Mitsubishi Galant 9G. Manual — part 44
SYMPTOM PROCEDURES
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-172
.
CIRCUIT OPERATION
The ETACS-ECU turns on the power window relay
(installed on the junction block) to activate the power
windows when the ignition switch (IG1) is turned to
the "ON" position.
.
TROUBLESHOOTING HINTS
• The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
• The power window relay may be defective
• The power window main switch may be defective
• The ETACS-ECU may be defective
AC305015
FUSIBLE LINK No.5
AI
AC305231AB
CONNECTOR: C-26
AC305415AB
C-212
CONNECTORS: C-203, C-211,C-212,C-215
C-203
C-211
C-215
JUNCTION BLOCK
(FRONT VIEW)
AC305413AB
CONNECTOR: C-219
JUNCTION BLOCK
(REAR VIEW)
AC305262AB
CONNECTOR: E-12
SYMPTOM PROCEDURES
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-173
DIAGNOSIS
Required Special Tools:
• MB991223: Harness Set
• MB991958: Scan Tool (MUT-III Sub Assembly)
• MB991824: Vehicle Communication Interface (V.C.I.)
• MB991827: MUT-III USB Cable
• MB991910: MUT-III Main Harness A
• MB991813: SWS Monitor Kit
• MB991806: SWS Monitor Cartridge
• MB991812: SWS Monitor Harness (For Column-ECU)
• MB991822: Probe Harness
STEP 1. Use scan tool MB991958 to select "ECU COMM
Check" on the SWS monitor display.
Check the ETACS-ECU.
CAUTION
To prevent damage to scan tool MB991958, always turn the
ignition switch to the "LOCK" (OFF) position before con-
necting or disconnecting scan tool MB991958. Connect
special tool MB991910 before connecting special tool
MB991812. Be sure to connect special tool MB991806 after
turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
."
(2) Turn the ignition switch to the "ON" position.
(3) Operate the scan tool MB991958 according to the
procedure below to display "ECU COMM Check."
a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "ECU COMM Check."
(4) Scan tool MB991958 should show "OK" on the "ECU
COMM Check" menu for the "ETACS ECU" menu.
Q: Is "OK" displayed for the "ETACS ECU" menu?
YES : Go to Step 2.
NO : Refer to Inspection Procedure A-3 "Communication
with the ETACS-ECU is not possible
."
AC305411AB
MB991910
DATA LINK
CONNECTOR
MB991827
MB991824
MB991806
MB991812
AC302210
COLUMN SWITCH
CONNECTOR
COLUMN SWITCH
CONNECTOR AT
HARNESS SIDE
MB991812
AB
SYMPTOM PROCEDURES
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-174
STEP 2. Check the input signal by using "DATA LIST"
menu of the SWS monitor.
Turn the ignition switch to the "ON" position before checking
input signals from the ignition switch (IG1).
(1) Operate the scan tool MB991958 according to the
procedure below to display "ETACS ECU."
a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Data List."
f. Select "ETACS ECU."
(2) Check that normal conditions are displayed for the items
described in the table below.
Q: Does the scan tool MB991958 display "IG SW (IG1)" as
normal condition?
YES : Go to Step 3.
NO : Refer to Inspection Procedure M-2 "ETACS-ECU
does not receive any signal from the ignition switch
(IG1)
STEP 3. Check power window relay connector C-203 for
loose, corroded or damaged terminals, or terminals
pushed back in the connector.
Q: Is power window relay connector C-203 in good
condition?
YES : Go to Step 4.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
. The power windows function should now
work normally.
ITEM NO.
ITEM NAME
NORMAL CONDITION
ITEM 30
IG SW (IG1)
ON
AC305411AB
MB991910
DATA LINK
CONNECTOR
MB991827
MB991824
MB991806
MB991812
AC302210
COLUMN SWITCH
CONNECTOR
COLUMN SWITCH
CONNECTOR AT
HARNESS SIDE
MB991812
AB
AC305415 AC
JUNCTION BLOCK SIDE
CONNECTOR:C-203
JUNCTION BLOCK
(FRONT VIEW)
SYMPTOM PROCEDURES
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-175
STEP 4. Check the power window relay.
Q: Is the power window relay normal?
YES : Go to Step 5.
NO : Replace the power window relay. Verify that the
power windows work normally.
STEP 5. Check the battery power supply circuit to the
power window relay. Measure the voltage at power window
relay connector C-203.
(1) Disconnect power window relay connector C-203 and
measure the voltage available at the junction block side of
the connector.
(2) Measure the voltage between terminal 5 and ground.
• The voltage should measure approximately 12 volts
(battery positive voltage).
Q: Is the measured voltage approximately 12 volts (battery
positive voltage)?
YES : Go to Step 7.
NO : Go to Step 6.
BATTERY
CONNECTION
TESTER
CONNECTION
SPECIFIED
CONDITION
Not applied
4
− 5
Open circuit
• Connect terminal 1
to the positive
battery terminal
• Connect terminal 3
to the negative
battery terminal
4
− 5
Less than 2
ohms
AC305415 AC
JUNCTION BLOCK SIDE
CONNECTOR:C-203
JUNCTION BLOCK
(FRONT VIEW)
AC401493
1
3
4
5
1 2
4
5
3
AB
AC305415 AC
JUNCTION BLOCK SIDE
CONNECTOR:C-203
JUNCTION BLOCK
(FRONT VIEW)
1
2
3
4
5
AC201553
CONNECTOR: C-203
(JUNCTION BLOCK SIDE)
AE