Mitsubishi Galant 9G. Manual — part 284
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-212
NOTE: Also check intermediate connector C-29 and junction
block connector C-216 for loose, corroded, or damaged termi-
nals, or terminals pushed back in the connector. If intermediate
connector C-29, junction block connector C-216 is damaged,
repair or replace the connector as described in GROUP 00E,
Harness Connector Inspection
.
Q: Is the wiring harness between blower relay connector
C-202 (terminal 5) and fusible link (1) in good condition?
YES : It can be assumed that this malfunction is intermittent.
Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunctions
.
NO : Repair the wiring harness. The blower motor should
operate normally.
STEP 9. Check the wiring harness between blower relay
connector C-202 (terminal 3) and A/C-ECU connector C-15
(terminal 9).
AC305233
CONNECTOR: C-15
BG
C-105 (B)
HARNESS SIDE
AC305416
CONNECTORS: C-202, C-211
JUNCTION BLOCK
(FRONT VIEW)
JUNCTION BLOCK SIDE
C-202
C-202
AO
HARNESS SIDE
C-211
C-211
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-213
NOTE: Also check junction block connector C-211 for loose,
corroded, or damaged terminals, or terminals pushed back in
the connector. If junction block connector C-211 is damaged,
repair or replace the connector as described in GROUP 00E,
Harness Connector Inspection
.
Q: Is the wiring harness between blower relay connector
C-202 (terminal 3) and A/C-ECU connector C-15
(terminal 9) in good condition?
YES : Go to Step 10.
NO : Repair the wiring harness. The blower motor should
operate normally.
STEP 10. Check the wiring harness between blower motor
connector C-115 (terminal 1) and blower relay connector
C-202 (terminal 4).
Q: Is the wiring harness between blower motor connector
C-115 (terminal 1) and blower relay connector C-202
(terminal 4) in good condition?
YES : It can be assumed that this malfunction is intermittent.
Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunctions
.
NO : Repair the wiring harness. The blower motor should
operate normally.
STEP 11. Check the blower fan and motor operation.
When battery voltage is applied between the terminals, check
that the motor operates. Also, check that there is no abnormal
noise.
Q: Is there any abnormal noise?
YES : Go to Step 12.
NO : Replace the blower relay. The blower motor should
operate normally.
AC305233BN
CONNECTOR: C-115
HARNESS SIDE
AC305415BC
CONNECTOR: C-202
JUNCTION BLOCK SIDE
JUNCTION BLOCK
(FRONT VIEW)
AC209862
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-214
STEP 12. Check blower power transistor connector C-104
for loose, corroded or damaged terminals, or terminals
pushed back in the connector.
Q: Is power transistor connector C-104 in good condition?
YES : Go to Step 13.
NO : Repair or replace the connector. Refer to GROUP
00E, Harness Connector Inspection
.The
blower motor should operate normally.
STEP 13. Measure the resistance at power transistor
connector C-104.
(1) Disconnect power transistor connector C-104, and measure
the resistance at the wiring harness side.
(2) Measure the resistance value between terminal 2 and
ground.
• The measured value should be 2 ohms or less.
Q: Does the measured resistance value correspond with
this range?
YES : Go to Step 15.
NO : Go to Step 14.
STEP 14. Check the wiring harness between power
transistor connector C-104 (terminal 2) and ground.
Q: Is the wiring harness between power transistor
connector C-104 (terminal 2) and ground in good
condition?
YES : It can be assumed that this malfunction is intermittent.
Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunctions
.
NO : Repair the wiring harness. The blower motor should
operate normally.
AC305233
HARNESS SIDE
BV
CONNECTOR: C-104
AC305233
HARNESS SIDE
BV
CONNECTOR: C-104
AC209364JD
CONNECTOR C-104
(HARNESS SIDE)
AC305233
HARNESS SIDE
BV
CONNECTOR: C-104
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-215
STEP 15. Check the wiring harness between power
transistor connector C-104 (terminal 4) and blower motor
connector C-115 (terminal 2).
Q: Is the wiring harness between power transistor
connector C-104 (terminal 4) and blower motor
connector C-115 (terminal 2) in good condition?
YES : Go to Step 16.
NO : Repair the wiring harness. The blower motor should
operate normally.
STEP 16. Check the wiring harness between power
transistor connector C-104 (terminals 1 and 3) and
A/C-ECU connector C-15 (terminals 17 and 18).
Q: Are the wiring harness between power transistor
connector C-104 (terminals 1 and 3) and A/C-ECU
connector C-15 (terminals 17 and 18) in good condition?
YES : Go to Step 17.
NO : Repair the wiring harness. The blower motor should
operate normally.
AC305234
C-104
C-115
HARNESS SIDE
C-104
HARNESS SIDE
C-115
AR
CONNECTORS: C-104, C-115
AC305234
CONNECTORS: C-15, C-104
HARNESS SIDE
C-15
C-104
HARNESS SIDE
C-104
C-15 (B)
AS