Mitsubishi Montero (2002-2004). Manual — part 716

TSB Revision

DIAGNOSTIC TROUBLE CODE PROCEDURES

13Ac-561

STEP 5. Check for open circuit and short circuit to ground
between manifold differential pressure sensor connector
B-28 (terminal No. 3) and PCM connector D-135 (terminal
No. 97).
Q: Is the harness wire in good condition?

YES : Replace the PCM. Then go to Step 12.
NO : Repair it. Then go to Step 12.

AK200975

1

2

3

AB

HARNESS
CONNECTOR:
COMPONENT SIDE

CONNECTOR: B-28

B-28(B)

AK200947

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

CONNECTOR: D-135

HARNESS CONNECTOR:
COMPONENT SIDE

AB

PCM

D-135(GR)

TSB Revision

DIAGNOSTIC TROUBLE CODE PROCEDURES

13Ac-562

STEP 6. Check the continuity at manifold differential
pressure sensor harness side connector B-28.
(1) Disconnect the connector B-28 and measure at the harness

side.

(2) Measure the continuity between terminal No. 2 and ground.

• Should be less than 2 ohms.

Q: Is the continuity normal?

YES : Go to Step 9.
NO : Go to Step 7.

STEP 7. Check harness connector D-135 at PCM for
damage.
Q: Is the harness connector in good condition?

YES : Go to Step 8.
NO : Repair or replace it. Refer to GROUP 00E, Harness

Connector Inspection

P.00E-2

. Then go to Step 12.

AK200975

1

2

3

AB

HARNESS
CONNECTOR:
COMPONENT SIDE

CONNECTOR: B-28

B-28(B)

AK000201

1

2

3

AC

B-28 HARNESS
CONNECTOR:
COMPONENT SIDE

AK200947

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

CONNECTOR: D-135

HARNESS CONNECTOR:
COMPONENT SIDE

AB

PCM

D-135(GR)

TSB Revision

DIAGNOSTIC TROUBLE CODE PROCEDURES

13Ac-563

STEP 8. Check for open circuit and harness damage
between manifold differential pressure sensor connector
B-28 (terminal No. 2) and PCM connector D-135 (terminal
No. 96).
Q: Is the harness wire in good condition?

YES : Replace the PCM. Then go to Step 12.
NO : Repair it. Then go to Step 12.

STEP 9. Check harness connector D-135 at PCM for
damage.
Q: Is the harness connector in good condition?

YES : Go to Step 10.
NO : Repair or replace it. Refer to GROUP 00E, Harness

Connector Inspection

P.00E-2

. Then go to Step 12.

AK200975

1

2

3

AB

HARNESS
CONNECTOR:
COMPONENT SIDE

CONNECTOR: B-28

B-28(B)

AK200947

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

CONNECTOR: D-135

HARNESS CONNECTOR:
COMPONENT SIDE

AB

PCM

D-135(GR)

AK200947

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

CONNECTOR: D-135

HARNESS CONNECTOR:
COMPONENT SIDE

AB

PCM

D-135(GR)

TSB Revision

DIAGNOSTIC TROUBLE CODE PROCEDURES

13Ac-564

STEP 10. Check for harness damage between manifold
differential pressure sensor connector B-28 (terminal No.
3) and PCM connector D-135 (terminal No. 97).
Q: Is the harness wire in good condition?

YES : Go to Step 11.
NO : Repair it. Then go to Step 12.

AK200975

1

2

3

AB

HARNESS
CONNECTOR:
COMPONENT SIDE

CONNECTOR: B-28

B-28(B)

AK200947

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

CONNECTOR: D-135

HARNESS CONNECTOR:
COMPONENT SIDE

AB

PCM

D-135(GR)

Была ли эта страница вам полезна?
Да!Нет
6 посетителей считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности