Mitsubishi Montero (2002-2004). Manual — part 738
13Ad-1
TSB Revision
SYMPTOM PROCEDURES
13Ad-2
.
INSPECTION PROCEDURE 1: Communication with Scan Tool Is Not Possible. (Comunication with All
Systems Is Not Possible.)
AK201152
WHITE
BLA
CK
BLA
CK
RED
RED
10
38
1
5
16
1
10
9
2
11
3
12
4
13
5
14
6
15
7
16
8
D-118
4
10
29
38
11
14 15 16
2 3
12 13
26
5 6 7 8 9
27 28
32 33
17 18 19 20 21 22 23 24
34
35
30
36
25
31
37
1
D-28
13
3
5
7
12
9
1
6
8
11
10
2
4
D-210
(MU801860)
DATA LINK
CONNECTOR
4
JUNCTION
BLOCK
FUSIBLE
LINK (2)
1
D-211
Data Link Connector Circuit
10
20A
AK200976
DATA LINK
CONNECTOR
AB
D-118(B)
CONNECTOR: D-118
AK201041AB
CONNECTOR: D-211
D-211(B)
TSB Revision
SYMPTOM PROCEDURES
13Ad-3
.
CIRCUIT OPERATION
• A battery positive voltage is applied on the data
link connector power terminal (terminal No. 16).
The ground terminals (terminal No. 4, No. 5) are
grounded to the vehicle body.
.
COMMENT
• The cause is probably a defect in power supply
system (including ground) for the on-board diag-
nostic test mode line.
.
TROUBLESHOOTING HINTS (The most likely
causes for this case: )
• Malfunction of the data link connector.
• Damaged harness wire.
DIAGNOSIS
STEP 1. Measure the power supply voltage at data link
connector D-118.
(1) Measure voltage between terminal No. 16 and ground.
• Voltage should be battery positive voltage.
Q: Is battery positive voltage (approximately 12 volts)
present?
YES : Go to step 2.
NO : Check harness connectors D-210, D-211, D-28 at
intermediate connector for damage, and repair or
replace as required. Refer to GROUP 00E, Harness
Connector Inspection
. If intermediate
connector D-210, D-211, D-28 are in good condition,
repair an open circuit between fusible link (2) and data
link connector D-118 (terminal No. 16). Then confirm
that the malfunction symptom is eliminated.
AK201041AC
CONNECTOR: D-210
D-210
AK201042
D-28
AB
CONNECTOR: D-28
AK201285
1 2 3 4 5 6
12
11
10
1516
14
13
9
7 8
AB
D-118(B)
CONNECTOR: D-118
HARNESS CONNECTOR:
COMPONENT SIDE
AKX01430
1 2 3 4 5 6 7 8
16
15
14
13
12
11
10
9
D-118 HARNESS
CONNECTOR:
COMPONENT SIDE
AN
TSB Revision
SYMPTOM PROCEDURES
13Ad-4
STEP 2. Check the continuity at data link connector D-118.
(1) Check for the continuity between terminal No. 4, No. 5 and
ground.
• Should be less than 2 ohms.
Q: Is the continuity normal?
YES : Replace the scan tool. Then confirm that the
malfunction symptom is eliminated.
NO : Repair an open circuit or harness damage between
data link connector D-118 (terminal No. 4, No. 5) and
ground. Then confirm that the malfunction symptom is
eliminated.
AK201285
1 2 3 4 5 6
12
11
10
1516
14
13
9
7 8
AB
D-118(B)
CONNECTOR: D-118
HARNESS CONNECTOR:
COMPONENT SIDE
AKX01431
1 2 3 4 5 6 7 8
16
15
14
13
12
11
10
9
D-118 HARNESS
CONNECTOR:
COMPONENT SIDE
AL
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст