconnect radiator fan motor connectors A39 and A40.
Ground fan motor connector A39 terminal No. 2 (Black wire). Using a
fused jumper wire, connect battery voltage to fan motor connector A39
terminal No. 1 (Blue/Black wire). See Fig. 7. See WIRING DIAGRAMS. Fan
motor should operate at low speed with no abnormal noises or
interferences. Repair or replace components as necessary.
2) Ground fan motor connector A39 terminal No. 2 (Black wire)
and connector A40 terminal No. 2 (Black wire). Using a fused jumper
wire, connect battery voltage to fan motor connector A39 terminal No.
1 (Blue/Black wire). See Fig. 7. See WIRING DIAGRAMS. Fan motor should
operate at medium speed with no abnormal noises or interferences.
Repair or replace components as necessary.
3) Ground fan motor connector A39 terminal No. 2 (Black wire)
and connector A40 terminal No. 2 (Black wire). Using 2 fused jumper
wires, connect battery voltage to fan motor connector A39 terminal No.
1 (Blue/Black wire) and to connector A40 terminal No. 1 (Green wire).
See Fig. 7. See WIRING DIAGRAMS. Fan motor should operate at high
speed with no abnormal noises or interferences. Repair or replace
components as necessary.
Fig. 7: Testing Radiator Fan Motor (Diamante)
Courtesy of Mitsubishi Motor Sales of America.
Radiator Fan Motor (Eclipse)
1) Disconnect radiator fan motor 4-pin connector. Ground fan