Mitsubishi Eclipse / Eclipse Spyder (2000-2002). Service and repair manual — part 693

MANUAL A/C DIAGNOSIS

TSB Revision

HEATING AND AIR CONDITIONING

55-9

INSPECTION PROCEDURE 2: When the air outlet changeover control knob is moved to defroster or
defroster/foot position, the A/C or the inside/outside air changeover damper motor does not operate.

DIAGNOSIS

STEP 1. Check the defroster switch continuity.

Q: Is the defroster switch in good condition?

YES : Go to Step 2.
NO : Replace. Then go to Step 2.

STEP 2. Check each A/C part.
Refer to Inspection Procedure 1.

Q: Is the A/C operating properly?

YES : This diagnosis is complete. (If no malfunctions are not

found in all steps, an intermittent malfunction is
suspected. Refer to GROUP 00E, How to Use
Troubleshooting/Inspection Service Points

How to

Cope with Intermittent Malfunction

P.00-6

.)

NO : Go to Step 1.

INSPECTION PROCEDURE 3: When the A/C is operating, temperature inside the passenger
compartment does not decrease (cool air not emitted).

DIAGNOSIS

STEP 1. Check for refrigerant leaks.

Q: Is the refrigerant leaking?

YES : Repair. Then go to Step 6.
NO : Go to Step 2.

AIR OUTLET
CHANGEOVER
CONTROL KNOB
POSITION

TESTER
CONNECTION

SPECIFIED
CONDITION

DEFROSTER,
DEFROSTER/
FOOT

2-3

Less than two ohm

OTHER POSITION 1-3

Less than two ohm

AC001373

HEATER
CONTROL
ASSEMBLY

AB

MANUAL A/C DIAGNOSIS

TSB Revision

HEATING AND AIR CONDITIONING

55-10

STEP 2. Check the dual pressure switch operation.
(1) Remove the dual pressure switch connector and connect

the high/low pressure side terminals located on the harness
side as shown in the illustration.

(2) Install a gauge manifold to the high-pressure side service

valve of the refrigerant line. (Refer to

P.55-22

.)

(3) When the high/low pressure sides of the dual pressure

switch are at operation pressure (ON) and there is
continuity between the respective terminals.

Q: When the high/low pressure sides of the dual pressure

switch are at operation pressure (ON), is there
continuity between the respective terminals?
YES :
Go to Step 3.
NO : Replace the switch. Then go to Step 6.

STEP 3. Check the refrigerant-temperature switch
operation.

Q: When the A/C is off, check that there is continuity

between the refrigerant-temperature switch terminals. Is
the circuit open loop?
YES :
Replace the switch. Then go to Step 6.
NO : If less than 2 ohm, go to Step 4.

STEP 4. Measure the automatic compressor controller
terminal voltage.
Refer to

P.55-18

.

Q: Is the automatic compressor controller terminal voltage

in good condition?
YES :
Go to Step 5.
NO : Replace. Then go to Step 6.

ITEMS

SWITCH POSITION

OFF

ON

ON

OFF

Low-pressure side kPa
(psi)

221 (32.1)

196 (28.4)

High-pressure side
kPa (psi

2,354 (341.4) 2,942 (426.7)

AC001368 AB

HIGH/LOW
PRESSURE SIDE

LOW-PRESSURE
SIDE

HIGH-PRESSURE
SIDE

ON

OFF

ON

OFF

AC001372

REFRIGERANT
TEMPERATURE
SWITCH TERMINALS

AB

MANUAL A/C DIAGNOSIS

TSB Revision

HEATING AND AIR CONDITIONING

55-11

STEP 5. Measure the engine control module <M/T>/the
powertrain control module <A/T> terminal voltage.
(1) Refer to GROUP 13A, Diagnosis

Check at The Engine

Control Module (ECM) <M/T> or Powertrain Control Module
(PCM) <A/T> <2.4L engine>

P.13A-452

.

(2) Refer to GROUP 13B, Diagnosis

Check at The Engine

Control Module (ECM) <M/T> or Powertrain Control Module
(PCM) <A/T> <3.0L engine>

P.13B-531

.

Q: Is the voltage in good condition?

YES : Go to Step 6.
NO : Replace. Then go to Step 6.

STEP 6. Check symptoms.

Q: Is the cool air discharged?

YES : This diagnosis is complete. (If no malfunctions are not

found in all steps, an intermittent malfunction is
suspected. Refer to GROUP 00E, How to Use
Troubleshooting/Inspection Service Points

How to

Cope with Intermittent Malfunction

P.00-6

.)

NO : Go to Step 1.

INSPECTION PROCEDURE 4: Blower fan and motor does not turn.

DIAGNOSIS

STEP 1. Check the blower relay continuity.

Q: Is the blower relay continuity in good condition?

YES : Go to Step 2.
NO : Replace. Then go to Step 5.

BATTERY
VOLTAGE

TERMINAL NO.
TO BE
CONNECTED TO
BATTERY

TERMINAL NO.
TO BE
CONDUCTED

SUPPLIED

1-3

2-5

NOT SUPPLIED

-

1-3

AC001376AB

JUNCTION BLOCK

BLOWER RELAY

MANUAL A/C DIAGNOSIS

TSB Revision

HEATING AND AIR CONDITIONING

55-12

STEP 2. Check the blower fan and motor operation.
When battery voltage is applied between the terminals, check
that the motor operates.

Q: Is there any abnormal noise?

YES : Go to Step 3.
NO : Replace. Then go to Step 5.

STEP 3. Check the blower switch continuity.

Q: Is the blower switch continuity in good condition?

YES : Go to Step 4.
NO : Replace. Then go to Step 5.

STEP 4. Check the resistor resistance value.
Use an ohmmeter to measure the resistance between the
terminals as indicated below. Check that the measured value is
at the standard value.

Standard value:

Q: Is the measured value at the standard value?

YES : Go to Step 5.
NO : Replace. Then go to Step 5.

AC001377AB

SWITCH
POSITION

TESTER
CONNECTION
(CONNECTOR A)

SPECIFIED
CONDITION

0 (OFF)

-

Open circuit

1 (LO)

3-5

Less than two ohm

2 (ML)

1-3

Less than two ohm

3 (MH)

3-6

Less than two ohm

4 (HI)

3-4

Less than two ohm

AC001371

BLOWER SWITCH
ASSEMBLY

AB

MEASUREMENT TERMINAL

STANDARD VALUE

Between terminals 3 and 2 (LO)

2.3

Between terminals 3 and 4 (ML)

1.1

Between terminals 3 and 1 (MH)

0.4

AC001379AB