Mitsubishi Galant 9G. Manual — part 1085
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.8L ENGINE>
13B-640
STEP 17. Check for harness damage between MFI relay
connector B-17X (terminal No. 4) and camshaft position
sensor connector B-106 (terminal No. 3).
Q: Is the harness wire in good condition?
YES : Go to Step 18.
NO : Repair it. Then go to Step 20.
1
2
3
4
AK303017
CONNECTOR: B-17X
FRONT OF VEHICLE
B-17X
AB
HARNESS
CONNECTOR:
COMPONENT SIDE
RELAY BOX
1
2
3
AK303130
HARNESS
CONNECTOR:
COMPONENT SIDE
AB
CAMSHAFT POSITION
SENSOR
B-106 (B)
CONNECTOR: B-106
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.8L ENGINE>
13B-641
STEP 18. Check for harness damage between camshaft
position sensor connector B-106 (terminal No. 2) and PCM
connector B-22 (terminal No. 104).
Q: Is the harness wire in good condition?
YES : Go to Step 19.
NO : Repair it. Then go to Step 20.
STEP 19. Check the camshaft position sensing cylinder.
Q: Is the camshaft position sensing cylinder in good
condition?
YES : Replace the camshaft position sensor. Then go to
Step 20.
NO : Repair it. Then go to Step 20.
STEP 20. Test the OBD-II drive cycle.
(1) Carry out a test drive with the drive cycle pattern. Refer to
Diagnostic Function
− OBD-II Drive Cycle − Procedure 6 −
(2) Check the diagnostic trouble code (DTC).
Q: Is DTC P0340 set?
YES : Retry the troubleshooting.
NO : The inspection is complete.
1
2
3
AK303130
HARNESS
CONNECTOR:
COMPONENT SIDE
AB
CAMSHAFT POSITION
SENSOR
B-106 (B)
CONNECTOR: B-106
AK303016
104
96
94
95
93 92 91
99 98 97
103 102 101 100
108 107 106 105
113 112 111 110 109
CONNECTOR: B-22
B-22 (B)
PCM
AB
HARNESS CONNECTOR:
COMPONENT SIDE
AIR CLEANER
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.8L ENGINE>
13B-642
DTC P0401: Exhaust Gas Recirculation Flow Insufficient Detected
.
TECHNICAL DESCRIPTION
• When the EGR valve (stepper motor) is actuated
from the fully closed position toward the open
position while the engine is running, EGR gas
flows.
• The PCM checks how the EGR gas flow signal
changes.
.
DESCRIPTIONS OF MONITOR METHODS
Small manifold pressure change during exhaust gas
recirculation (EGR) operation from closed to
open.
.
MONITOR EXECUTION
Continuous
.
MONITOR EXECUTION CONDITIONS
(Other monitor and Sensor)
Other Monitor (There is no temporary DTC stored
in memory for the item monitored below)
• EGR stepper motor monitor
Sensor (The sensor below is determined to be
normal)
• Mass airflow sensor
• Engine coolant temperature sensor
• Intake air temperature sensor
• Barometric pressure sensor
• Throttle position sensor
• Manifold absolute pressure sensor
• Accelerator pedal position sensor
.
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.8L ENGINE>
13B-643
DTC SET CONDITIONS
Logic Flow Chart
.
START
END
NO
NO
NO
YES
YES
YES
MALFUNCTION
GOOD
MONITORING
CONDITIONS
MEASURE MANIFOLD
PRESSURE (P1)
MEASURE MANIFOLD
PRESSURE (P2)
EGR VALVE OPEN
P2 - P1 < P0 *
SPECIFIED TIMES
AK204016
P0 : THRESHOLD VALUE