Mitsubishi Montero (2002-2004). Manual — part 109
AUTO A/C DIAGNOSIS
TSB Revision
AUTOMATIC AIR CONDITIONING
55B-129
STEP 3. Replace the lock sensor.
Q: Does the air conditioning work normally?
YES : No action is necessary and testing is complete.
NO : Replace the A/C-ECU. (Refer to
.) Check
that the air conditioning works normally.
DATA LIST REFERENCE TABLE
M1554005100051
MUT-II SCAN
TOOL DISPLAY
ITEM
NO.
INSPECTION ITEM INSPECTION REQUIREMENT
NORMAL VALUE
A/M DAMPER
31
Air mixing damper
control motor
potentiometer
Ignition switch: ON Damper
position
Opening degree (%)
MAX. HOT
Approx. 100
MAX. COOL
Approx. 0
OUTSIDE TEMP 13
Outside air
temperature sensor
Ignition switch: ON
Outside air
temperature and
temperature
displayed on the
scan tool are
identical.
EVAP TEMP
21
Air thermo sensor
Ignition switch: ON
The temperature of
the air, which flows
through the
evaporator, and
temperature
displayed on the
scan tool are
identical.
AIR OUT POS
32
Mode selection
damper control
motor potentiometer
Ignition switch: ON Damper
position
Opening degree (%)
FACE
Approx. 0
FOOT
Approx. 50
FOOT/DEF.
Approx. 75
DEF.
Approx. 100
PHOTO SNSR
25
Photo sensor
Ignition switch: ON
Amount of incident
light is proportional
to voltage displayed
on the scan tool.
INSIDE TEMP
11
Inside air
temperature sensor
Ignition switch: ON
Inside air
temperature and
temperature
displayed on the
scan tool are
identical.
HEATER TEMP
15
heater water
temperature sensor
Ignition switch: ON
ON when heater
core wall
temperature is 30
°C
(86
°F) or higher.
AUTO A/C DIAGNOSIS
TSB Revision
AUTOMATIC AIR CONDITIONING
55B-130
ACTUATOR TEST REFERENCE
M1554005200058
CHECK AT ECU TERMINAL
M1554005400085
MUT-II SCAN TOOL
DISPLAY
ITEM NO.
INSPECTION ITEM
DRIVE CONTENT
A/M 0%
05
Air mix damper motor
Opening degree: approx.
0%
A/M 100%
07
Opening degree: approx.
100%
A/M 50%
06
Opening degree: approx.
50%
CLUTCH OFF
11
A/C compressor
OFF
CLUTCH ON
12
ON
DEF
10
Air outlet changeover damper
motor
DEF
FACE
08
FACE
FAN HI
04
Blower motor
HI
FAN LO
02
LO
FAN ME
03
ME
FAN OFF
01
OFF
FOOT
09
Air outlet changeover damper
motor
FOOT
FRESH
13
Inlet/outlet air changeover damper
motor
FRESH
RECIRC
14
RECIRCULATION
1
2 3 4 5 6
7 8
9 10
11 12 13 14 15 16 17 18 19 20
32 33 34
29
30 31
21 22 23 24 25 26 27 28
35 36
AC002694
TERMINAL
NO.
INSPECTION ITEM
INSPECTION CONDITION
NORMAL
CONDITION
1
Air mixing damper control motor When the air mix damper is moved to
the MAX. COOL position.
10 V
When the air mix damper is moved to
the MAX. HOT position.
0.5 V
2
Mode selection damper control
motor (FACE)
When the damper is moved to the
FACE position.
10 V
When the damper is moved to the
DEF position.
0.5 V
3
Inside/outside air changeover
damper motor (inside air)
When the damper flap is moving to
the inside air recirculation position.
0.5 V
When the damper flap is moving to
the outside air induction position.
10 V (when the
motor is stopped)
AUTO A/C DIAGNOSIS
TSB Revision
AUTOMATIC AIR CONDITIONING
55B-131
4
Inside/outside air changeover
damper motor (FRESH)
When the damper flap is moving to
the inside air recirculation position.
0 V (when the
motor is stopped)
When the damper flap is moving to
the outside air induction position.
0.5 V
5
Request signal for turning the A/
C compressor on
Dual pressure switch: OFF
System voltage
Dual pressure switch: ON
0 V
6
RV meter communication line
Ignition switch: ON
Hi: 4
− 5 V
Lo: 0
− 1 V
7
PCM communication line
When the A/C is off.
0 V
When the A/C (compressor) is
operating
System voltage
8
-
-
-
9
Lock sensor input
When the compressor is operating
0
− 0.75 V (pulse
signal)
10
Heater blower controller unit
output
When the blower is operating
0
− 3.5 V
(alternative
effective value)
11
Air mixing damper control motor When the air mix damper is moved to
the MAX. COOL position.
0.5 V
When the air mix damper is moved to
the MAX. HOT position.
10 V
12
Air outlet changeover damper
motor (DEF)
When the damper is moved to the
FACE position.
0.5 V
When the damper is moved to the
DEF position.
10 V
13
-
-
-
14
Blower relay
When the blower is stopped
System voltage
When the blower is operating
0 V
15
Rear defogger
Rear defogger: OFF
System voltage
Rear defogger: ON
0 V
16
RV meter communication line
Ignition switch: ON
Hi: 4
− 5 V
Lo: 0
− 1 V
17
RV meter communication line
Ignition switch: ON
Hi: 4
− 5 V
Lo: 0
− 1 V
18
RV meter communication line
shield
At all times
0 V
19
Diagnosis data output
Ignition switch: ON
0
⇔ Battery
positive voltage
20
A/C compressor relay input
When the A/C is off.
0 V
When the A/C (compressor) is
operating
System voltage
21
Potentiometer power supply
At all times
5 V
TERMINAL
NO.
INSPECTION ITEM
INSPECTION CONDITION
NORMAL
CONDITION
AUTO A/C DIAGNOSIS
TSB Revision
AUTOMATIC AIR CONDITIONING
55B-132
22
Outside air temperature sensor
input
When sensor section temperature is
25
°C (77°F) [4 kΩ]
1.9 V
23
Heater water temperature sensor
input
When sensor section temperature is
25
°C (77°F) [4 kΩ]
2.8 V
24
Air mixing damper control motor
potentiometer input
When the damper door has moved to
the MAX. HOT position.
0.7
− 1.3 V
25
ILL power supply
Lighting switch: ON
System voltage
26
A/C-ECU power supply (IG2)
Ignition switch: ON
System voltage
27
A/C-ECU power supply (ACC)
Ignition switch: ACC
System voltage
28
A/C-ECU power supply (back-
up)
At all times
System voltage
29
Sensors and potentiometers
ground
At all times
0 V
30
Air thermo sensor input
When sensor section temperature is
25
°C (77°F) [1.5 kΩ]
2.2 V
31
Photo sensor (+)
At luminous intensity of 100,000 lux
or more
1 V
32
Mode selection damper control
motor potentiometer input
When the damper has moved to the
DEF position.
0.7
− 1.3 V
33
DTC input
Ignition switch: ON
0 V
34
A/C compressor lock signal
(ignition signal)
Engine speed: 3,000 r/min
0.3
− 3.0 V
35
Illumination ground
At all times
0 V
36
Ground
At all times
0 V
TERMINAL
NO.
INSPECTION ITEM
INSPECTION CONDITION
NORMAL
CONDITION