Mitsubishi Eclipse. Manual — part 444
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-319
.
CIRCUIT OPERATION
• Power is supplied from the MFI relay (terminal
No. 4) to the right bank heated oxygen sensor
(rear) heater.
• The ECM (terminal No. 27) <M/T> or PCM (termi-
nal No. 27) <A/T> controls continuity to the right
bank heated oxygen sensor (rear) heater by turn-
ing the power transistor in the ECM <M/T> or
PCM <A/T> "ON" and "OFF."
.
BACKGROUND
• The ECM <M/T> or PCM <A/T> checks whether
the heater current is within a specified range
when the heater is energized.
.
DESCRIPTIONS OF MONITOR METHODS
Right bank heated oxygen sensor heater (rear) cur-
rent is out of specified range when engine coolant
temperature is over 20
°C (68°F).
.
MONITOR EXECUTION
Continuous
.
MONITOR EXECUTION CONDITIONS (Other
monitor and Sensor)
Other Monitor (There is no temporary DTC stored
in memory for the item monitored below)
• Not applicable
Sensor (The sensor below is determined to be
normal)
• Engine coolant temperature sensor
.
AK300075
RIGHT BANK
HEATED OXYGEN
SENSOR (REAR)
CONNECTOR: B-28
AB
B-28 (GR)
AK300121
MFI RELAY
CONNECTOR: A-18X
AB
A-18X
AK300091
CONNECTOR: C-51 <M/T>
ECM
AF
C-51 (GR)
AK300244
CONNECTOR: C-52 <A/T>
AC
PCM
C-52 (GR)
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-320
DTC SET CONDITIONS
Logic Flow Chart
.
Check Conditions
• 60 seconds have elapsed from the start of the
previous monitoring.
• Engine coolant temperature is higher than 20°C
(68
°F).
• While the right bank heated oxygen sensor (rear)
heater is on.
• Battery positive voltage is at between 11 and 16.5
volts.
Judgment Criteria
• Heater current of the right bank heated oxygen
sensor (rear) heater has continued to be lower
than 0.16 ampere or higher than 5.0 ampere for 4
seconds.
.
OBD-ll DRIVE CYCLE PATTERN
Refer to , Diagnostic Function
− OBD-ll Drive Cycle −
Procedure 6
.
.
TROUBLESHOOTING HINTS (The most likely
causes for this code to be set are: )
• Open or shorted right bank heated oxygen sen-
sor (rear) heater circuit harness damage, or con-
nector damage.
• Open circuit in right bank heated oxygen sensor
(rear) heater.
• ECM failed. <M/T>
• PCM failed. <A/T>
START
END
YES
YES
YES
YES
NO
NO
NO
NO
MALFUNCTION
GOOD
CONTINUOUS
FAILURE FOR 4secs
MONITORING
CONDITIONS
CURRENT < 0.16A
CURRENT > 5.0A
AK301443
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-321
DIAGNOSIS
Required Special Tool:
• MB991316: Test Harness
STEP 1. Check connector B-28 at the right bank heated
oxygen sensor (rear) for damage.
Q: Is the connector in good condition?
YES : Go to Step 2.
NO : Repair or replace it. Refer to GROUP 00E, Harness
Connector Inspection
. Then go to Step 12.
AK300429
1
2
3
4
RIGHT BANK
HEATED OXYGEN
SENSOR (REAR)
CONNECTOR: B-28
AB
B-28 (GR)
HARNESS CONNECTOR:
COMPONENT SIDE
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-322
STEP 2. Check the right bank heated oxygen sensor (rear).
(1) Disconnect right bank heated oxygen sensor (rear)
connector B-28 and connect test harness special tool,
MB991316, to the connector on the right bank heated
oxygen (rear) sensor side.
(2) Measure the resistance between heated oxygen sensor
connector terminal 1 (red clip) and terminal 3 (blue clip).
Standard value: 11
− 18 ohms [at 20°C (68°F)]
Q: Is the resistance between 11 and 18 ohms?
YES : Go to Step 3.
NO : Replace the right bank heated oxygen sensor (rear).
Then go to Step 12.
AK300429
1
2
3
4
RIGHT BANK
HEATED OXYGEN
SENSOR (REAR)
CONNECTOR: B-28
AB
B-28 (GR)
HARNESS CONNECTOR:
COMPONENT SIDE
AKX01624 AB
MB991316
HEATED
OXYGEN
SENSOR
EQUIPMENT
SIDE
CONNECTOR
BLUE
RED