Mitsubishi L200. Manual — part 863
Battery voltage Tester
connection
Specified
condition
Not applied
3
− 4
Open circuit
• Connect
terminal 1 to
the positive
battery
terminal
• Connect
terminal 2 to
the negative
battery
terminal
3
− 4
Continuity (Less
than 2
Ω)
ON-VEHICLE SERVICE
HEATER, AIR CONDITIONER AND VENTILATION
55A-68
IDLE-UP OPERATION CHECK
M1552001601846
1. Before inspection and adjustment, set vehicle in
the following condition:
• Engine coolant temperature: 80 − 90 °C
• Lamps, electric cooling fan and accessories: Set
to OFF
• Transmission: Neutral ("N" or "P" for vehicles with
A/T)
• Steering wheel: Straightforward
2. Check whether or not the idle speed is the
standard value.
Refer to GROUP 11A, On-vehicle Service
− Idle
Speed Adjustment .
Standard value:
650
± 50 r/min <High power engine>
700
± 50 r/min <Except high power engine>
3. When the A/C is running after turning the A/C
switch to ON, and the blower switch to the 3(MH)
or 4(HI) position, check to be sure that the idle
speed is at the standard value.
Standard value: 900
± 100 r/min
NOTE: It is not necessary to make an adjustment,
because the idling speed is automatically
adjusted by the ISC system. If, however, a devia-
tion from the standard value occurs for some rea-
son, check the ISC system.
REPLACE THE CLEAN AIR FILTER
<Vehicles with Clean air filter>
M1552020600466
AC904006
AB
1. Remove the glove box (Refer to GROUP 52A
−
Instrumental Panel, ).
2. Loosen the two screws as shown to replace the
clean air filter.
3. Install the glove box.
HEATER CONTROL ASSEMBLY AND A/C SWITCH
HEATER, AIR CONDITIONER AND VENTILATION
55A-69
HEATER CONTROL ASSEMBLY AND A/C SWITCH
REMOVAL AND INSTALLATION
M1552002400950
AC809536
3
4
5
6
8
7
1
2
AC
A
A
A
A
B B
C
C
D
D
E
E
Note
: Clip positions
: Claw positions
AC509709
Section A - A
Section B - B
Section E - E
Section D - D
Section C - C
AC
Clip
Instrument panel
7
Clip
Instrument panel
Clip
Instrument panel
Claw
Claw
7
1
7
1
1
7
Removal steps
1.
Centre lower panel
<<
A
>>
2.
Air selection lever knob
<<
B
>>
>>
C
<<
3.
Outside/Inside air selection damper
control cable connection
<<
B
>>
>>
B
<<
4.
Mode selection damper control
cable connection
<<
B
>>
>>
A
<<
5.
Air mixing damper control cable
connection
6.
Centre upper panel assembly
7.
Centre upper panel
8.
Heater control panel assembly
REMOVAL SERVICE POINTS
<<A>> AIR SELECTION LEVER KNOB REMOVAL
AC504107
AB
Claw
HEATER CONTROL ASSEMBLY AND A/C SWITCH
HEATER, AIR CONDITIONER AND VENTILATION
55A-70
Lift the claw, and remove the air selection lever knob.
<<B>> OUTSIDE/INSIDE AIR SELECTION
DAMPER CONTROL CABLE CONNECTION, AIR
MIXING DAMPER CONTROL CABLE
CONNECTION AND MODE SELECTION DAMPER
CONTROL CABLE CONNECTION REMOVAL
AC500229 AC
Sleeve
Clip
Cable
AC500239AC
Clip
Sleeve
Cable
AC
Sleeve
Clip
Cable
Always remove the cable by pressing the clip.
NOTE: When removing the cable, make sure that the
sleeve does not become misaligned.
INSTALLATION SERVICE POINTS
>>A<< AIR MIXING DAMPER CONTROL CABLE
CONNECTION
1. Set the Temperature control dial of the heater
control assembly to MAX HOT position.
Air mixing
damper lever
MAX HOT
position
MAX COOL
position
AB
Sleeve
2. Turn the air mixing damper lever of heater unit to
the MAX HOT position (Turn the damper lever to
the left until it stops.) and then install the cable.
3. Install the cable to the clip and fix it while aligning
the case.
NOTE: When installing the cable to the case,
make sure that the sleeve does not become mis-
aligned.
>>B<< MODE SELECTION DAMPER CONTROL
CABLE CONNECTION
1. Set the mode selection dial of the heater control
assembly to FOOT position.
AC500229
Air outlet changeover
damper lever
FACE
position
FOOT
position
AB
Sleeve
2. Turn the air outlet changeover damper lever of
heater unit to the DEF position (Turn the damper
lever to the left until it stops.) and then install the
cable.
3. Install the cable to the clip and fix it while aligning
the case.
NOTE: When installing the cable to the case,
make sure that the sleeve does not become mis-
aligned.
>>C<< OUTSIDE/INSIDE AIR SELECTION
DAMPER CONTROL CABLE CONNECTION
1. Set the air selection lever on the heater control
panel assembly to the inside recirculation.
AC500239
Inside
Outside
AB
Outside/Inside air
selection damper lever
Cable
Sleeve
HEATER CONTROL ASSEMBLY AND A/C SWITCH
HEATER, AIR CONDITIONER AND VENTILATION
55A-71
2. Set the outside/Inside air selection damper lever
of the heater blower assembly to the inside
position as shown in the illustration, and then
connect the cable to the link pin.
3. Install the cable to the clip and fix it while aligning
the case.
NOTE: When installing the cable to the case,
make sure that the sleeve does not become mis-
aligned.
INSPECTION
M1552002500355
BLOWER SWITCH CONTINUITY CHECK
AC500651
Switch
position
Tester connection
Specified
condition
OFF
1
− 3, 2 − 3, 3 − 4, 3 - 5 Open circuit
1
2
− 3
Continuity
(Less than
2
Ω)
2
1
− 3
3
3
− 4
4
3
− 5
DISASSEMBLY AND REASSEMBLY
M1552014200566
AC509725AB
3
4
1
2
8
6
5
7
Disassembly steps
1.
Knob
2.
Panel
3.
Blower switch
4.
Bulb
<<
A
>>
5.
Outside/inside air selection damper
control cable
<<
A
>>
6.
Mode selection damper control
cable
<<
A
>>
7.
Air mixing damper control cable
8.
Heater control
Disassembly steps (Continued)
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.