Mitsubishi Montero (2002-2004). Manual — part 258
SYMPTOM PROCEDURES
TSB Revision
SWS SYMPTOM PROCEDURES
54Bb-79
INSPECTION PROCEDURE C-1: Central Door Locking System: The central door lock system does not
work at all.
NOTE: This troubleshooting procedure requires the
use of scan tool MB991502 and SWS monitor kit
MB991862. For details on how to use the SWS mon-
itor, refer to "How to use SWS monitor
Central Door Lock Power Supply Circuit
SYMPTOM PROCEDURES
TSB Revision
SWS SYMPTOM PROCEDURES
54Bb-80
.
CIRCUIT OPERATION
• The ETACS-ECU controls the central door lock
system, locking or unlocking all the doors by acti-
vating the central door lock relay (built into the
ETACS-ECU). The ETACS-ECU uses inputs from
the following components:
• Driver's or passenger's door lock actuator
switch
• Driver's or passenger's door lock key cylinder
switch
• Door lock switch, which is incorporated in the
power window main switch or power window
sub switch (front RH)
.
TROUBLESHOOTING HINTS
• The ETACS-ECU may be defective
• The wiring harness or connectors may have
loose, corroded or damaged terminals, or termi-
nals pushed back in the connector
ACX02274
FUSIBLE LINK (2)
AF
BATTERY
FUSIBLE LINK
AC000758
CONNECTORS: D-25, D-28
AK
D-25
D-28
ACX02286
CONNECTOR: D-222
AC
JUNCTION BLOCK (REAR VIEW)
AC203774
CONNECTOR: H-10
AB
DRIVER'S DOOR
H-10
ACX02285
CONNECTORS: D-209, D-211, D-217
AK
D-211
D-209
D-217
JUNCTION BLOCK (FRONT VIEW)
SYMPTOM PROCEDURES
TSB Revision
SWS SYMPTOM PROCEDURES
54Bb-81
DIAGNOSIS
Required Special Tools:
• MB991223: Harness Set
• MB991502: Scan Tool (MUT-II)
• MB991862: SWS Monitor Kit
STEP 1. Use scan tool MB991502 to select "ECU COMM
CHK" on the SWS monitor display.
Check the following ETACS-ECU.
CAUTION
To prevent damage to scan tool MB991502, always turn the
ignition switch to the "LOCK" (OFF) position before con-
necting or disconnecting scan tool MB991502. Also con-
nect SWS monitor kit MB991862 after turning on scan tool
MB991502.
(1) Connect scan tool MB991502 to the data link connector
(16-pin).
(2) Connect SWS monitor kit MB991862 to the data link
connector (13-pin).
(3) Turn the ignition switch to the "LOCK" (OFF) position.
(4) Operate scan tool MB991502 according to the procedure
below to display "ECU COMM CHK."
1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "ECU COMM CHK".
(5) Scan tool MB991502 should show "OK" on the "ECU
COMM CHK" menu for the "ETACS ECU" menu.
Q: Is "OK" displayed on the "ETACS ECU" menu?
YES : Go to Step 2.
NO : Refer to Inspection Procedure A-3 "Communication
with ETACS-ECU is not possible
AC204222AB
16-pin
13-pin
MB991502
MB991862
SYMPTOM PROCEDURES
TSB Revision
SWS SYMPTOM PROCEDURES
54Bb-82
STEP 2. Check the battery power supply circuit to the
ETACS-ECU. Test at ETACS-ECU connector D-222.
(1) Disconnect ETACS-ECU connector D-222, and measure at
the junction block side.
(2) Measure the voltage between terminal 12 and ground.
• The measured value should be approximately 12 volts
(battery positive voltage).
Q: Is the measured voltage approximately 12 volts (battery
positive voltage)?
YES : Go to Step 5.
NO : Go to Step 3.
STEP 3. Check the ETACS-ECU connector D-222 for loose,
corroded or damaged terminals, or terminals pushed back
in the connector.
Q: Is the ETACS-ECU connector D-222 in good condition?
YES : Go to Step 4.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
. Verify that the central door locking system
should now works normally.
AC204174
CONNECTOR : D-222
AB
1
2
3
5
6
4
9 8
121110
13
15 14
16
17
7
19
20
18
JUNCTION BLOCK SIDE
D-222
ACX01570
19
20
1817 1615 141312 1110 9 8 7
6 5 4 3 2 1
AB
CONNECTOR D-222
(JUNCTION BLOCK SIDE)
AC204174
CONNECTOR : D-222
AB
1
2
3
5
6
4
9 8
121110
13
15 14
16
17
7
19
20
18
JUNCTION BLOCK SIDE
D-222