Mitsubishi Montero (2002-2004). Manual — part 91
AUTO A/C DIAGNOSIS
TSB Revision
AUTOMATIC AIR CONDITIONING
55B-57
STEP 14. Check the flexible flat cable (FFC).
(1) The FCC is connected to the automatic air conditioning
control panel assembly. Check that the FCC connection is
contaminated with foreign material or loose (Refer to
(2) There should be continuity across the FFC terminals.
Q: Is the FFC normal?
YES : Go to Step 15.
NO : Repair the FFC. (Refer to
.) The
temperature control should work normally.
AC205264AB
AUTO A/C DIAGNOSIS
TSB Revision
AUTOMATIC AIR CONDITIONING
55B-58
STEP 15. Check the temperature adjustment switch.
Follow the table below to check the temperature adjustment
switch for continuity.
TEMPERATURE
ADJUSTMENT
SWITCH
POSITION
TESTER
CONNECTION
SPECIFIED
CONDITION
1
7
− 10
Less than 2 ohms
2
7
− 8, 7 − 10
Less than 2 ohms
3
7
− 8
Less than 2 ohms
4
6
− 7, 7 − 8
Less than 2 ohms
5
6
− 7, 7 − 8, 7 − 10 Less than 2 ohms
6
6
− 7, 7 − 10
Less than 2 ohms
7
6
− 7
Less than 2 ohms
8
4
− 7, 6 − 7
Less than 2 ohms
9
4
− 7, 6 − 7, 7 − 10 Less than 2 ohms
10
4
− 7, 6 − 7, 7 − 8, 7
− 10
Less than 2 ohms
11
4
− 7, 6 − 7, 7 − 8
Less than 2 ohms
12
4
− 7, 7 − 8
Less than 2 ohms
13
4
− 7, 7 − 8, 7 − 10 Less than 2 ohms
14
4
− 7, 7 − 10
Less than 2 ohms
15
4
− 7
Less than 2 ohms
16
2
− 7, 4 − 7
Less than 2 ohms
17
2
− 7, 4 − 7, 7 − 10 Less than 2 ohms
18
2
− 7, 4 − 7, 7 − 8, 7
− 10
Less than 2 ohms
19
2
− 7, 4 − 7, 7 − 8
Less than 2 ohms
20
2
− 7, 4 − 7, 6 − 7, 7
− 8
Less than 2 ohms
21
2
− 7, 4 − 7, 6 − 7, 7
− 8, 7 − 10
Less than 2 ohms
22
2
− 7, 4 − 7, 6 − 7, 7
− 10
Less than 2 ohms
23
2
− 7, 4 − 7, 6 − 7
Less than 2 ohms
24
2
− 7, 6 − 7
Less than 2 ohms
25
2
− 7, 6 − 7, 7 − 10 Less than 2 ohms
26
2
− 7, 6 − 7, 7 − 8, 7
− 10
Less than 2 ohms
AC205403
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
AB
AC205259
1
2
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
AB
AUTO A/C DIAGNOSIS
TSB Revision
AUTOMATIC AIR CONDITIONING
55B-59
Q: Is the check result normal?
YES : Replace the A/C-ECU. (Refer to
.) The
temperature control should work normally.
NO : Replace the automatic air conditioning control panel.
The temperature control should work normally.
27
2
− 7, 6 − 7, 7 − 8
Less than 2 ohms
28
2
− 7, 7 − 8
Less than 2 ohms
29
2
− 7, 7 − 8, 7 − 10 Less than 2 ohms
TEMPERATURE
ADJUSTMENT
SWITCH
POSITION
TESTER
CONNECTION
SPECIFIED
CONDITION
AUTO A/C DIAGNOSIS
TSB Revision
AUTOMATIC AIR CONDITIONING
55B-60
INSPECTION PROCEDURE 4: Blower does not Operate.
Blower Motor Circuit
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст