Mitsubishi Montero (2002-2004). Manual — part 336
SYMPTOM PROCEDURES
TSB Revision
SWS SYMPTOM PROCEDURES
54Bb-391
SYMPTOM PROCEDURES
TSB Revision
SWS SYMPTOM PROCEDURES
54Bb-392
INSPECTION PROCEDURE K-1: Flasher Timer: Turn-signal lights do not flash when the turn-signal
light switch is operated.
NOTE: This troubleshooting procedure requires the
use of scan tool MB991502 and SWS monitor kit
MB991862. For details on how to use the SWS mon-
itor, refer to "How to use SWS monitor
Turn-signal Light Power Supply Circuit
AC204170
CONNECTOR : D-28
BB
AC204173
CONNECTORS : D-210, D-212, D-217, D-221
D-210
D-217
D-212
AW
D-221
SYMPTOM PROCEDURES
TSB Revision
SWS SYMPTOM PROCEDURES
54Bb-393
.
CIRCUIT OPERATION
• The turn-signal light switch sends any signal
through the column-ECU (incorporated in the col-
umn switch) to the ETACS-ECU. If the column-
ECU sends a turn-signal light switch "ON" signal
to the ETACS-ECU, the ETACS-ECU turns on the
flasher timer (incorporated in the ETACS-ECU),
thus causing the turn-signal lights to flash.
• The ETACS-ECU operates the turn-signal lights
according to the following signals:
• Ignition switch (IG1)
• Turn-signal light switch
.
TECHNICAL DESCRIPTION (COMMENT)
Is the turn-signal lights do not flash normally, the
input circuits from the switches described in "CIR-
CUIT OPERATION" or the ETACS-ECU may be
defective. If the hazard warning lights do not flash,
the power supply line to the ETACS-ECU (dedicated
to the turn-signal lights) may be defective.
.
TROUBLESHOOTING HINTS
• The column switch (turn-signal light and lighting
switch) may be defective
• The ETACS-ECU may be defective
• The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
DIAGNOSIS
Required Special Tools:
• MB991223: Harness Set
• MB991502: Scan Tool (MUT-II)
• MB991862: SWS monitor kit
STEP 1. Verify the hazard warning light operation.
Q: Does the hazard warning light work normally?
YES : Go to Step 7.
NO : Go to Step 2.
STEP 2. Verify the turn-signal light operation.
Q: Does either of the turn-signal lights illuminate?
YES (illuminates at only one side) : Go to Step 3.
NO (do not illuminate at all) : Go to Step 4.
AC204174
CONNECTOR : D-222
AE
SYMPTOM PROCEDURES
TSB Revision
SWS SYMPTOM PROCEDURES
54Bb-394
STEP 3. Check ETACS-ECU connector D-222, junction
block connectors D-210, D-212 and D-217 for loose,
corroded or damaged terminals, or terminals pushed back
in the connector.
Q: Are ETACS-ECU connector D-222, junction block
connectors D-210, D-212 and D-217 in good condition?
YES : Replace the ETACS-ECU. Verify that the turn-signal
lights illuminate normally.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
. Verify that the turn-signal lights illuminate
normally.
AC204191
CONNECTORS : D-210, D-212, D-217
D-210
AG
HARNESS SIDE
HARNESS SIDE
D-217
D-210
HARNESS SIDE
D-212
D-212
D-217
1
2
7 6
3
9
4
11
12
10
13
5
8
8
1
11 10
3
4
12
9
2
13
14
6 5
15
7
7 6 5
2 1
9 8
11 10
4 3
AC204174
CONNECTOR : D-222
AB
1
2
3
5
6
4
9 8
121110
13
15 14
16
17
7
19
20
18
JUNCTION BLOCK SIDE
D-222