Mitsubishi Montero (1998+). Manual — part 201
Place front mode selector knob at defrost setting. Press
damper lever inward, in direction of arrow. See Fig. 3. Connect inner
cable of mode selector cable to damper lever. Secure outer wire of
selector cable with clip.
Fig. 3: Adjusting Front Mode Selector Cable
Courtesy of Mitsubishi Motor Sales of America.
FRONT TEMPERATURE CONTROL CABLE
Move front temperature control knob to extreme right (HOT)
position. Press blend-air damper lever completely downward, in
direction of arrow. See Fig. 4. Connect inner wire of temperature
control cable to damper lever. Secure outer wire of control cable with
clip.
Fig. 4: Adjusting Front Temperature Control Cable
Courtesy of Mitsubishi Motor Sales of America.
FRONT VENTILATION CONTROL CABLE
Turn cool air by-pass lever/knob to far right/clockwise
(closed position). See Fig. 5. Lever should slightly touch stopper.
Connect ventilation control cable, and secure with clip.
Fig. 5: Adjusting Front Ventilation Control Cable
Courtesy of Mitsubishi Motor Sales of America.
TROUBLE SHOOTING
BLOWER MOTOR
If blower motor will only run at high speed, check blower
motor resistor. See BLOWER MOTOR RESISTOR under TESTING.
INSUFFICIENT HEAT
Obstructed floor outlets or heater hoses. Bound or improperly
adjusted dampers. Improperly adjusted control cable. Plugged heater
core.
NO VENTILATION
Improper damper adjustment. Incorrect mode selector cable
installation. Improper duct connection, or duct damage.
TESTING
* PLEASE READ THIS FIRST *
WARNING: To avoid injury from accidental air bag deployment, read and
carefully follow all SERVICE PRECAUTIONS and DISABLING &
ACTIVATING AIR BAG SYSTEM procedures in AIR BAG RESTRAINT
SYSTEM article.
BLOWER SWITCH
Disconnect switch, and check continuity between indicated
terminals using ohmmeter. See BLOWER SWITCH CONTINUITY table. See
Fig. 6.
BLOWER SWITCH CONTINUITY TABLE
Switch Continuity Between
Position Terminal No.
Low . . . . . . . . . . . 1 & 8; 3 & 5
Medium-Low . . . . . . . . .. 1 & 8; 5 & 6
Medium-High . . . . . . .. 1 & 4; 1 & 8; 2 & 5
High . . . . . . . . . 1 & 4; 1 & 8; 5 & 7
Fig. 6: Identifying Blower Switch Terminals
Courtesy of Mitsubishi Motor Sales of America.
BLOWER MOTOR
Disconnect blower motor connector. Connect battery directly
to blower motor terminals. Ensure blower motor operates smoothly.
Reverse polarity, and ensure blower motor operates smoothly in reverse
direction. Replace blower motor if it does not function as specified.
BLOWER MOTOR RELAY
1) Remove blower motor relay from junction block, located
under hood on driver’s side fenderwell. Using ohmmeter, check
continuity between terminals No. 1 and 3. See Fig. 7. Continuity
should not be present.
2) Check continuity between terminals No. 2 and 4. Ensure
continuity is present. Connect 12-volt battery to terminals No. 2 and
4. See Fig. 7. Ensure continuity exists between terminals No. 1 and 3
with voltage applied. If continuity is not as specified, replace
relay.
Fig. 7: Identifying Blower Relay Terminals
Courtesy of Mitsubishi Motor Sales of America.
BLOWER MOTOR RESISTOR