Mitsubishi Galant (2004+). Manual — part 448
DIAGNOSIS
TSB Revision
CONTROLLER AREA NETWORK (CAN)
54C-403
STEP 4. Check the CAN bus lines (communication line
including the combination meter) between joint connector
(3) and the combination meter. Measure the resistance at
joint connector (3) C-02.
CAUTION
A digital multimeter should be used. For details refer to
CAUTION
The test wiring harness should be used. For details refer to
(1) Disconnect joint connector (3) C-02, and measure the
resistance at the wiring harness side of joint connector (3)
C-02.
(2) Turn the ignition switch to the "LOCK" (OFF) position.
CAUTION
Disconnect the negative battery terminal. For details refer
to
.
(3) Disconnect the negative battery terminal.
(4) Measure the resistance between joint connector (3)
terminals 4 and 15.
OK: 120
± 20 Ω
Q: Does the resistance measure 120
± 20 Ω?
YES : If the resistance measures 120
± 20 Ω, go to Step 7.
NO : If the resistance does not measure 120
± 20 Ω, go to
Step 5 .
AC305231AP
CONNECTOR: C-02
AC209438
11
22
10
21
9
20
8
19
7
18
6
17
5
16
4
15
3
14
2
13
1
12
TEST
HARNESS
AX
TEST
HARNESS
HARNESS SIDE: C-02
DIAGNOSIS
TSB Revision
CONTROLLER AREA NETWORK (CAN)
54C-404
STEP 5. Check the CAN bus lines (communication line
only) between joint connector (3) and the combination
meter. Measure the resistance at joint connector (3) C-02
and combination meter connector C-101.
CAUTION
A digital multimeter should be used. For details refer to
CAUTION
The test wiring harness should be used. For details refer to
(1) Disconnect joint connector (3) C-02 and combination meter
connector C-101, and measure the resistance between
each wiring harness side connector.
(2) Turn the ignition switch to the "LOCK" (OFF) position.
CAUTION
Disconnect the negative battery terminal. For details refer
to
.
(3) Disconnect the negative battery terminal.
AC305232
HARNESS SIDE
C-101
CONNECTORS: C-02, C-101
AE
C-02
C-02
C-101
DIAGNOSIS
TSB Revision
CONTROLLER AREA NETWORK (CAN)
54C-405
(4) Measure the resistance between joint connector (3)
terminal 15 and combination meter connector terminal 15.
OK: 2 ohms or less
(5) Measure the resistance between joint connector (3)
terminal 4 and combination meter connector terminal 14.
OK: 2 ohms or less
CAUTION
Strictly observe the specified wiring harness repair proce-
dure. For details refer to
Q: Do all the resistances measure 2 ohms or less?
YES : If all the resistances measure 2 ohms or less, go to
Step 6.
NO : If either of the resistances measures more than 2
ohms or all the resistances measure more than 2
ohms, repair the wiring harness between joint
connector (3) and the combination meter connector,
and then go to Step 2.
AC204582
11
22
10
21
9
20
8
19
7
18
6
17
5
16
4
15
3
14
2
13
1
12
AC204582DB
HARNESS SIDE: C-02
TEST
HARNESS
G
G
22
11
5
16
19
20
21
17
18
8
10 9
7 6
13
1514
12
2
4 3
1
TEST
HARNESS
HARNESS SIDE: C-101
AC204582
HARNESS SIDE: C-02
TEST
HARNESS
DC
11
22
10
21
9
20
8
19
7
18
6
17
5
16
4
15
3
14
2
13
1
12
G
G
22
11
5
16
19
20
21
17
18
8
10 9
7 6
13
1514
12
2
4 3
1
TEST
HARNESS
HARNESS SIDE: C-101
DIAGNOSIS
TSB Revision
CONTROLLER AREA NETWORK (CAN)
54C-406
STEP 6. Check the terminator resistor inside the
combination meter. Measure the resistance at combination
meter connector C-101.
CAUTION
A digital multimeter should be used. For details refer to
(1) Disconnect combination meter C-101, and measure the
resistance at the component side of combination meter
connector C-101.
(2) Measure the resistance between combination meter
connector terminals 14 and 15.
OK: 120
± 20 Ω
Q: Does the resistance measure 120
± 20 Ω?
YES : If the resistance measures 120
± 20 Ω, go to Step 2.
NO : If the resistance does not measure 120
± 20 Ω,
replace the combination meter, and then go to Step 2.
AC305231AQ
CONNECTOR: C-101
HARNESS SIDE
AC204582BY
COMPONENT SIDE: C-101
G
11
22
17
3
14
G
12
1
13
2
15
4
16
5
18
7
6
19
8
10
21
20
9
TEST