Mitsubishi Eclipse. Manual — part 950
![](/vehicles/winoney/grold/thow/ndr.png)
WINDOW GLASS
TSB Revision
BODY
42-25
REMOVAL SERVICE POINTS
.
<<A>> LIFTGATE LOWER MOLDING REMOVAL
CAUTION
If liftgate lower molding has become warped, it should not
be reused.
Use special tool MB990449 to lever out the molding.
.
<<B>> LIFTGATE WINDOW GLASS REMOVAL
Remove the liftgate window glass using the same procedure as
for the windshield. (Refer to
.)
INSTALLATION SERVICE POINT
.
>>A<< WINDOW SPACER/GLASS STOPPER/LIFTGATE
WINDOW GLASS INSTALLATION
1. Use 3M
AAD Part number 8906 or equivalent. to degrease
the inside and outside edges of the liftgate window glass
and the surface of the body flange.
2. Install glass stopper so that it is bent toward inside the
liftgate window glass and is firmly sticked.
3. Install glass stopper on liftgate window glass at the same
place as glass stopper is installed on body flange
4. Apply primer and adhesive.
5. Install the glass in the same way as for the windshield.
(Refer to
.)
AC000461
MB990449
AB
AC001777
37 mm
(1.5 in)
16 mm
(0.6 in)
AC
GLASS END
LINE
AC003816AB
GLASS STOPPER
INSTALLATION HOLES
![](/vehicles/winoney/grold/thow/sel.png)
QUARTER WINDOW GLASS AND REGULATOR ASSEMBLY
TSB Revision
BODY
42-26
QUARTER WINDOW GLASS AND REGULATOR ASSEMBLY
GENERAL DESCRIPTION
M1422000100395
POWER WINDOWS
Power windows are used in all vehicles. When the
power window main switch is operated, the quarter
windows will open or close. This system has the fol-
lowing operations and features.
• A timer function has been provided so that when
all doors are closed and ignition is turned off, the
power window can be operated for 30 seconds
from the time the ignition is turned off.
• The power window main switch contains a
one-touch down switch that will automatically
open the quarter windows.
WINDOW GLASS DIAGNOSIS
INTRODUCTION TO WINDOW GLASS DIAGNOSIS
M1422006700265
If water leaks from the quarter window glass, causes
for these faults can include faults in the glass, weath-
erstrip or drain hole.
WINDOW GLASS DIAGNOSTIC TROUBLESHOOTING STRATEGY
M1422006800251
Use these steps to plan your diagnostic strategy. If
you follow them carefully, you will be sure that you
have exhausted most of the possible ways to find a
window glass fault.
1. Gather information from the customer.
2. Verify that the condition described by the
customer exists.
3. Find the malfunction by following the Symptom
Chart.
4. Verify malfunction is eliminated.
SYMPTOM CHART
M1422006900292
SYMPTOM PROCEDURES
INSPECTION PROCEDURE 1: Quarter Window Glass Water Leak
DIAGNOSIS
STEP 1. Check if the seal is faulty.
Q: Is the seal faulty?
YES :
Repair it, then go to Step 3.
NO :
Go to Step 2.
STEP 2. Check if the body flange is deformed.
Q: Is the body flange deformed?
YES :
Repair or replace it, then go to Step 3.
NO :
Go to Step 3.
STEP 3. Check symptoms.
Q: Is any water leaking?
YES :
Return to Step 1.
NO :
This diagnosis complete.
SYMPTOMS
INSPECTION PROCEDURE REFERENCE PAGE
Quarter window glass water leak
1
Quarter window malfunction
2
Water leak around quarter window glass edge
3
Water leak from quarter trim
4
Wind noise around quarter window
5
![](/vehicles/winoney/grold/thow/kale.png)
QUARTER WINDOW GLASS AND REGULATOR ASSEMBLY
TSB Revision
BODY
42-27
INSPECTION PROCEDURE 2: Quarter Window Malfunction
DIAGNOSIS
STEP 1. Check the quarter window installation
condition.
Q: Is the quarter window installation condition good?
YES :
Go to Step 2.
NO :
Adjust it. (Refer to
.) Then go to
Step 3.
STEP 2. Inspect the window regulator assembly.
Q: Is the window regulator assembly in good
condition?
YES :
Go to Step 3.
NO :
Repair or replace it, then go to Step 3.
STEP 3. Check symptoms.
Q: Does the quarter window operate correctly?
YES :
This diagnosis is complete.
NO :
Return to Step 1.
INSPECTION PROCEDURE 3: Water Leak around Quarter Window Glass Edge
DIAGNOSIS
STEP 1. Check the weatherstrip.
Q: Is the weatherstrip in good condition?
YES :
Go to Step 2.
NO :
Replace it, then go to Step 3.
STEP 2. Check quarter window glass fit
(alignment).
Q: Is the quarter window glass fit (alignment) correct?
YES :
Go to Step 3.
NO :
Adjust it. Refer to
. Then go to Step
STEP 3. Check symptoms.
Q: Is any water leaking?
YES :
Return to Step 1.
NO :
This diagnosis is complete.
INSPECTION PROCEDURE 4: Water Leak from Quarter Trim
DIAGNOSIS
STEP 1. Check the drain hole.
Q: Is the drain hole clogged?
YES :
Replace it, then go to Step 3.
NO :
Go to Step 2.
STEP 2. Check the waterproof cover.
Q: Is the waterproof cover in good condition?
YES :
Go to Step 3.
NO :
Repair or replace it, then go to Step 3.
STEP 3. Check symptoms.
Q: Is any water leaking?
YES :
Return to Step 1.
NO :
This diagnosis is complete.
![](/vehicles/winoney/grold/thow/tanend.png)
QUARTER WINDOW GLASS AND REGULATOR ASSEMBLY
TSB Revision
BODY
42-28
INSPECTION PROCEDURE 5: Wind Noise around Quarter Window
DIAGNOSIS
STEP 1. Check the weatherstrip for holding
condition.
Q: Is the weatherstrip holding firmly?
YES :
Go to Step 2.
NO :
Adjust fit of quarter window glass. Refer to
. Then go to Step 4.
STEP 2. Check the clearance.
Q: Is the clearance between the quarter window glass
and the rear rail weatherstrip holder proper?
YES :
Go to Step 3.
NO :
Adjust it. Refer to
. Then go to Step
STEP 3. Check the quarter window regulator
assembly.
Q: Is the quarter window regulator deformed?
YES :
Repair or replace it. then go to Step 4.
NO :
Go to Step 4.
STEP 4. Check symptoms.
Q: Has the wind noise been improved?
YES :
Return to Step 1.
NO :
This diagnosis complete.
POWER WINDOW DIAGNOSIS
INTRODUCTION TO POWER WINDOWS DIAGNOSIS
M1429002600159
The quarter window is controlled by the convertible
top control module. For troubleshooting, refer to
Electric Convertible Top Diagnosis
the power window main switch is operated, the quar-
ter window regulator motor operates and opens or
closes the quarter window.
A timer function has been provided to allow the quar-
ter windows to be opened or closed in 30 seconds
after the ignition switch is turned from "ON" to
"LOCK" (OFF) position when a door <LH> and <RH>
is closed (door switch is OFF).
If the following types of symptom occur, there may be
a fault.
• None of the quarter windows open or close.
• There are quarter windows that do not open or
close using the power window main switch.
• When parking there are quarter windows that do
not open using the convertible top switch.
• The windows cannot be opened or closed using
the power window main switch within 30 seconds
after the ignition switch is turned from "ON" to
"LOCK" (OFF) position.
POWER WINDOWS DIAGNOSTIC TROUBLESHOOTING STRATEGY
M1429002700156
Use these steps to plan your diagnostic strategy. If
you follow them carefully, you will be sure that you
have exhausted most of the possible ways to find a
power windows fault.
1. Gather information from customer.
2. Verify that the condition described by the
customer exists.
3. Find the malfunction by following the Symptom
Chart.
4. Verify malfunction is eliminated.
SYMPTOM CHART
M1429002800186
SYMPTOMS
INSPECTION
PROCEDURE
REFERENCE PAGE
None of the quarter windows open or close.
1
Only the quarter window <LH> does not open and close.
2
Only the quarter window <RH> does not open and close.
3
The quarter windows cannot be opened or closed by the power
window main switch within 30 seconds after the ignition switch is
turned from "ON" to "LOCK" (OFF) position. (However, this is
before the front doors <LH> and <RH> are opened.)
-
.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.