Mitsubishi Eclipse / Eclipse Spyder (2000-2002). Service and repair manual — part 693
MANUAL A/C DIAGNOSIS
TSB Revision
HEATING AND AIR CONDITIONING
55-9
INSPECTION PROCEDURE 2: When the air outlet changeover control knob is moved to defroster or
defroster/foot position, the A/C or the inside/outside air changeover damper motor does not operate.
DIAGNOSIS
STEP 1. Check the defroster switch continuity.
Q: Is the defroster switch in good condition?
YES : Go to Step 2.
NO : Replace. Then go to Step 2.
STEP 2. Check each A/C part.
Refer to Inspection Procedure 1.
Q: Is the A/C operating properly?
YES : This diagnosis is complete. (If no malfunctions are not
found in all steps, an intermittent malfunction is
suspected. Refer to GROUP 00E, How to Use
Troubleshooting/Inspection Service Points
−
How to
Cope with Intermittent Malfunction
.)
NO : Go to Step 1.
INSPECTION PROCEDURE 3: When the A/C is operating, temperature inside the passenger
compartment does not decrease (cool air not emitted).
DIAGNOSIS
STEP 1. Check for refrigerant leaks.
Q: Is the refrigerant leaking?
YES : Repair. Then go to Step 6.
NO : Go to Step 2.
AIR OUTLET
CHANGEOVER
CONTROL KNOB
POSITION
TESTER
CONNECTION
SPECIFIED
CONDITION
DEFROSTER,
DEFROSTER/
FOOT
2-3
Less than two ohm
OTHER POSITION 1-3
Less than two ohm
AC001373
HEATER
CONTROL
ASSEMBLY
AB
MANUAL A/C DIAGNOSIS
TSB Revision
HEATING AND AIR CONDITIONING
55-10
STEP 2. Check the dual pressure switch operation.
(1) Remove the dual pressure switch connector and connect
the high/low pressure side terminals located on the harness
side as shown in the illustration.
(2) Install a gauge manifold to the high-pressure side service
valve of the refrigerant line. (Refer to
.)
(3) When the high/low pressure sides of the dual pressure
switch are at operation pressure (ON) and there is
continuity between the respective terminals.
Q: When the high/low pressure sides of the dual pressure
switch are at operation pressure (ON), is there
continuity between the respective terminals?
YES : Go to Step 3.
NO : Replace the switch. Then go to Step 6.
STEP 3. Check the refrigerant-temperature switch
operation.
Q: When the A/C is off, check that there is continuity
between the refrigerant-temperature switch terminals. Is
the circuit open loop?
YES : Replace the switch. Then go to Step 6.
NO : If less than 2 ohm, go to Step 4.
STEP 4. Measure the automatic compressor controller
terminal voltage.
Refer to
.
Q: Is the automatic compressor controller terminal voltage
in good condition?
YES : Go to Step 5.
NO : Replace. Then go to Step 6.
ITEMS
SWITCH POSITION
OFF
→
ON
ON
→
OFF
Low-pressure side kPa
(psi)
221 (32.1)
196 (28.4)
High-pressure side
kPa (psi
2,354 (341.4) 2,942 (426.7)
AC001368 AB
HIGH/LOW
PRESSURE SIDE
LOW-PRESSURE
SIDE
HIGH-PRESSURE
SIDE
ON
OFF
ON
OFF
AC001372
REFRIGERANT
TEMPERATURE
SWITCH TERMINALS
AB
MANUAL A/C DIAGNOSIS
TSB Revision
HEATING AND AIR CONDITIONING
55-11
STEP 5. Measure the engine control module <M/T>/the
powertrain control module <A/T> terminal voltage.
(1) Refer to GROUP 13A, Diagnosis
−
Check at The Engine
Control Module (ECM) <M/T> or Powertrain Control Module
(PCM) <A/T> <2.4L engine>
.
(2) Refer to GROUP 13B, Diagnosis
−
Check at The Engine
Control Module (ECM) <M/T> or Powertrain Control Module
(PCM) <A/T> <3.0L engine>
.
Q: Is the voltage in good condition?
YES : Go to Step 6.
NO : Replace. Then go to Step 6.
STEP 6. Check symptoms.
Q: Is the cool air discharged?
YES : This diagnosis is complete. (If no malfunctions are not
found in all steps, an intermittent malfunction is
suspected. Refer to GROUP 00E, How to Use
Troubleshooting/Inspection Service Points
−
How to
Cope with Intermittent Malfunction
.)
NO : Go to Step 1.
INSPECTION PROCEDURE 4: Blower fan and motor does not turn.
DIAGNOSIS
STEP 1. Check the blower relay continuity.
Q: Is the blower relay continuity in good condition?
YES : Go to Step 2.
NO : Replace. Then go to Step 5.
BATTERY
VOLTAGE
TERMINAL NO.
TO BE
CONNECTED TO
BATTERY
TERMINAL NO.
TO BE
CONDUCTED
SUPPLIED
1-3
2-5
NOT SUPPLIED
-
1-3
AC001376AB
JUNCTION BLOCK
BLOWER RELAY
MANUAL A/C DIAGNOSIS
TSB Revision
HEATING AND AIR CONDITIONING
55-12
STEP 2. Check the blower fan and motor operation.
When battery voltage is applied between the terminals, check
that the motor operates.
Q: Is there any abnormal noise?
YES : Go to Step 3.
NO : Replace. Then go to Step 5.
STEP 3. Check the blower switch continuity.
Q: Is the blower switch continuity in good condition?
YES : Go to Step 4.
NO : Replace. Then go to Step 5.
STEP 4. Check the resistor resistance value.
Use an ohmmeter to measure the resistance between the
terminals as indicated below. Check that the measured value is
at the standard value.
Standard value:
Q: Is the measured value at the standard value?
YES : Go to Step 5.
NO : Replace. Then go to Step 5.
AC001377AB
SWITCH
POSITION
TESTER
CONNECTION
(CONNECTOR A)
SPECIFIED
CONDITION
0 (OFF)
-
Open circuit
1 (LO)
3-5
Less than two ohm
2 (ML)
1-3
Less than two ohm
3 (MH)
3-6
Less than two ohm
4 (HI)
3-4
Less than two ohm
AC001371
BLOWER SWITCH
ASSEMBLY
AB
MEASUREMENT TERMINAL
STANDARD VALUE
Ω
Between terminals 3 and 2 (LO)
2.3
Between terminals 3 and 4 (ML)
1.1
Between terminals 3 and 1 (MH)
0.4
AC001379AB
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.