Mitsubishi L200. Manual — part 712
HAZARD WARNING LAMP SWITCH
CHASSIS ELECTRICAL
54A-215
SYMPTOM PROCEDURES
Inspection Procedure 1: The hazard warning lamps do not illuminate.
CAUTION
Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.
COMMENTS ON TROUBLE SYMPTOM
If the hazard warning lamps do not illuminate, the
hazard warning lamp input signal circuit or the
ETACS-ECU may be defective.
PROBABLE CAUSES
• Malfunction of the hazard warning lamp switch
• Malfunction of the ETACS-ECU
• Damaged harness wires and connectors
DIAGNOSIS PROCEDURE
STEP 1. Check that the turn-signal lamps
operate.
Check that the turn-signal lamps illuminate normally.
Q: Is the check result normal?
YES :
Go to Step 2.
NO :
Refer to inspection procedure 11 "None of
the turn-signal lamps illuminate
STEP 2. M.U.T.-III diagnosis code.
When the electric motor switch is turned to the
"LOCK" (OFF) position, check that the ETACS-ECU
does not set the diagnosis code.
Q: Is the diagnosis code set?
Hazard Warning Lamp Circuit
ETACS-ECU
HAZARD
WARNING
LAMP SWITCH
TURN-SIGNAL
LAMP RELAY: LH
TURN-SIGNAL
LAMP RELAY: RH
INPUT SIGNAL
· FRONT TURN-SIGNAL
LAMP (LH)
· REAR TURN-SIGNAL
LAMP (LH)
· SIDE TURN-SIGNAL
LAMP (LH)
· COMBINATION METER
· FRONT TURN-SIGNAL
LAMP (RH)
· REAR TURN-SIGNAL
LAMP (RH)
· SIDE TURN-SIGNAL
LAMP (RH)
· COMBINATION METER
RELAY
BOX
FUSIBLE
LINK
23
Wire colour code
B : Black LG : Light green G : Green L : Blue W : White Y : Yellow SB : Sky blue
BR : Brown O : Orange GR : Grey R : Red P : Pink V : Violet PU : Purple
J/B SIDE
HAZARD WARNING LAMP SWITCH
CHASSIS ELECTRICAL
54A-216
YES :
Refer to diagnosis code chart
.
NO :
Go to Step 3.
STEP 3. Check the power supply circuit.
When the electric motor switch is at the "LOCK"
(OFF) position, check that the functions below work
normally.
• Lamp reminder function
• Central door locking system
Q: Is the check result normal?
YES :
Go to Step 4.
NO :
Refer to inspection procedure A-1 "Check
the battery power supply circuit to the
ETACS-ECU
."
STEP 4. M.U.T.-III data list
Check the input signal from the hazard warning lamp
switch.
• Operate the hazard warning lamp switch.
OK: Normal condition is displayed.
Q: Is the check result normal?
YES :
Go to Step 5.
NO :
Refer to inspection procedure 8 "The hazard
warning lamp switch signal is not received
."
STEP 5. Retest the system.
Check that the hazard warning lamps illuminate.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
− How to
use Troubleshooting/inspection Service
Points
− How to Cope with Intermittent
Malfunction ).
NO :
Replace the ETACS-ECU and register the
ID codes (Refer to
REMOVAL AND INSTALLATION
M1541501000035
Item
No.
Item name
Normal condition
26
Hazard warning lamp
switch
OFF to ON (only
when switch is
operated)
AC509437AB
1
2
3
HORN
CHASSIS ELECTRICAL
54A-217
INSPECTION
HAZARD WARNING LAMP SWITCH
CHECK
M1541501100032
HORN
REMOVAL AND INSTALLATION
M1542100200871
Removal steps
•
Centre upper box hood or RV meter
hood, lower panel assembly and
centre lower panel assembly (Refer
to GROUP 52A, Instrument Panel
Assembly ).
1.
Centre upper panel assembly
(Refer to GROUP 52A, Instrument
Panel Assembly ).
2.
Instrument panel switch holder
3.
Hazard warning lamp switch
Switch position
Tester
connection
Specified
condition
Released
1
− 2
Open circuit
Pressed
1
− 2
Continuity
(Less than 2
ohms)
AC503635
3 4
1 2
AB
AC900914 AB
1
2
21 ± 4 N·m
ACCESSORY SOCKET
CHASSIS ELECTRICAL
54A-218
INSTALLATION SERVICE POINT
>>A<< HORN (LO)/HORN (HI) INSTALLATION
Use the earth bolts as the mounting bolts for horn
(LO) and horn (HI). The earth bolts have "E" mark on
the bolt heads.
INSPECTION
HORN RELAY CONTINUITY CHECK
M1542100400552
ACCESSORY SOCKET
REMOVAL AND INSTALLATION
M1542300200499
Refer to GROUP 52A, Rear floor console assembly .
Removal Steps
•
Radiator grille (Refer to
GROUP 51, Radiator grille
.)
>>
A
1. Horn <LO>
>>
A
2. Horn <HI>
AC805322
Battery voltage
Tester
connection
Specified
condition
Not applied
3
− 4
Open circuit
• Connect terminal 2
to the positive
battery terminal
• Connect terminal 1
to the negative
battery terminal
Continuity
(2
Ω or less)
AC502554
AH
4
2
3
1
Horn relay
4
1
2
3
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.