Mitsubishi Eclipse. Manual — part 553
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-755
STEP 2. Check evaporative emission purge solenoid for
leaks.
(1) Remove the battery.
(2) Remove the air intake hose. (Refer to GROUP 15, Air
Cleaner
.)
(3) Disconnect hose C from the evaporative emission purge
solenoid side, and connect a hand vacuum pump to the
nipple of the evaporative emission purge solenoid.
(4) Apply a pressure on the hand vacuum pump, and confirm
that air is maintained.
(5) Disconnect the hand vacuum pump, and connect hose C to
the evaporative emission purge solenoid.
Q: Is the evaporative emission purge solenoid in good
condition?
YES : Go to Step 3.
NO : Replace the evaporative emission purge solenoid.
Then go to Step 17.
AC106501
HOSE C
EVAPORATIVE
EMISSION
PURGE
SOLENOID
AD
<VEHICLES WITHOUT INTAKE MANIFOLD
TUNING SYSTEM>
AC106498
<VEHICLES WITH INTAKE MANIFOLD
TUNING SYSTEM>
AD
HOSE C
EVAPORATIVE
EMISSION
PURGE
SOLENOID
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-756
STEP 3. Check for leaks in the evaporator line hose A to
hose E <Vehicle without Intake Mnifold Tuning System> or
hose B, C, E <Vehicle with Intake Mnifold Tuning System>.
The leakage test with a hand vacuum pump on each hose
from hose A to hose E <vehicle without Intake Mnifold
Tuning System> or hose B, C, E <vehicle with Intake
Mnifold Tuning System>.
Q: Are the hoses in good condition?
YES : Go to Step 4.
NO : Replace the inferior hose. Then go to Step 17.
AC106521
HOSE E
HOSE D
HOSE A
AIR INTALE HOSE
EVAPORATIVE
EMISSION
PURGE
SOLENOID
HOSE C
HOSE B
<VEHICLES WITHOUT INTAKE MANIFOLD
TUNING SYSTEM>
AE
AC106522
<VEHICLES WITH INTAKE MANIFOLD
TUNING SYSTEM>
AC
EVAPORATIVE
EMISSION
PURGE
SOLENOID
EVAPORATIVE
EMISSION
PURGE
SOLENOID
HOSE B
HOSE C
HOSE C
HOSE E
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-757
STEP 4. Check the evaporative emission ventilation
solenoid using scan tool MB991958. (Actuator test item 29)
CAUTION
To prevent damage to scan tool MB991958, always turn the
ignition switch to the "LOCK" (OFF) position before con-
necting or disconnecting scan tool MB991958.
(1) Connect scan tool MB991958 to the data link connector.
(2) Disconnect the hose G from the evaporative emission
ventilation solenoid side.
(3) Connect the hand vacuum pump to the nipple of the
evaporative emission ventilation solenoid from which the
hoses have been disconnected.
(4) Turn the ignition switch to the "ON" position.
(5) Set scan tool MB991958 to actuator test mode for item 29:
Evaporative Emission Ventilation Solenoid. When the
evaporative emission ventilation solenoid is operated, apply
a pressure on the hand vacuum pump and confirm that air
is maintained.
(6) Turn the ignition switch to the "LOCK" (OFF) position, and
disconnect scan tool MB991958.
(7) Disconnect the hand vacuum pump, and connect hose G to
the evaporative emission canister.
Q: Is the evaporative emission ventilation solenoid in good
condition?
YES : Go to Step 5.
NO : Replace the evaporative emission ventilation
solenoid. Then go to Step 17.
AC303127
AB
MB991911
16-PIN
MB991827
MB991824
AC002030 AB
HOSE G
EVAPORATIVE EMISSION
VENTILATION SOLENOID
AC002031AB
EVAPORATIVE EMISSION
VENTILATION SOLENOID
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-758
STEP 5. Pressure test for evaporator line from hose F to
hose P.
(1) Remove the module bracket mounting bolts, and
disconnect hose G from the evaporative emission
ventilation solenoid side, and plug the hoses from which the
hoses have been disconnected.
(2) Confirm that the evaporative emission system pressure
pump (Miller number 6872A) is operating properly. Perform
the self-test as described in the manufacturer's instructions.
(3) Connect an evaporative emission system pressure pump to
the fuel filler neck.
(4) Pressure test the system to determine whether any leaks
are present.
NOTE: "Pressure test" in this procedure refers to the
I/M240 Simulation Test (8 simple steps) described in the
evaporative emission system pressure pump (Miller number
6872A) manufacturer's instructions located in the lid of the
pump box.
Q: Are the evaporator line in good condition?
YES : Go to Step 16.
NO : Go to Step 6.
STEP 6. Pressure test for evaporator line from hose I to
hose P.
(1) Disconnect hose I from the evaporative emission canister
side, and plug the hose from which the pipes have been
disconnected.
(2) Perform the pressure test again.
Q: Are the evaporator line in good condition?
YES : Go to Step 7.
NO : Go to Step 9.
AC002028 AB
HOSE G
AC000186
AC002036 AB
HOSE I
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.